10.2.2.2 PDRV Small Server Profile
Table 51 defines a Profile containing the minimum OPC UA functionality and PDRV Conformance Units any PROFINET Drives Server at least shall provide. Intended to be implemented by Servers on simple Devices.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| Profile | 0:Nano Embedded Device 2017 Server Profile http://opcfoundation.org/UA-Profile/Server/NanoEmbeddedDevice2017 | |
| Profile | 0:ComplexType 2017 Server Facet http://opcfoundation.org/UA-Profile/Server/ComplexTypes2017 | |
| Profile | 0:Data Access Server Facet http://opcfoundation.org/UA-Profile/Server/DataAccess | |
| PDRV | PDRV Measurement | M |
| PDRV | PDRV Axis Properties | M |
| PDRV | PDRV Logbook Readable | O |
| PDRV | PDRV Logbook Events | O |
| PDRV | PDRV Limit Events | O |
| PDRV | PDRV Security Roles | O |