Search
99 result(s) for Description
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Modelrepresents the information model version where the Node was first deprecated . The DisplayName and Description of the TargetNode should suggest the information model version and other suggestions
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.1.1 Overviewthat will be contained in the Event such as EventId , EventType , SourceNode , Time and Description . OPC 10000-3 describes the Event model and the base EventTypes . The Properties
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model5.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelBaseObjectType defined in 6.2 . Conformance Units Historical Access Aggregates For the AggregateFunctionType , the Description Attribute is mandatory. The Description Attribute provides a localized description of the AggregateFunction. Specific AggregateFunctions
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessProperties . Other Attributes that are defined for Variable s in OPC 10000-3 (e.g., Description ) can also be available
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Accessreturn the invariant locale. The Name field shall be used as invariant locale for description . Servers can configure multiple additional locales for each description . However, if none of the LocaleIds
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Accessinvariant locale. The Preferred Name field shall be used as invariant locale for description . Servers can configure multiple additional locales for each description . However, if none of the LocaleIds specified
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Accessbattery capacity" or "pressure in relation to volume flow rate". The Description Attribute should be used to expose a more verbose explanation of the QuantityType instance
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access6.4.2.2 UnitType ObjectType Definitiondegree Celsius" or "square metre". This matches the "description" field of the EUInformation structure (see 5.6.4.3 ). The Description Attribute should be used to expose
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.3 ItemA.3.1.5 . TimeZone property in the DA server is represented by a TimeZone Property. The Description property value in the DA server is assigned to the Description Attribute . The DataType property
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.4.2.2 Object Nodesnode in the OPC UA Server is assigned to this property. UA Description (Property ID: 614): The value of the Description attribute of the node in the OPC UA Server ... assigned to this property, if a Description attribute is provided. Item Description (Property ID: 101): The value of the DisplayName attribute of the node in the OPC UA Server
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.4.2.3 Variable Nodesvalue of the EngineeringUnits property node is assigned the EU Units property . Item Description (Property ID: 101): The value of the DisplayName attribute of the node ... node in the OPC UA Server is assigned to this property. UA Description (Property ID: 614): The value of the Description attribute of the node in the OPC UA Server
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates4.2.2.2 AggregateFunctionTypedefined in OPC 10000-5 Conformance Units Historical Access Aggregates For the AggregateFunctionType , the Description Attribute (inherited from the Base NodeClass ) , is mandatory. The Description Attribute provides a localized description ... Aggregate . Table 5 specifies the BrowseName and Description Attributes for the standard Aggregate Objects . The description is the localized "en" text. For other locales it shall be translated
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.12.2 Supported configuration propertiesKeyValuePair. Value of the Variable provides the default value for the property. Description of the Variable provides additional information. Properties like EURange or EngineeringUnits can be used to provide value
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringfile may not be present in the Server due to memory reasons. Description X If not present in the AML, the OPC UA Description is inferred by the Description ... attribute in the Header of the AML object. If the OPC UA Description is present and has multiple localizations, the localizations are mapped to additional localized sub-attributes
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute can be set to writable since a Server can provide a server-specific description
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.5.3 AddLink Methoduser can change the URI. In addition, the BrowseName , DisplayName , and Description might be writable. Servers might restrict the execution of this Method as well as writing the Attributes ... UriString LinkToExternalSource, [in] 0:QualifiedName BrowseName, [in] 0:LocalizedText DisplayName, [in] 0:LocalizedText Description, [out] 0:NodeId LinkVariable); Table 31 - AddLink Method Arguments Argument Description LinkToExternalSource Link to an external
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping3.3.3.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation5.2.9 AcousticSignalTypedefined in Table 28 . Table 28 - AcousticSignalType Definition Attribute Value BrowseName AcousticSignalType IsAbstract False Description Represents an acoustic signal. References Node Class BrowseName DataType TypeDefinition Other Subtype ... UInteger 0:PropertyType M 0:HasComponent Variable AudioSample 0:AudioDataType 0:BaseDataVariableType O The Description Attribute of each Object of type AcousticSignalType should be used as textual description
