8.9 StartDosingShot
If EnableDosingOpcUa is TRUE, this method can be used to start dosing for one shot with a defined duration specified by DosingDuration, no arguments.
If EnableDosingOpcUa is FALSE, the return statement shall be “Bad_InvalidState”
In case of inline dosing in a cyclic production process, this method needs to be called every cycle.
Signature
StartDosingShot();| Attribute | Value | ||||
| BrowseName | StartDosingShot | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Modelling Rule |
|---|
If StartDosingShot is used, DosingDuration becomes mandatory.