OPC-30060 – OPC UA for Tobacco Machine Communication8.46.1 Overviewcontrol loop consisting of the desired value (SetPoint) for a measured value (ProcessValue) which is obtained by acting on an actuator (ControlValue). The ProcessControlLoopType is formally defined in the following ... Instance Declarations of that Node. 0:HasComponent Objects ControlValue ProcessControlItemType M 0:HasComponent Objects ProcessValue ProcessControlItemType M 0:HasComponent Objects SetPoint ProcessControlItemType O 0:HasProperty Variable WatchdogEnabled 0:Boolean
-
OPC-30142 – OPC UA for PROFINET Remote IOpotential for economic improvements. Providing Process Values as components of RIO Channel Objects and/or Process Value arrays or bit fields as components of RIO Channel Group Objects . Contribute data ... data obtained. Providing engineering unit and range information as Properties of Process Value Variables . Support Commissioning Plant operators switch selected channels into manual mode and enforce a certain process value
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Model The "RIOChannel" Object in the functional aspect aggregates Process Value Objects optionally offering additional information like Process Value qualifiers associated with the IO data. Figure ... Device . The "ProcessValue" Variable in Figure 8 contains an analog Process Value . The VariableType used to represent analog Process Values is RioPaAnalogProcessValueVariableType , the data type used by this
-
OPC-30142 – OPC UA for PROFINET Remote IOValue" and "02_AO_2_Value" are connected to the Process Value Variables with 0:RepresentsSameEntityAs References in the same way as described before. The qualifiers ... field. The Server may optionally provide additional RioFaProcessValueQualifierVariableType Variables as components of the Process Value Variables to make the status information directly accessible for Clients without decoding the value structure
-
OPC-30142 – OPC UA for PROFINET Remote IOProcess Value Qualifier and StatusCode Relationship When returning the Value of Process Values , the Server shall set the StatusCode member of the DataValue structures returned by the Read Service ... Publish Service consistent with the Process Value Qualifier information defined for Process Value Variables and structures
-
OPC-30142 – OPC UA for PROFINET Remote IOrestricted to NE 107 (See [ PCD ] chapter 5.4.3.2), the status information delivered for one Process Value and the OPC UA StatusCode shall be set consistent as defined in Table ... 0x3D, 0x3F BAD_FUNCTION_CHECK_ SIMULATION_ACTIVE Out of Specification (S) 0x78, 0x7A UNCERTAIN - process related, no maintenance Uncertain , 0x40000000 UNCERTAIN OUT_OF_ SPECIFICATION UNCERTAIN_NO_MAINTENANCE 0x79, 0x7B UNCERTAIN
-
OPC-30142 – OPC UA for PROFINET Remote IO6.8.1.2 Status with detailed Informationcodes with detailed information (See [ PCD ] chapter 5.4.3.3), the status information delivered for one Process Value and the OPC UA StatusCode shall be set consistent as defined in Table ... MAINTENANCE_ALARM 0x25, 0x27 BAD_MAINTENANCE_ALARM_ SIMULATION_ACTIVE Failure (F) 0x28, 0x2A BAD - process related, no maintenance Bad , 0x80000000 BAD FAILURE BAD_PROCESS 0x29, 0x2B BAD_PROCESS_SIMULATION_ACTIVE
-
OPC-30142 – OPC UA for PROFINET Remote IO6.8.1.3 Classic Statusclassic status codes, OPC UA Servers shall set the status information delivered for one Process Value and the OPC UA StatusCode consistent as defined in Table 15 . Table 15 - Classic
-
OPC-30142 – OPC UA for PROFINET Remote IOProcess Value Qualifier and StatusCode Relationship for RIOforFA RIOforFA status information is conveyed to the Client as copy of the original status transmitted in the telegram signal. The value ... encoded into additional qualifier values encoded as RioQualityEnumeration. The status information delivered for one Process Value and the OPC UA StatusCode shall be set consistent as defined in Table
-
OPC-30142 – OPC UA for PROFINET Remote IOmore Process Values in the returned array are "Bad". If no Process Value in the array is "Bad", the Severity returned shall be "Uncertain
-
OPC-30142 – OPC UA for PROFINET Remote IOencoded as RioSubstitutePolicyEnumeration . The PaDigitalSubstituteValue bit field Property contains the substitute values for the Process Value of the represented digital RIOforPA channels which shall be used if a failure ... SubstitutePolicy Property . The FaDigitalSubstituteValue bit field Property contains the substitute values for the Process Value of the represented digital RIOforFA channels which shall be used if a failure is detected
-
