10.1 Conformance Units

This chapter defines the corresponding Conformance Units for the OPC UA Information Model for OPC UA for Weihenstephan Standards.

Table 28 – Conformance Units for OPC UA for Weihenstephan Standards
Category Title Description
ServerWeihenstephan WS MachineSupports the base functionality defined in OPC UA for Weihenstephan Standards Information Model. This includes all mandatory properties, the Object Identification and at least one of the optional FunctionalGroups.
ServerWeihenstephan Writable WS DataPointsSupports write access to all variables of the WS DataPoints, which are defined as writing according to the Weihenstephan Standards.
ServerWeihenstephan WSBaseObjectTypeThe server supports the WS BaseObjectType.
ServerWeihenstephan WSBaseStateMachineTypeThe server supports the BaseStateMachine. This include the list of AvailableStates and AvailableTransitions. It also includes all mandatory states and the mandatory sub-statemachines. The methods which are defined in PackML (See OPC 30050) do not have to be offered.
ServerWeihenstephan WSAnalogUnitTypeThe server supports the WSAnalogUnitType.
ServerWeihenstephan Engineering UnitsFor each data point of the instance WSAnalogUnitType an engineering unit is defined. If an engineering unit is not defined in UNECE Recommendations N° 20, the values in the EUInformation DataType must be filled in. See OPC 10000-8.
ServerWeihenstephan Corresponding WS TagNumbersIf the WSTagNumber is used in one of the following datatypes it must be ensured that the value is empty or belongs to the corresponding WS DataPoint: WSBaseObjectType, WSBaseStateMachineType and WSAnalogUnitType. Initial values like 0 are invalid values, MaxUInt16 (65535) might be a valid value.
ServerWeihenstephan WSAlarmTypeSupports the base WSAlarm type, and the mandatory component of the type.
ServerWeihenstephan WSAlarmCodeThe WSAlarmCode is of type Integer and is exchanged between server and client. The mapping of the WSAlarmCode to the corresponding error message is done on the client side. The mapping table is exchanged outside the Weihenstephan Standards. Ensure that a WSAlarmCode is mapped to the correct error message on both server and client side.
ClientWeihenstephan WSAlarmCodeThe WSAlarmCode is of type Integer and is exchanged between server and client. The mapping of the WSAlarmCode to the corresponding error message is done on the client side. The mapping table is exchanged outside the Weihenstephan Standards. Ensure that a WSAlarmCode is mapped to the correct error message on both server and client side.
ServerWeihenstephan WSAlarmMessageThe optional component WSAlarmMessage sends the error message directly to the client as localizedText. The descriptions of the alarm message from WSAlarmMessage and the mapped message from WSAlarmCode are identical.
ClientWeihenstephan WSAlarmMessageThe optional component WSAlarmMessage sends the error message directly to the client as localizedText. The descriptions of the alarm message from WSAlarmMessage and the mapped message from WSAlarmCode are identical.
ServerWeihenstephan WSWarningTypeSupports the WSWarning type, and the mandatory component of the type.
ServerWeihenstephan WSWarningCodeThe WSWarningCode is of type Integer and is exchanged between server and client. The mapping of the WSWarningCode to the corresponding warning message is done on the client side. The mapping table is exchanged outside the Weihenstephan Standards. Ensure that a WSWarningCode is mapped to the correct warning message on both server and client side.
ClientWeihenstephan WSWarningCodeThe WSWarningCode is of type Integer and is exchanged between server and client. The mapping of the WSWarningCode to the corresponding warning message is done on the client side. The mapping table is exchanged outside the Weihenstephan Standards. Ensure that a WSWarningCode is mapped to the correct warning message on both server and client side.
ServerWeihenstephan WSWarningMessageThe optional component WSWarningMessage sends the warning message directly to the client as localizedText. The descriptions of the warning message from WSWarningMessage and the mapped message from WSWarningCode are identical.
ClientWeihenstephan WSWarningMessageThe optional component WSWarningMessage sends the warning message directly to the client as localizedText. The descriptions of the warning message from WSWarningMessage and the mapped message from WSWarningCode are identical.
ServerWeihenstephan WSExecuteStateMachineTypeThe server supports the ExecuteStateMachine. This include the list of AvailableStates and AvailableTransitions. It also includes all mandatory states. The certification will include a list of all states and transitions supported by the StateMachine. This include the mandatory Sub-statemachines. All methods defined in the 4: PackMLExecuteStateMachineType (See OPC 30050) are not needed in this companien specification.
ServerWeihenstephan WSHeldStateMachineTypeThe server supports the HeldStateMachine. This include the list of AvailableStates and AvailableTransitions. It also includes all mandatory states. The certification will include a list of all states and transitions supported by the StateMachine