Search
94 result(s) for Identifier
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.2.4 Identifier valueIdentifier value The Identifier value element is used within the context of the first three elements to identify the Node . Its data type and format is defined by the IdType ... Identifier values of IdType String are restricted to 4096 characters and shall not contain Unicode control characters. Unicode control characters are defined by Unicode C0 and Unicode C1 . Identifier values
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.2.2.9 NodeIddefined NodeIds. IdentifierType Enumeration The format and data type of the identifier. The value may be one of the following: NUMERIC - the value is an UInt32; STRING - the value ... value is a ByteString ; Value UInt32 or String or Guid or ByteString The identifier for a node in the address space of an OPC UA Server . The DataEncoding
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.4.2.10 NodeIdstring using the format defined in 5.1.12 . NodeIds in NamespaceIndex 0 use the <identifier> form. All other NodeIds use the <namespace-uri> form. The first abnormal ... decoder shall set the NamespaceIndex to 0, the IdType to String and the Identifier to the JSON string
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.4.2.11 ExpandedNodeIdServerIndex to 0, the NamespaceIndex to 0, the IdType to String and the Identifier to the JSON string. When the ServerIndex is 0, decoders shall replace a NamespaceUri with
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsA.3 Numeric Node IdsEach line in the CSV file has the following fields: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is numeric value for the NodeId . Each SymbolName is unique within the CSV file. The BrowsePath
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsH.3 ExpandedNodeIdDescription IdType The IdentifierType encoded as a JSON number. Allowed values are: 0 - UInt32 Identifier encoded as a JSON number. 1 - A String Identifier encoded as a JSON string ... Guid Identifier encoded as described in 5.4.2.7 . 3 - A ByteString Identifier encoded as described in 5.4.2.8 . This field is omitted for UInt32 identifiers. Id The Identifier . The value
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.4 PubSubConfigurationValueDataTyperelated PubSubConfiguration2DataType Structure. Name String The name of the referenced PubSub configuration element. Identifier BaseDataType The identifier value used for the referenced element in the PubSub NetworkMessages . The value ... PubSubConneciton , WriterGroup or DataSetWriter . The value is null otherwise. If ConfigurationElement references a PubSubConnection , Identifier will contain the value of the PublisherId . If ConfigurationElement references a WriterGroup , Identifier will contain
-
OPC-10000-24 – OPC Unified Architecture - Part 24: Schedulerspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location6.2.1 OverviewTypeDefinition Other Subtype of the BaseObjectType defined in OPC 10000-5. 0:HasProperty Variable Identifier 0:String 0:PropertyType M 0:HasComponent Variable WorldFrame 0:BaseDataType {Any} SpatialLocationType ... SpatialObjectsListType shall be used to add application specific identification. The mandatory Property Identifier shall be used to name the SpatialObjectsList . Annex C.3 describes different scenarios
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial LocationSpatialObjectType instance shall be of a discrete subtype of SpatialLocationType ( 7.2 ) Server RSL SpatialObject Identifier Supports the variable Identifier of SpatialObjectType ( 6.1 ). Server RSL SpatialObject AttachPoints Supports the folder AttachPoints
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Locationspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial LocationExample use of the Identifier Property in a multi-server scenario For the use in multi-server scenarios with different servers it might be needed to identify all related SpatialObjectsLists ... bring them in relationship in a higher levelled SpatialObjectsList. For this the Property Identifier of a SpatialObjectsList can be instantiated as the Property Identifier of a SpatialObject contained
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3specified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.3 Object DiagnosticsTable 8 and described below. Presence identifies if there currently is seen an AutoID Identifier (e.g. a code or a transponder) by the device. If supported by a device ... Logbook. The LastAccess FunctionalGroup shall be provided if values for the last AutoID Identifier access are supported for diagnostic purposes. Its predefined parameters are described in the following list: Parameter
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.10 Variable LastScanTimestampbelongs to the Variable LastScanData and represents the point of time the last AutoID Identifier was scanned. The value of this Variable shall be equal to the SourceTimestamp ... like UtcTime . The use of this Variable implies the following restrictions. Only one AutoID Identifier can be delivered for a scan. The frequency of scans is limited to the sampling
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.4 Method KillTagdisable a transponder. See Annex B for technology specific mappings. Signature KillTag ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] ByteString KillPassword [out] AutoIdOperationStatusEnumeration Status ); Argument Description Identifier AutoID Identifier according ... ScanDataEpc where only the parameter UId is relevant for this Method . If the Identifier is provided from a different source than the ScanResult , a ScanData with a ByteString
