Search
65 result(s) for ConformanceUnit
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles3.1.3 ConformanceUnitConformanceUnit a specific set of OPC UA features that can be tested as a single entity Note 1 to entry: A ConformanceUnit can cover a group of services, portions
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Modelkeyword column contains the actual Profiles/Facets that apply. For more detail on the ConformanceUnit or Profile , please use the on-line Profile Application available at OPC Profiles . The mapping only
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Modelthat require the Node to be in the AddressSpace . If a Server supports a ConformanceUnit , it shall expose the Nodes related to the ConformanceUnit in its AddressSpace . If two Nodes ... ConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnit is reflected with a Category element in the UANodeSet file
-
OPC-10000-7 – OPC Unified Architecture - Part 7: ProfilesConformance Units and Conformance Groups Each ConformanceUnit represents a specific set of features (e.g. a group of services, portions of services or information models) that can be tested ... single entity. ConformanceUnits are the building blocks of a Profile . Each ConformanceUnit can also be used as a test category. For each ConformanceUnit, there would be a number of TestCases
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles4.3 ProfilesProfiles will be added in the future. Multiple Profiles may include the same ConformanceUnit . Testing of a Profile consists of testing the individual ConformanceUnits that comprise the Profile . Profiles
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profilesoptional ConformanceUnits . Optional means that an application has the option to not support the ConformanceUnit . However, if supported, the application shall pass all tests associated with the ConformanceUnit ... application desires to be listed as supporting the optional ConformanceUnit then it shall include any required information model items in the configuration provided for certification testing. The test result that
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model5.1 Overviewpersist LogRecords (i.e. LogRecords will be retained following a restart) is defined in a ConformanceUnit and may be added to a Profile . The LogObject exposes a Method that allows
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConformanceUnits and Node definitions Each Node defined in this document references at least one ConformanceUnit. (defined in OPC 10000-84 ). If a Server supports the ConformanceUnit , it shall expose ... Nodes related to the ConformanceUnit in its AddressSpace . If two Nodes are exposed, all References between the Nodes defined in this document shall be exposed as well. The relations between
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.1 OverviewOverview A ConformanceUnit , defined in OPC 10000‑7 , represents an individually testable entity. For improved clarity, the list of ConformanceUnits is arranged into named ConformanceGroups . Table 2 lists the ConformanceGroups ... Networking Quantities Define concrete values or value ranges related to UAFX Ethernet networking features ConformanceUnit s. UAFX SKS Defines ConformanceUnits for UAFX SKS implementations
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponentleast one of the UAFX AutomationComponent AcDescriptor DescriptorFile or UAFX AutomationComponent AcDescriptor DescriptorIdentifier ConformanceUnit , where at least one Descriptor complies with the UAFX Offline Descriptor Profile. Server UAFX AutomationComponent AcDescriptor
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profileslower application cycle times can be achieved with reduction and sub-cycling (see ConformanceUnit UAFX EthernetBridgeQuantities Scheduled Traffic GCL 16/64
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesOffline UAFX Descriptor AcDescriptor DescriptorIdentifier If the product supports the UAFX AutomationComponent AcDescriptor DescriptorIdentifier ConformanceUnit , the AML descriptions of all instances of AutomationComponentType AcDescriptorType DescriptorIdentifier and DescriptorVersion Variables and their ... included. Offline UAFX Descriptor AutomationComponent Base If the product supports the UAFX AutomationComponent Base ConformanceUnit , the AML descriptions of all instances of AutomationComponentType are included. Offline UAFX Descriptor AutomationComponent PublisherCapabilities
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesUAFX Descriptor Network Priority Mapping If the product supports the UAFX EthernetUAFXStation Default PriorityMappingTable ConformanceUnit , the AML description of the UAFX Information Model Objects required by that ConformanceUnit and their ... UAFX Descriptor Network Physical Interfaces If the product supports the UAFX EthernetUAFXStation Physical Interface ConformanceUnit , the AML description of the UAFX Information Model Objects required by that ConformanceUnit and their
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.2 Profile listConformanceUnits are referenced using their name and conformance group. For the details of the ConformanceUnit, the reader should examine the ConformanceUnit details in clause
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.1 Overviewcontains three columns. The first column is a description of the ConformanceGroup that the ConformanceUnit is part of (see 5.1 ). This allows the reader to easily find the ConformanceUnit . This ... column may also be empty, in which case the listed item is not a ConformanceUnit , but an included Profile or Facet. The second column is a brief description
