18.1 Conformance Units
This chapter defines the corresponding Conformance Unit for OPC 40082-4.
| Category | Title | Description |
| Server | OPC 40082-4 Basic | Support of DosingSystemType and all mandatory child elements giving information on the dosing system and its status. There is at least one instance of the DosingSystemType in the Machines Object. |
| Server | OPC 40082-4 Alarms | Support of HelpOffNormalAlarmType, providing error information. If this facet is supported and a client subscribes to the events, the server shall provide all errors via alarms in addition to the error variables included in the OperationType. |