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.5 Method LockTagpassword is required. See Annex B for technology specific mappings. Signature LockTag ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] ByteString Password [in] RfidLockRegionEnumeration Region [in] RfidLockOperationEnumeration Lock [in] UInt32 Offset ... UInt32 Length [out] AutoIdOperationStatusEnumeration Status ); Argument Description Identifier AutoID Identifier according to the device configuration as returned as part of a ScanResult in a scan event or scan method
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.6 Method SetTagPasswordwith encryption enabled. See Annex B for technology specific mappings. Signature SetTagPassword ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] RfidPasswordTypeEnumeration PasswordType [in] ByteString AccessPassword [in] ByteString NewPassword [out] AutoIdOperationStatusEnumeration Status ... Argument Description Identifier AutoID Identifier according to the device configuration as returned as part of a ScanResult in a scan event or scan method. The ScanData DataType is defined
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.7 Method ReadTagreads a specified area from a tag memory. One Method invocation reads one AutoID Identifier . The Call Service used to invoke the Method can take a list of Methods . Therefore ... Call Service . See Annex B for technology specific mappings. Signature ReadTag ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] UInt16 Region [in] UInt32 Offset [in] UInt32 Length [in] ByteString Password
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.8 Method WriteTagRFID tag. See Annex B for technology specific mappings. Signature WriteTag ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] UInt16 Region [in] UInt32 Offset [in] ByteString Data [in] ByteString Password ... AutoIdOperationStatusEnumeration Status ); Argument Description Identifier AutoID Identifier according to the device configuration as returned as part of a ScanResult in a scan event or scan method. The ScanData DataType
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.9 Method WriteTagIDAnnex B for technology specific mappings. Signature WriteTagID ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] ByteString NewUId [in] Byte AFI [in] Boolean Toggle [in] ByteString Password [out] AutoIdOperationStatusEnumeration Status ); Argument ... Description Identifier AutoID Identifier according to the device configuration as returned as part of a ScanResult in a scan event or scan method. The ScanData DataType is defined
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.11 Variable LastScanAntennaVariable LastScanData and represents the ID of the antenna with which the last AutoID Identifier was scanned. The Variable can be provided for simple applications where OPC UA Clients ... like UtcTime . The use of this Variable implies the following restrictions. Only one AutoID Identifier can be delivered for a scan. The frequency of scans is limited to the sampling
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.12 Variable LastScanRSSIVariable LastScanData and represents the RSSI Value with which the last AutoID Identifier was scanned. The Variable can be provided for simple applications where OPC UA Clients are limited ... like UtcTime . The use of this Variable implies the following restrictions. Only one AutoID Identifier can be delivered for a scan. The frequency of scans is limited to the sampling
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.6.3.2 Method GetLocationwill be apparent from the timestamp returned in the result). Signature GetLocation ( [in] ScanData Identifier [in] CodeTypeDataType CodeType [in] LocationTypeEnum LocationType [out] RtlsLocationResult Result ); Argument Description Identifier AutoID Identifier according ... ScanDataEpc where only the parameter UId is relevant for this Method . If the Identifier is provided from a different source than the ScanResult , a ScanData with a ByteString
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices9.3.17 AccessResultAccessResult This DataType is a structure that defines the result values of an AutoID Identifier access of an AutoID device. Its composition is formally defined in Table 73 . Table ... Subtype of Structure defined in OPC 10000-5 . CodeType CodeTypeDataType Defines the format of Identifier as string. The String DataType CodeTypeDataType and the predefined format strings are defined
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devicesspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackMLspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is numeric value for the NodeId . The BrowsePath for an instance Node is constructed by appending
-
OPC-30060 – OPC UA for Tobacco Machine Communicationspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>specified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30100 – OPC UA for SERCOS Devices4.3.2.1 NodeIdsunique. In this "OPC UA for Sercos Devices companion specification", the Identifier for each Node starts with one out of the three possible connection / addressing types Topological (defined
