10.2 PtVibrationMeasurementVariableType

The PtVibrationMeasurementVariableType contains a standard vibration measurement value.

Table 69 - PtVibrationMeasurementVariableType definition
AttributeValue
BrowseNamePtVibrationMeasurementVariableType
IsAbstractFalse
ValueRank-1 (-1 = Scalar)
DataType0:Float
ReferencesNodeClassBrowseNameDataTypeTypeDefinitionOther
Subtype of the 0:AnalogUnitType defined in OPC 10000-8.
HasPropertyVariableTimeConstantFloat0:PropertyTypeO, RO
Conformance Units
Powertrain Actual and Command Values

The TimeConstant Property contains the time constant required and shall be provided if needed for comparability of calculated time series. The engineering unit used shall be seconds. It is assumed that the Variable Value is calculated out of the measurement values sampled in the time interval specified by the TimeConstant Property. For details of calculations refer to DIN ISO 20816.