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning3.4.3.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job Control3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition3.4.2.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-33.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3defined in Table 26 . Table 26 - Common Node Attributes Attribute Use DataType Description NodeId Mandatory NodeId The NodeId is a unique identifier for a Node in an OPC UA Address ... Variable name and an empty LocaleId string if the server does not support localization. Description Optional LocalizedText The optional Description shall describe the meaning of the Node using a localized
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is vendor specific. Description Optionally a vendor specific description is provided NodeClass Shall reflect the NodeClass of the Node NodeId ... Attributes to not writeable that are not said to be vendor-specific like Description, EventNotifier or DisplayName with a LocaleId other than 'en'. For example, the Description Attribute
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model3.5.3.1 GeneralWhether the server provides translated names for other LocaleIds is vendor specific. Description Optionally a vendor specific description is provided NodeClass Shall reflect the NodeClass of the Node NodeId ... writeable that are not said to be vendor-specific. For example, the Description Attribute may be set to writeable since a Server may provide a server-specific description
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelTypeDefinition of the OPC UA Object instance. The BACnet properties Object_Name, Description and Update_Interval are mapped to the OPC UA Attributes BrowseName , Description and MinSamplingInterval . The BACnet properties
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model5.2 Model OverviewObject Object_Type is mapped to the type definition of the OPC UA Object Description is mapped to the OPC UA Attribute Description of the OPC UA Object Present_Value
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelObject Object_Type is mapped to the type definition of the OPC UA Object Description is mapped to the OPC UA Attribute Description of the OPC UA Object
-
OPC-30040 – OPC UA for AutomationML - Xxx: OPC UA Information Model for AutomationML3.3.4.1 GeneralWhether the server provides translated names for other LocaleIds is vendor specific. Description Optionally a vendor specific description is provided NodeClass Shall reflect the NodeClass of the Node NodeId ... writeable that are not said to be vendor-specific. For example, the Description Attribute may be set to writeable since a Server may provide a server-specific description
-
OPC-30060 – OPC UA for Tobacco Machine Communication3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™3.4.3.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>3.3.5.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is vendor specific. Description Optionally a vendor specific description is provided NodeClass Shall reflect the NodeClass of the Node NodeId ... writeable that are not said to be vendor-specific. For example, the Description Attribute may be set to writeable since a Server may provide a server-specific description
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified ArchitectureHasProperty Variable ProductId String PropertyType Mandatory HasProperty Variable Name LocalizedText PropertyType Mandatory HasProperty Variable Description LocalizedText PropertyType Mandatory HasComponent Variable DeviceSymbol Image BaseDataVariableType Optional HasComponent Variable DeviceIcon Image BaseDataVariableType Optional ... DeviceVariant/ProductName element shall be used. Localization should be considered. The mandatory, read-only Property Description maps to the IODD DeviceVariant/ Description. Localization should be considered. For IODDs following the IODD
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture12.3.2 Structure DataTypedefault language English resolved textId) shall map to the field name of StructureField The Description of the IODD RecordItem shall map to the field description of StructureField The data type
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.6.2 CSPP elementProperties of the DataVariable s. Table 7‑2 shows the mapping specifications. Instead of description omission in the COMM_IF_VARIABLE part and COMM_IF_CONFIGURATION part, the mapping specifications ... using this item value to the Value Attribute value of the DataVariable . 13. COMMENT Description Attribute Maps the item value to the Attribute value. *1: For the COMM_IF_CONFIGURATION
-
OPC-30140 – OPC UA for PROFINET3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30141 – OPC UA for PROFIenergy3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30142 – OPC UA for PROFINET Remote IO3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.5.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model3.4.3.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives3.5.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30200 – OPC UA for Commercial Kitchen Equipment3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30250 – OPC Unified Architecture for DEXPI4.2.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30270 – OPC UA for Asset Administration Shell (AAS)3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics3.4.3.1 Generalspecification. Whether the Server provides translated names for other LocaleIds is server specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writeable. For example, the Description Attribute may be set to writeable since a Server may provide a server-specific description
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsHasProperty Variable ApplicationUri 0:String 0:PropertyType M 0:HasProperty Variable Description 0:LocalizedText 0:PropertyType M 0:HasProperty Variable DeviceProgramRunId 0:String 0:PropertyType O 0:HasProperty Variable EstimatedRuntime ... access Token Claim should be utilized (refer to 10000-6 section 6.5.3.2). Description is the human-readable description of the specific program run that created this result and the result