OPC-30142 – OPC UA for PROFINET Remote IOtype of each array element is RioPaAnalogValueDataType which has two members: Value contains the Process Value and QualifierValue contains the status information associated with each value. The SimulationValues array ... RioPaAnalogValueDataType structures contains the values and qualifiers used as Process Value for each represented analog channel if simulation is active for the channel. The SimulationEnabled array Variable contains True
-
OPC-30142 – OPC UA for PROFINET Remote IOtype of each array element is RioPaDigitalValueDataType which has two members: Value contains the Process Value and QualifierValue contains the status information associated with each value. The SimulationValues array ... RioPaDigitalValueDataType structures contains the values and qualifiers used as Process Value for each represented digital channel if simulation is active for the channel. The SimulationEnabled array Variable contains True
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.1 RioPaAnalogInputChannelTypeValue MANUAL, the Value of the ManualProcessValue Variable shall be used as Process Value . The ManualProcessValue Variable contains the value used as Process Value if the Mode Variable ... Variable contains True if the Value of the SimulationValue Variable shall be used as Process Value , otherwise False. The SimulationValue Variable contains the value used as Process Value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.6 RioFaAnalogInputChannelTypeReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the RioChannelType . 0:HasComponent Variable ProcessValue RioFaAnalogProcessValueDataType RioFaAnalogProcessValueVariableType M, RO 0:HasComponent Variable SignalValue 0:Double 0:BaseAnalogType ... HasComponent Variable Config RioFaAnalogInputConfigDataType RioFaAnalogInputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the current analog Input value for usage by a Controller . The SignalValue Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.1 RioPaAnalogOutputChannelTypeReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the RioChannelType . 0:HasComponent Variable ProcessValue RioPaAnalogProcessValueDataType RioPaAnalogProcessValueVariableType M, RO 0:HasComponent Variable ProcessValueReadback RioPaAnalogProcessValueDataType RioPaAnalogProcessValueVariableType O, RO 0:HasComponent Variable ... Method SetSimulation O 0:HasComponent Method SetSimulationValue O Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the current analog Output value for an automated process. The ProcessValueReadback Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.6 RioFaAnalogOutputChannelTypeReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the RioChannelType . 0:HasComponent Variable ProcessValue RioFaAnalogProcessValueDataType RioFaAnalogProcessValueVariableType M, RO 0:HasComponent Variable ProcessValueReadback RioFaAnalogProcessValueDataType RioFaAnalogProcessValueVariableType O, RO 0:HasComponent Variable ... HasComponent Variable Config RioFaAnalogOutputConfigDataType RioFaAnalogOutputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the current analog Output value for an automated process. The ProcessValueReadback Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.1 RioPaDigitalInputChannelTypeValue MANUAL, the Value of the ManualProcessValue Variable shall be used as Process Value . The ManualProcessValue Variable contains the value used as Process Value if the Mode Variable ... Variable contains True if the Value of the SimulationValue Variable shall be used as Process Value , otherwise False. The SimulationValue Variable contains the value used as Process Value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.6 RioFaDigitalInputChannelTypeReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the RioChannelType . 0:HasComponent Variable ProcessValue RioFaDigitalProcessValueDataType RioFaDigitalProcessValueVariableType M, RO 0:HasComponent Variable SignalValue 0:Double 0:BaseAnalogType ... HasComponent Variable Config RioFaDigitalInputConfigDataType RioFaDigitalInputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the digital Input value for a Controller . The SignalValue Variable contains the input signal
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.1 RioPaDigitalOutputChannelTypeManualOutValue Variable shall be used as Output value in place of the Process Value . The ManualOutValue Variable contains the value used as Output value to an automated process in place ... Process Value if the Mode Variable of the channel contains the Value MANUAL. The SimulationEnabled Variable contains True if the Value of the SimulationValue Variable shall be used as Process