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.3.6 IA-station Facetadds the option to include Bridge Component Facets (via the UAFX EthernetIAStation ContainsBridge ConformanceUnit ). It also adds functionality for Topology Discovery , Remote Management and Time Synchronization . Table 39 - IA-station
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profileschanging Input to Controller, and removed "for input data" from the ConformanceUnit Description. 9481 Clarification UAFX ConnectionManager Base ConfomanceUnit language should be improved Updated the ConformanceUnit description ... ConnectionManager AutomationComponentConfiguration AssetVerification CU should be made mandatory Made the UAFX ConnectionManager AutomationComponentConfiguration AssetVerification ConformanceUnit mandatory and updated the UAFX ConnectionManager Facet to a new 2024 Facet. 9483 Errata UAFX
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.3.1.1 Node definitionsthat require the Node to be in the AddressSpace . If a Server supports a ConformanceUnit , it shall expose the Nodes related to the ConformanceUnit in its AddressSpace . If two Nodes ... ConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnit is reflected with a Category element in the UANodeSet file
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicsglobally unique identification of an asset, the 2: ProductInstanceUri shall be provided (see ConformanceUnit AMB Asset Identification in 15.1 ). It shall be either a Property of the Object representing ... provided it shall be writable to allow a configurable identification of the asset (see ConformanceUnit AMB Configurable Asset Identification in 15.1 ). Other Properties of 2: ITagNameplateType and additional configurable Properties
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management BasicsServerCapabilites Object , like the supported OPC UA Profiles in the ServerProfileArray . The corresponding ConformanceUnit is already defined in OPC 10000-7 . Therefore, this specification does not further address this topic
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping3.3.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial LocationCylindricalCoordinatesFrameType or the PolarCoordinatesFrameType ). Figure 25 - Examples of subtypes of SpatialLocationType By describing a ConformanceUnit (similar to the CartesianFrameAngleOrientationType ConformanceUnit ) for a created subtype of SpatialLocationType and combining this with
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job ControlProfiles and Conformance Units Profiles and ConformanceUnits break functionality into testable groups. A ConformanceUnit describes a testable unit. A single ConformanceUnit is tested as a unit so all items covered ... must be supported or the ConformanceUnit will fail. ConformanceUnits can be included in multiple Profiles, so they are declared in their own table
-
OPC-30020 – MDIS OPC UA Companion Specification4.1 MDIS definitionsAddressSpace permitted to have data values. See OPC 10000-3 for additional details. ConformanceUnit As defined by the OPC Foundation: a specific set of OPC UA features that ... tested as a single entity. As it applies to MDIS a ConformanceUnit may describe a specific Object or part of a specific Object . It may also describe general functionality such
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerLlimit , LLlimit . The actual list of supported limits is reported as part of the ConformanceUnit . Server MDIS Instrument Setpoints Supports at least one of the following set points: HHSetPoint , HSetPoint ... LSetPoint , LLSetPoint . The actual list of supported setpoints is reported as part of the ConformanceUnit . Instrument Out Server MDIS Instrument Out Base Supports the base required aspect of the MDISInstrumentOutObjectType
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex, that is containing components by themselves
-
OPC-30142 – OPC UA for PROFINET Remote IO12.2.2.3 PNRIO Base Server ProfilePNRIO Conformance Units , the PNRIO Base Server Profile demands the PNRIO Channel Objects Conformance Unit only. Servers implementing this Profile provide Channel Objects , but do not offer Channel Group Objects ... Process Variables or a RioChannelGroupConfigType Object . Table 138 - PNRIO Base Server Profile Group Conformance Unit / Profile Title Mandatory / Optional PNRIO PNRIO Common Server Facet M PNRIO PNRIO Channel Objects
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.5.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model11.2.2.3 PNGSDGM Advanced Server ProfileAdvanced Server Profile Table 53 defines a Profile that adds the Generic Data Objects Conformance Unit to the minimum OPC UA functionality defined by the PNGSDGM Base Server Profile . Table ... PNGSDGM Advanced Server Profile Group Conformance Unit / Profile Title Mandatory / Optional Profile 0:Core 2017 Server Facet http://opcfoundation.org/UA-Profile/Server/Core2017Facet M Profile 0:UA-TCP UA-SC UA Binary
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives3.5.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics3.4.1.1 Node definitionsdefined at the end of the tables defining the Nodes , with one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex; that is, containing components themselves
-