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecturespecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecturespecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30140 – OPC UA for PROFINETspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30141 – OPC UA for PROFIenergyspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30142 – OPC UA for PROFINET Remote IOspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30200 – OPC UA for Commercial Kitchen Equipmentspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30250 – OPC Unified Architecture for DEXPIspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCSspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-30270 – OPC UA for Asset Administration Shell (AAS)specified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> The SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node, that appears in the specification, and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40077 – OPC UA interfaces for plastics and rubber machinery - Data exchange between injection moulding machines and MESspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devicesspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitionsspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type Definitionsspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion Linespecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-3 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 3: Extruderspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-4 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 4: Haul-offspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-5 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 5: Melt pumpspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-6 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 6: Filterspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-7 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 7: Diespecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-8 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 8: Pelletizerspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-9 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 9: Cutterspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-10 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 10: Calibratorspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-11 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 11: Corrugatorspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40084-12 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 12: Calenderspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40210 – OPC UA for Geometric Measurement Systems8.13 CorrectionTypeTypeDefinition Other Subtype of the BaseObjectType defined in OPC 10000-3 0:HasProperty Variable Identifier 0:String 0:PropertyType 0:Mandatory 0:HasProperty Variable CharacteristicIdentifier 0:String 0:PropertyType ... HasProperty Variable ProgramName 0:String 0:PropertyType 0:Optional Conformance Units GMS CorrectionType Identifier is a unique ID to identify this correction value. CharacteristicIdentifier is a reference to the characteristic
-
OPC-40210 – OPC UA for Geometric Measurement Systems10.3 AdditionalSensorTypeOther Subtype of the 0:AnalogUnitType defined in OPC 10000-3 0:HasProperty Variable Identifier 0:String 0:PropertyType 0:Mandatory 0:HasComponent Variable Class 0:UInteger 0:MultiStateDiscreteType ... HasProperty Variable Name 0:String 0:PropertyType 0:Optional Conformance Units GMS GMSEquipmentType Identifier is the identifier of the sensor. The Identifier shall be unique within the AddressSpace . Class indicates
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpsspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementHasProperty Variable 2:SoftwareRevision 0:String 0:PropertyType M, RO 0:HasProperty Variable Identifier 0:String 0:PropertyType M, RO 0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType ... PLL01 1.10.0.3", "V05.01.01.15", "3.1 R1293", "70.0.1". The Identifier Property provides an identifier to distinguish the software component. 2:Manufacturer refers to the manufacturer/producer
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.4.2 ProductionJobListTypeOrderedObject >, it is recommended to use the value of the Identifier Property of the respective ProductionJobType instance. The 0:NodeVersion and the 0:GeneralModelChangeEventType inherited from the 0:OrderedListType
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.4.3 ProductionJobTypeNode 0:HasProperty Variable CustomerOrderIdentifier 0:String 0:PropertyType O, RO 0:HasProperty Variable Identifier 0:String 0:PropertyType M, RO 0:HasProperty Variable OrderIdentifier 0:String 0:PropertyType ... OrderedObject> ProductionProgramType MP RunsPlanned 0:HasProperty Variable IsValid Boolean PropertyType M, RO The Identifier is the identifier of the job. This Identifier is used to reference
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementProductionJobType instance this program is used in. JobIdentifier holds the same content as the Identifier Property of the ProductionJobType instance this program is used in. State is inherited from
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.4.7 ProductionPartTypeHasProperty Variable Name 0:String 0:PropertyType M, RO 0:HasProperty Variable Identifier 0:String 0:PropertyType O, RO 0:HasComponent Variable PartQuality PartQuality 0:BaseDataVariableType M, RO 0:HasComponent ... This information often originates from an external system handling production organisation (e.g., MES). The Identifier is used to distinguish and identify an individual part in production in a machine
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.5.3 BaseToolTypeinheriting the InstanceDeclarations of that Node. 0:HasProperty Variable Identifier 0:String 0:PropertyType O, RO 0:HasComponent Object Location 0:BaseObjectType O 0:HasProperty Variable Name 0:String ... PropertyType M, RO Location 0:HasProperty Variable PlaceNumber 0:UInt16 0:PropertyType M, RO Identifier is a unique identifier for a tool. The Identifier can be used to provide