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsPropertyType M 0:HasProperty Variable Created DateTime 0:PropertyType M 0:HasProperty Variable Description LocalizedText 0:PropertyType M 0:HasProperty Variable Modified DateTime 0:PropertyType M 0:HasProperty Variable DeviceTemplateId ... user who created the template. Created is the time of the template's creation. Description is a human-readable description of the template. Modified is the time of last modification
-
OPC-34100 – OPC UA for Energy Consumption Management3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-34100 – OPC UA for Energy Consumption Management6.2.2.1 Overviewdocument (see Annex A ). Table 15 - Format of Definition of standardized Measurements MeasurementID BrowseName Description EngineeringUnits MeasurementPeriod DataType HasStatisticComponent The MeasurementID is a unique numeric identification. The BrowseName (leaving ... EnergyMeasurementType . Those BrowseNames are also used for the interfaces (see 6.2.3 ). The Description (in English) may be used as the Description Attribute for those Nodes . For all instances of EnergyMeasurementType
-
OPC-34100 – OPC UA for Energy Consumption Managementmeasured import and export parts (sum = import - export) Some explanations to the Description text in the table: Qtot is according to IEC61557-12 [4] the reactive power calculated
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building BlocksTable 29 . Table 29 - MachineryItemState_StateMachineType Definition Attribute Value BrowseName MachineryItemState_StateMachineType IsAbstract False Description State machine representing the state of a machinery item References Node Class BrowseName DataType TypeDefinition ... executing a maintenance process. The meaning of the Transitions is defined in the Description of Table 30 . The InstanceDeclarations of the MachineryItemState_StateMachineType have additional Attribute values defined in Table
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocksdefined in Table 32 . Table 32 - MachineryOperationModeStateMachineType Definition Attribute Value BrowseName MachineryOperationModeStateMachineType IsAbstract False Description State machine representing the operation mode of a MachineryItem References Node Class BrowseName DataType TypeDefinition ... value adding activities. The meaning of the Transitions is defined in the Description of Table 33 . The InstanceDeclarations of the MachineryOperationModeStateMachineType have additional Attribute values defined in Table 33 . Table
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks17.1 Overviewused. The IMachineryEquipmentType is derived from the IMachineTagNameplateType and adds the MachineryEquipmentTypeId and Description . Figure 27 - MachineryEquipmentFolderType and IMachineryEquipmentType Figure 28 shows an example where the MachineryEquipment is directly
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions3.2.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40084-3 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 3: Extruder7.7.2 DescriptionDescription The Description Property gives a description of the feeder/dosing unit
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoring3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40210 – OPC UA for Geometric Measurement Systems4.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40210 – OPC UA for Geometric Measurement Systems8.13 CorrectionTypeOptional 0:HasComponent Variable LowerControlLimit 0:Double 0:AnalogUnitType 0:Optional 0:HasProperty Variable Description 0:LocalizedText 0:PropertyType 0:Optional 0:HasProperty Variable ProgramName 0:String 0:PropertyType ... LowerControlLimit is the lower limit from which on a correction should be applied. Description is a human-readable description of the correction of the correction value. ProgramName contains the name
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40301 – OPC UA for Flat Glass Processing3.5.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40444 – OPC UA for Textile Testing Devices3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Base3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: BasePropertyType M 0:HasProperty Variable IntegratorName 0:String 0:PropertyType O 0:HasProperty Variable Description 0:LocalizedText 0:PropertyType O 0:HasProperty Variable JoiningTechnology 0:LocalizedText 0:PropertyType ... Table 21 . Table 21 - JoiningSystemIdentificationType Attribute values for child nodes BrowsePath Value Attribute Description Attribute 0:DefaultInstanceBrowseName 2:Identification The default BrowseName for instances of the type. 2: ProductInstanceUri
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: BaseDataType TypeDefinition Others 2:Identification 0:HasInterface ObjectType IJoiningAdditionalInformationType 2:Identification 0:HasProperty Variable Description 0:LocalizedText 0:PropertyType O, RO 2:Identification 0:HasProperty Variable JoiningTechnology 0:LocalizedText ... MachineIdentificationType or MachineryComponentIdentificationType. The 2:Identification Object implements IJoiningAdditionalInformationType interface with the following properties: Description is the system specific description of the asset. Note: Although there is a description attribute
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information Model3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds is vendor specific. Description Optionally a vendor specific description is provided NodeClass Shall reflect the NodeClass of the Node NodeId ... writeable that are not said to be vendor-specific. For example, the Description Attribute may be set to writeable since a Server may provide a server-specific description