OPC-34100 – OPC UA for Energy Consumption Management3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks3.4.1.1 Node DefinitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit, one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.11.1 Overviewinside the Server's AddressSpace located within the Conditions folder as defined in the ConformanceUnit RobAckCondInstance . By handling such conditions using the OPC UA Eventing mechanisms as defined ... ConformanceUnit RobAckCondEventing. Figure 21 - SystemOperationType Overview
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integrationprogram the Ready State can be extended by the ReadySubstateMachineType. The Task Control Monitor ConformanceUnit supports monitoring of the activities done by the operator or system internally. The Task Control ... Operation ConformanceUnit supports additional operations by Methods . The overview of the state machine with all transitions is shown in When the state machine changes from Executing State to Ready State
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems13.1 Conformance UnitsConformance Units This chapter defines the corresponding Conformance Unit for OPC 40082-3. Table 27 - Conformance Units for OPC 40082-3 Category Title Description Server OPC 40082-3 Basic Support
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systems18.1 Conformance UnitsConformance Units This chapter defines the corresponding Conformance Unit for OPC 40082-4. Table 41 - Conformance Units for OPC 40082-4 Category Title Description Server OPC 40082-4 Basic Support
-
OPC-40084-3 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 3: ExtruderConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-3. Table 6 - Conformance Units for OPC 40084-3 Category Title Description Server OPC 40084-3 Basic Support
-
OPC-40084-4 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 4: Haul-offConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-4. Table 4 - Conformance Units for OPC 40084-4 Category Title Description Server OPC 40084-4 Basic Support
-
OPC-40084-5 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 5: Melt pumpConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-5. Table 2 - Conformance Units for OPC 40084-5 Category Title Description Server OPC 40084-5 Basic Support
-
OPC-40084-6 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 6: FilterConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-6. Table 5 - Conformance Units for OPC 40084-6 Category Title Description Server OPC 40084-6 Basic Support
-
OPC-40084-7 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 7: DieConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-7. Table 2 - Conformance Units for OPC 40084-7 Category Title Description Server OPC 40084-7 Basic Support
-
OPC-40084-8 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 8: PelletizerConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-8. Table 4 - Conformance Units for OPC 40084-8 Category Title Description Server OPC 40084-8 Basic Support
-
OPC-40084-9 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 9: CutterConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-9. Table 8 - Conformance Units for OPC 40084-9 Category Title Description Server OPC 40084-9 Basic Support
-
OPC-40084-10 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 10: CalibratorConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-10. Table 4 - Conformance Units for OPC 40084-10 Category Title Description Server OPC 40084-10 Basic Support
-
OPC-40084-11 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 11: CorrugatorConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-11. Table 2 - Conformance Units for OPC 40084-11 Category Title Description Server OPC 40084-11 Basic Support
-
OPC-40084-12 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 12: CalenderConformance Units This chapter defines the corresponding Conformance Unit for OPC 40084-12. Table 4 - Conformance Units for OPC 40084-12 Category Title Description Server OPC 40084-12 Basic Support
-
OPC-40301 – OPC UA for Flat Glass Processing3.5.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40444 – OPC UA for Textile Testing Devices3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Base3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: General3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40504-1 – OPC UA for Cutting Tools - Part 1: Manufacturing3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40530 – OPC UA for Laser Systems3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical Interface3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel. NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit, one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40560 – OPC UA for Mining - General3.2.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40570 – OPC UA for Wire Harness Manufacturing3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40700 – OPC UA for Surface Technology - General Types3.3.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply Systems3.3.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting Machinery3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40719 – OPC UA for Plasma Surface Technology3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)3.4.1.1 Node definitionsConformanceUnits are defined at the end of the tables defining Nodes , one row per ConformanceUnit . The ConformanceUnits are reflected in the Category element for the Node definition in the UANodeSet ... AccessLevel . NOTE Notes referencing footnotes of the table content. Conformance Units Name of ConformanceUnit , one row per ConformanceUnit Components of Nodes can be complex that is containing components by themselves