8.9 StartDosingShot

If EnableDosingOpcUa is TRUE, this method can be used to start dosing for one shot with a defined duration specified by DosingDuration, no arguments.

If EnableDosingOpcUa is FALSE, the return statement shall be “Bad_InvalidState”

In case of inline dosing in a cyclic production process, this method needs to be called every cycle.

Signature

	StartDosingShot();
Table 8 – StartDosingShot Method AddressSpace Definition
Attribute Value
BrowseNameStartDosingShot
References Node Class BrowseName DataType TypeDefinition Modelling Rule

If StartDosingShot is used, DosingDuration becomes mandatory.