3.3 Naming conventions

Figure 1 shows the overall schema of the naming convention used for the characteristic Variables describing key control values.

Figure 1 - BrowseNames naming convention

Variables representing values coming in over the field bus from the Controller have BrowseNames according to the template string "<controllable variable name>CommandValue" (e.g. FrequencyCommandValue, PositionCommandValue, etc).

Setpoint values can be a combination of CommandValues and additive "CommandAdditiveValues" and represent the direct setpoint to the control algorithm. The BrowseNames of Variables representing additive values follow the naming convention <controllable variable name>CommandAdditiveValue, e.g. VelocityCommandAdditiveValue. Setpoint values have the naming convention <controllable variable name>Setpoint, e.g. VelocitySetpoint.

Variables representing an axis internal measured or calculated actual value have the naming convention <name of value>ActualValue, e.g. VelocityActualValue.

Variables representing a directly measured actual value provided by a sensor have the naming convention <name of value>FeedbackValue, e.g. PositionSensorFeedbackValue.