11.6 FeedrateScalingFactor
Material-specific output of the Component per DrivePercentage.
Example:
A dosing screw with a maximum rotational speed of 300 rpm, the material output flow is 900 grams per second. 300 rpm means 100 % DrivePercentage. The Feedrate would then be 900/100 = 9 gram per % per second (g/(%*s))
Running at 50 % DrivePercentage, the output will be 50*9 = 450 g/s.
Example:
A vibrational feeder running at 50 Hz, the material output flow is 10 gram per second. The maximum frequency of the feeder is 250 Hz. 250 Hz equals 100 % DrivePercentage, 50 Hz equals 20 % DrivePercentage. The feederate is 10/20 = 0.5 gram per % per second (g/%/s).