8.1 OperationType definition

The OperationType contains objects which are necessary to operate the DosingSystem. It is formally defined in Table 4. The top level of the OperationType describes the whole dosing system while detailed information about the single components can be found in the ComponentsType Object.

Figure 5 – OperationType Overview
Table 4 – OperationType Definition
Attribute Value
BrowseNameOperationType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC 10000-5
0:HasPropertyVariableIsActive0:Boolean0:PropertyTypeO, RO
0:HasComponentVariableSetActive0:Boolean0:BaseDataVariableTypeO, RW
0:HasComponentMethodIdentifyDeviceO
0:HasComponentMethodEnableDeviceM
0:HasComponentMethodDisableDeviceM
0:HasComponentVariableRemoteControlOpcUa0:Boolean0:BaseDataVariableTypeM
0:HasComponentVariableEnableDosingOpcUa0:Boolean0:BaseDataVariableTypeM
0:HasComponentMethodStartDosingShotO
0:HasComponentMethodStartDosingContinuousO
0:HasComponentMethodStopDosingO
0:HasComponentMethodStopDosingAfterCycleO
0:HasComponentObjectComponentsComponentsTypeM
0:HasComponentObjectThroughput4:ControlledParameterTypeO
0:HasComponentObjectShotWeight4:ControlledParameterTypeO
0:HasComponentVariableDosingDuration0:Duration0:BaseDataVariableTypeO, RW
0:HasComponentObjectMixingMixingTypeO
0:HasComponentObjectBatchWeight4:ControlledParameterTypeO
0:HasPropertyVariableHighestActiveAlarmSeverity0:UInt160:PropertyTypeM, RO
0:HasComponentVariableActiveErrors4:ActiveErrorDataType[]0:BaseDataVariableTypeM, RO
0:HasComponentMethodResetAllErrorsO
0:HasComponentMethodResetErrorByIdO
0:HasComponentMethodFirstFillingO
0:HasComponentMethodStartPurgeO
0:HasComponentVariablePurgeDuration0:Duration0:BaseDataVariableTypeO
0:HasComponentObjectElectricalEnergy4:EnergyTypeO
0:HasComponentObjectMaintenanceDosingMaintenanceTypeO
0:HasComponentObjectProductionDataSetManagement4:ProductionDatasetManagementTypeO
Conformance Units
OPC 40082-4 Basic