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.6 RioFaDigitalOutputChannelTypeReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the RioChannelType . 0:HasComponent Variable ProcessValue RioFaDigitalProcessValueDataType RioFaDigitalProcessValueVariableType M, RO 0:HasComponent Variable ProcessValueReadback RioFaDigitalProcessValueDataType RioFaDigitalProcessValueVariableType O, RO 0:HasComponent Variable ... HasComponent Variable Config RioFaDigitalOutputConfigDataType RioFaDigitalOutputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains a Controller's output data to an automated process. The ProcessValueReadback Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaDigitalProcessValueVariableType The RioPaDigitalProcessValueVariableType represents the Process Value of a digital RIO Channel according to RIOforPA. Table 63 - RioPaDigitalProcessValueVariableType Definition Attribute Value BrowseName RioPaDigitalProcessValueVariableType IsAbstract False ValueRank -1 (-1 = Scalar) DataType ... Byte RioPaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value as transmitted in the telegram signal. The Value of the QualifierValue Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaDigitalProcessValueVariableType The RioFaDigitalProcessValueVariableType represents the Process Value of a digital RIO Channel according to RIO FA . Table 64 - RioFaDigitalProcessValueVariableType Definition Attribute Value BrowseName RioFaDigitalProcessValueVariableType IsAbstract False ValueRank -1 (-1 = Scalar ... Boolean RioFaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value bit as transmitted in the telegram signal. The Value of the QualifierValue Variable contains
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaAnalogProcessValueVariableType The RioPaAnalogProcessValueVariableType represents the Process Value of an analog RIO Channel according to RIOforPA. Table 65 - RioPaAnalogProcessValueVariableType Definition Attribute Value BrowseName RioPaAnalogProcessValueVariableType IsAbstract False ValueRank -1 (-1 = Scalar) DataType ... RioPaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process Value as transmitted in the telegram signal. The optional EngineeringUnits Property of the DataValue Variable
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaAnalogProcessValueVariableType The RioFaAnalogProcessValueVariableType represents the Process Value of an analog RIO Channel according to RIO FA . Table 66 - RioFaAnalogProcessValueVariableType Definition Attribute Value BrowseName RioFaAnalogProcessValueVariableType IsAbstract False ValueRank -1 (-1 = Scalar ... RioFaProcessValueQualifierVariableType O, RO Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process Value as transmitted in the telegram signal. The optional EngineeringUnits Property of the DataValue Variable
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaProcessValueQualifierVariableType The RioPaProcessValueQualifierVariableType contains qualifier information for a Process Value of RIO Channels according to RIOforPA. Table 67 - RioPaProcessValueQualifierVariableType Definition Attribute Value BrowseName RioPaProcessValueQualifierVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaProcessValueQualifierVariableType The RioFaProcessValueQualifierVariableType contains qualifier information for a Process Value of RIO Channels according to RIOforFA. Table 68 - RioFaProcessValueQualifierVariableType Definition Attribute Value BrowseName RioFaProcessValueQualifierVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue 0:Boolean Substitute value for the Process Value . Its representation in the AddressSpace is defined in Table 78 . Table 78 - RioPaDigitalInputConfigDataType Definition
-
OPC-30142 – OPC UA for PROFINET Remote IORioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue 0:Boolean Substitute value for the Process Value . Its representation in the AddressSpace is defined in Table 80 . Table 80 - RioFaDigitalInputConfigDataType Definition
-
OPC-30142 – OPC UA for PROFINET Remote IORioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue 0:Boolean Substitute value for the Process Value . SubstituteTime 0:Float Time in seconds from the detection of a failure
-
OPC-30142 – OPC UA for PROFINET Remote IORioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue 0:Boolean Substitute value for the Process Value . SubstituteTime 0:Float Time in seconds from the detection of a failure
-
OPC-30142 – OPC UA for PROFINET Remote IOSubstitutePolicy RioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue RioAnalogDataType Substitute value for the Process Value . HighLimit RioAnalogDataType Upper limit of an analog signal. LowLimit RioAnalogDataType Lower limit
-
OPC-30142 – OPC UA for PROFINET Remote IOSubstitutePolicy RioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue RioAnalogDataType Substitute value for the Process Value . Its representation in the AddressSpace is defined in Table 88 . Table 88 - RioFaAnalogInputConfigDataType Definition
