7.10 HeatingSystemType ObjectType Definition

The HeatingSystemType provides all relevant Variables and parameters for monitoring a heating system of a plasma surface treatment machine. An overview of the information model is shown in Figure 18.

Figure 18 - HeatingSystemType overview

The HeatingSystemType is formally defined in Table 50.

Table 50 – HeatingSystemType Definition
Attribute Value
BrowseNameHeatingSystemType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the BaseObjectType defined in OPC 10000-5
0:HasAddInObject2:Identification4:MachineryComponentIdentificationTypeO
0:HasComponentObject4:Monitoring4:MonitoringTypeM
0:HasComponentObject4:MachineryBuildingBlocks0:FolderTypeM
Conformance Units
PST HeatingSystemType Basic
PST HeatingSystemType Advanced

Identification is used as defined in OPC 40001-1. Shall also be referenced as AddIn in the MachineryBuildingBlocks Folder.

Monitoring is representing a collection of the variables that are assigned to this specific component.

MachineryBuildingBlocks is representing a folder that directly references all those building blocks of the OPC UA for Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in in this specific component.

The components of the HeatingSystemType have additional references which are defined in Table 51.

Table 51 – HeatingSystemType Additional References
SourceBrowsePath Reference Type Is Forward TargetBrowsePath
4:MachineryBuildingBlocks0:HasAddInTrue2:Identification
4:MachineryBuildingBlocks0:HasAddInTrue4:Monitoring

The components of the HeatingSystemType have additional subcomponents which are defined in Table 52.

Table 52 – HeatingSystemType Additional Subcomponents
Source Path Reference NodeClass BrowseName DataType TypeDefinition Others
0:HasComponentVariableHeaterCurrent0:Double0:AnalogUnitTypeO, RO
0:HasComponentVariableHeaterVoltage0:Double0:AnalogUnitTypeO, RO
0:HasComponentVariableHeaterTemperature0:Double0:AnalogUnitTypeM, RO
0:HasComponentVariableHeaterPower0:Double0:AnalogUnitTypeO, RO

HeaterCurrent is representing the present current of the heater.

HeaterVoltage is representing the present voltage of the heater.

HeaterTemperature is representing the present temperature of the heater.

HeaterPower is representing the present power of the heater.