This Method is used as part of the PackMLMachineStateMachineType. It allows an OPC UA Client to change the state of this state machine to the Stopping state.
Signature
Stop(
);
Method result codes are defined in Table 36
Table 36 - Stop Method result codes
Result Code |
Description |
Bad_MethodInvalid |
See OPC 10000-4 – Services for the description of this result code. (The Method id does not refer to a Method for the specified Object.) |
Bad_NotImplemented |
See OPC 10000-4 – Services for the description of this result code. (Requested operation is not implemented.) |
Bad_NodeIdUnknown |
See OPC 10000-4 – Services for the description of this result code. (Used to indicate that the specified Object is not valid) |
Bad_InvalidState |
See OPC 10000-4 – Services for the description of this result code. (The operation cannot be completed because the Object is closed, uninitialized or in some other invalid state.) |
|
|
Table 37 specifies the AddressSpace representation for the Stop Method. Stop has no input or output parameters and has no referenced objects or variables.
Table 37 – Stop Method AddressSpace Definition
Attribute |
Value |
||||
BrowseName |
Stop |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
ModellingRule |
|
|
|
|
|
|
|
|
|
|
|
|