-
OPC-30142 – OPC UA for PROFINET Remote IOSubstitutePolicy RioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue RioAnalogDataType Substitute value for the Process Value . SubstituteTime 0:Float Time in seconds from the detection of a failure
-
OPC-30142 – OPC UA for PROFINET Remote IOSubstitutePolicy RioSubstitutePolicyEnumeration Substitute value setting of the channel. SubstituteValue RioAnalogDataType Substitute value for the Process Value . SubstituteTime 0:Float Time in seconds from the detection of a failure
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.1 RioPaDigitalValueDataTypeRioPaDigitalValueDataType This structure contains the Process Value and the qualifier of a digital RIO Channel according to RIOforPA. Table 93 - RioPaDigitalValueDataType Structure Name Type Description RioPaDigitalValueDataType structure Subtype
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.2 RioFaDigitalValueDataTypeRioFaDigitalValueDataType This structure contains the Process Value and the qualifier of a digital RIO Channel according to RIOforFA. Table 95 - RioFaDigitalValueDataType Structure Name Type Description RioFaDigitalValueDataType structure Subtype
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaDigitalProcessValueDataType This structure contains the Process Value of a digital RIO Channel according to RIOforPA. In addition to value and qualifier, the numeric values of the Quality
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaDigitalProcessValueDataType This structure contains the Process Value of a digital RIO Channel according to RIOforFA. In addition to value and qualifier, the numeric value of the Quality member
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.6 RioPaAnalogValueDataTypeRioPaAnalogValueDataType This structure contains the Process Value and the qualifier of an analog RIO Channel according to RIOforPA. Table 103 - RioPaAnalogValueDataType Structure Name Type Description RioPaAnalogValueDataType structure Subtype
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.7 RioFaAnalogValueDataTypeRioFaAnalogValueDataType This structure contains the Process Value and the qualifier of an analog RIO Channel according to RIOforFA. Table 105 - RioFaAnalogValueDataType Structure Name Type Description RioFaAnalogValueDataType structure Subtype
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaAnalogProcessValueDataType This structure contains the Process Value of an analog RIO Channel according to RIOforPA. In addition to value and qualifier, the numeric values of the Quality
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaAnalogProcessValueDataType This structure contains the Process Value of an analog RIO Channel according to RIOforFA. In addition to value and qualifier, the numeric value of the Quality member
-
OPC-30142 – OPC UA for PROFINET Remote IO10.4.4 RioChannelModeEnumerationValue Description AUTO 0 Do not use the value of the ManualProcessValue variable as Process Value of the RIO Channel . MANUAL 1 Use the value of the ManualProcessValue variable ... Process Value of the RIO Channel . OUT_OF_SERVICE 2 The RIO Channel is out of service. Its representation in the AddressSpace is defined in Table 120 . Table 120 - RioChannelModeEnumeration
-
OPC-30142 – OPC UA for PROFINET Remote IO10.4.5 RioQualityEnumerationRioQualityEnumeration Table 121 - RioQualityEnumeration Items Name Value Description GOOD 0 Input : The Process Value can be used by the Controller . Output : The Signal was generated from the Process Value . UNCERTAIN ... error condition could compromise the Process Value ( Input ) or the Signal ( Output ). BAD 2 Input : The Process Value cannot be used by the Controller . Output : The Signal
-
OPC-30142 – OPC UA for PROFINET Remote IO10.4.7 RioQualifierEnumerationPROCESS_SIMULATION_ACTIVE 41 Same as BAD_PROCESS but with simulate flag set. BAD_FUNCTION_CHECK 60 Local override, value not usable. BAD_FUNCTION_CHECK_SIMULATION_ACTIVE 61 Same ... UNCERTAIN_SUBSTITUTE_SET 72 The configured substitute value (see SubstituteValue ) is used as Process Value . UNCERTAIN_SUBSTITUTE_SET_SIMULATION_ACTIVE 73 Same as UNCERTAIN_SUBSTITUTE_SET but with simulate flag
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: GeneralWorkingUnitMonitoringType defined in OPC 40501-1 Machine Tools 0:HasComponent Object <ProcessValue> 7:ProcessValueType OP 0:HasComponent Object <CyclicProcessValue> CyclicProcessValue Type OP 0:HasComponent Object ... MachineryItemState 4:MachineryItemState_ StateMachineType M Conformance Units MetalForming ProcessWorkingUnitType <ProcessValue> describes the monitoring of a signal from the corresponding working unit. Since there are more than one monitoring