3.3 Naming conventions
Figure 1 shows the overall schema of the naming convention used for the characteristic Variables describing key control values.

Variables representing values coming in over the field bus from the Controller have BrowseNames according to the template string "<controllable variable name>CommandValue" (e.g. FrequencyCommandValue, PositionCommandValue, etc).
Setpoint values can be a combination of CommandValues and additive "CommandAdditiveValues" and represent the direct setpoint to the control algorithm. The BrowseNames of Variables representing additive values follow the naming convention <controllable variable name>CommandAdditiveValue, e.g. VelocityCommandAdditiveValue. Setpoint values have the naming convention <controllable variable name>Setpoint, e.g. VelocitySetpoint.
Variables representing an axis internal measured or calculated actual value have the naming convention <name of value>ActualValue, e.g. VelocityActualValue.