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.5.4 ToolTypeprogram or globally, independent of the machine management view, the properties Name and Identifier are provided by the BaseToolType . LastUsage is the time, where the specific tool was the active
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.6.7 PartLoadPrognosisTypeavailable. Otherwhise, if the ProductionType is used instead, it shall be identical to the Identifier property of the ProductionPartType instance the prognosis relates to. PartName shall be identical
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.6.8 PartUnloadPrognosisTypeavailable. Otherwhise, if the ProductionType is used instead, it shall be identical to the Identifier property of the ProductionPartType instance the prognosis relates to. PartName shall be identical
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementOtherwise, if the ProductionType is used, it shall be identical to the Identifier property belonging to the ProductionJobType the prognosis refers to if modelled in the AddressSpace . Otherwise, it shall ... contain the identifier of the job. [DEPRECATED in version 1.02] The JobNodeId shall reference the 0:NodeId of the ProductionJobType instance the prognosis refers to. The JobNodeId component will
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.6.11 ToolChangePrognosisTypetool magazine or the workspace of the machine. ToolIdentifier is identical to the Identifier property of the tool to change, if applicable. If the tool is not modelled
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.6.12 ToolLoadPrognosisTypetool magazine or the workspace of the machine. ToolIdentifier contains the unique identifier of the tool. This value shall be the same as for the Identifier Property of the BaseToolType
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.6.13 ToolUnloadPrognosisTypetool magazine or the workspace of the machine. ToolIdentifier contains the unique identifier of the tool. This value shall be the same as for the Identifier Property of the BaseToolType
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Managementwhich means it inherits the InstanceDeclarations of that Node. 0:HasProperty Variable Identifier 0:String 0:PropertyType M, RO Conformance Units MachineTool Notification - Errors and Alerts Identifier is used
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementHasProperty Variable Name 0:String 0:PropertyType M, RO 0:HasProperty Variable Identifier 0:String 0:PropertyType O, RO 0:HasComponent Variable PartQuality PartQuality 0:BaseDataVariableType M, RO 0:HasComponent ... v102 0:BaseObjectType Conformance Units MachineTool Production ProductionPartStateMachineType JobIdentifier is a copy of the Identifier property of the ProductionJobType instance this part belongs to. All other Properties and Components
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Managementtransition. Name is used as defined in 8.4.4 . JobIdentifier is a copy of the Identifier property of the ProductionJobType instance this program belongs
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information Modelspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40540 – OPC UA for Additive Manufacturinginheriting the InstanceDeclarations of that Node 0:HasProperty Variable Identifier 0:String 0:PropertyType M 0:HasProperty Variable ExternalIdentifier 0:String 0:PropertyType O 0:HasProperty Variable Name 0:String ... Cycle 0:UInt32 0:BaseDataVariableType O Conformance Units AdditiveManufacturing Identify & Monitor Feedstock The Identifier is the Identifier of the feedstock. This Identifier is used to determine the type
-
OPC-40561-1 – OPC UA for Mining - Part 1: Extraction Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40561-2 – OPC UA for Mining - Extraction - Part 2: Shearer Loaderspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40562-1 – OPC UA for Mining - Loading - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40562-2 – OPC UA for Mining - Loading - Part 2: Hydraulic Excavatorspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40563-1 – OPC UA for Mining - Transport Dumping - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40563-2 – OPC UA for Mining - Transport Dumping - Part 2: Armoured Face Conveyorspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40563-3 – OPC UA for Mining - Transport Dumping - Part 3: Rear Dump Truckspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40564-1 – OPC UA for Mining - Mineral Processing - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40564-2 – OPC UA for Mining - Mineral Processing - Part 2: Rock Crusherspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40565-1 – OPC UA for Mining - Development Support - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40565-2 – OPC UA for Mining - Development Support - Part 2: Roof Support Systemspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40565-3 – OPC UA for Mining - Development - Part 3: Dozerspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40566-1 – OPC UA for Mining - Monitoring Supervision Services - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40567-1 – OPC UA for Mining - PELO Services - Part 1: Generalspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40567-2 – OPC UA for Mining - PELO Services - Part 2: Face Alignment Systemspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending
-
OPC-40600 – OPC UA for Weihenstephan Standardsspecified in a CSV file with the following syntax: <SymbolName>, <Identifier>, <NodeClass> Where the SymbolName is either the BrowseName of a Type Node ... BrowsePath for an Instance Node that appears in the specification and the Identifier is the numeric value for the NodeId . The BrowsePath for an Instance Node is constructed by appending