7.8.2 CirculationSystemType ObjectType Definition
The CirculationSystemType provides a representation of a single circuit of the cooling system of a plasma surface treatment machine. An Instance of the PlantCoolingSystemType can have several Instances of the CirculationSystemsType as components. The CirculationSystemType is formally defined in Table 46.
| Attribute | Value | ||||
| BrowseName | CirculationSystemType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of the BaseObjectType defined in OPC 10000-5 | |||||
| 0:HasComponent | Variable | CoolingCircuitTemperatureOutlet | 0:Double | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | CoolingCircuitFlowRate | 0:Double | 0:AnalogUnitType | O, RO |
CoolingCircuitTemperatureOutlet is representing the temperature of the coolant at the outlet of the specific cooling circuit.
CoolingCircuitFlowRate is representing the volume flow of coolant through the specific cooling circuit.