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: General3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40504-1 – OPC UA for Cutting Tools - Part 1: Manufacturing3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40530 – OPC UA for Laser Systems3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40530 – OPC UA for Laser Systemsinheriting the InstanceDeclarations of that Node. 0:HasComponent Variable Description 0:LocalizedText 0:BaseDataVariableType M, RO 0:HasProperty Variable Code 0:String 0:PropertyType O, RO Conformance Units LaserSystems LaserSystemMaintenancePrognosisType ... service A" or "Check up of the main coolant loop". The Description indicates in a more elaborate (as compared to 4:UtilityName) and textual form what
-
OPC-40530 – OPC UA for Laser Systemsinheriting the InstanceDeclarations of that Node. 0:HasComponent Variable Description 0:LocalizedText 0:BaseDataVariableType M, RO 0:HasProperty Variable Code 0:String 0:PropertyType O, RO Conformance Units LaserSystems LaserSystemUtilityChangePrognosisType ... exchanged. Examples may be "Air filter" or "Coolant water". The Description indicates in a more elaborate (as compared to 4:UtilityName) and textual form what
-
OPC-40540 – OPC UA for Additive Manufacturing3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40560 – OPC UA for Mining - General3.2.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40570 – OPC UA for Wire Harness Manufacturing3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40600 – OPC UA for Weihenstephan Standards3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40700 – OPC UA for Surface Technology - General Types3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40700 – OPC UA for Surface Technology - General TypesMonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent Object Description 0:FolderType O Identification is used as defined in OPC 40001-1. It represents numerous identification ... Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in. Description is representing a collection of ObjectTypes and VariableTypes that describe the overall system. This
-
OPC-40700 – OPC UA for Surface Technology - General TypesMonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent Object Description 0:FolderType O Identification is used as defined in OPC 40001-1. It represents numerous identification ... Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in. Description is representing a collection of ObjectTypes and VariableTypes that describe the component. This
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply Systems3.3.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsMonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STSysMaterialTransportLineType Basic MSS STSysMaterialTransportLineType Monitoring MSS STSysMaterialTransportLineType Description Monitoring ... Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in. Description represents a collection of ObjectTypes and VariableTypes that describe the material transport line. This
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsMonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STCompRamType Basic MSS STCompRamType Monitoring MSS STCompRamType Description Monitoring ... Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in. Description represents a collection of ObjectTypes and VariableTypes that describe the ram. This may be information
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsOther Subtype of the 5:STCompType defined in OPC 40700 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STCompPowderSieveType Basic MSS STCompPowderSieveType Description Description represents a collection ... Table 28 - STCompPowderSieveType Additional Subcomponents Source Path Reference NodeClass BrowseName DataType TypeDefinition Others 5:Description 0:HasComponent Variable PowderSieveMeshSize 0:Double 0:AnalogUnitType O PowderSieveMeshSize represents the mesh size
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsMonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STCompProcessValveType Basic MSS STCompProcessValveType Monitoring MSS STCompProcessValveType Description Monitoring ... Machinery (OPC 40001-1, OPC 40001-3) which are implemented as an add-in. Description represents a collection of ObjectTypes and VariableTypes that describe the valve. This may be information
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsMonitoringType O 0:HasAddIn Object 4:Components 4:MachineComponentsType O 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STSysVesselType Basic MSS STSysVesselType Monitoring MSS STSysVesselType Components ... STSysVesselType Description Monitoring represents a collection of ObjectTypes and VariableTypes , representing the current state of the process that are assigned to the component. Components represents a collection of ObjectTypes that
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsHasComponent Object 4:Monitoring 4:MonitoringType O 0:HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STCompHeaterType Basic MSS STCompHeaterType Monitoring MSS STCompHeaterType Description Monitoring represents a collection ... VariableTypes , representing the current state of the process that are assigned to the component. Description represents a collection of ObjectTypes and VariableTypes that describe the heater. This may be information
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting Machinery3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40719 – OPC UA for Plasma Surface Technology3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)3.4.3.1 GeneralWhether the server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass of the Node. NodeId ... shall set all non-server-specific Attributes to not writable. For example, the Description Attribute may be set to writable since a Server may provide a server-specific description