8.2.2 Server Facets
8.2.2.1 Overview
The following sections specify the Facets available for Servers that implement the Industrial Automation companion specification. Each section defines and describes a Facet or Profile.
8.2.2.2 IA Stacklight Server Profile
Table 62 defines a Profile that describes the capability of a Server to provide stacklight information.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA Stacklight | M |
8.2.2.3 IA Statistical Data Server Profile
Table 63 defines a Profile that describes the capability of a Server to provide statistical data.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA Statistical Data | M |
8.2.2.4 IA CT Reusable Calibration Target Handling Server Facet
This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type ReusableCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.
Table 62 defines Conformance Units of the Facet.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA CT Base Elements | M |
| IA | IA CT Reusable Calibration Target | M |
| IA | IA CT Manufactured Target | M |
| IA | IA CT Quality Controlled Target | O |
| IA | IA CT Validated Target | M |
| IA | IA CT Distinct Quantity Value Target | O |
| IA | IA CT Quantity Range Target | O |
| IA | IA CT Custom Featured Target | O |
8.2.2.5 IA CT Reusable Device Calibration Target Handling Server Facet
This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type ReusableDeviceCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.
Table 65 defines Conformance Units of the Facet.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA CT Base Elements | M |
| IA | IA CT Reusable Device Calibration Target | M |
| IA | IA CT Manufactured Target | M |
| IA | IA CT Quality Controlled Target | O |
| IA | IA CT Validated Target | M |
| IA | IA CT Distinct Quantity Value Target | O |
| IA | IA CT Quantity Range Target | O |
| IA | IA CT Custom Featured Target | O |
8.2.2.6 IA CT One-Time Calibration Target Handling Server Facet
This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type OneTimeCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.
Table 66 defines Conformance Units of the Facet.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA CT Base Elements | M |
| IA | IA CT One-Time Calibration Target | M |
| IA | IA CT Manufactured Target | O |
| IA | IA CT Validated Target | O |
| IA | IA CT Distinct Quantity Value Target | O |
| IA | IA CT Quantity Range Target | O |
| IA | IA CT Custom Featured Target | O |
8.2.2.7 IA CT Dynamic Calibration Target Handling Server Facet
This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type DynamicCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.
Table 62 defines Conformance Units of the Facet.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| IA | IA CT Base Elements | M |
| IA | IA CT Dynamic Calibration Target | M |
| IA | IA CT Manufactured Target | O |
| IA | IA CT Distinct Quantity Value Target | O |
| IA | IA CT Quantity Range Target | O |
| IA | IA CT Custom Featured Target | O |
8.2.2.8 IA CT Full Calibration Target Handling Server Facet
This Facet describes that a Server supports calibration targets of the categories: reusable calibration targets, reusable device calibration targets, one-time calibration targets and dynamic calibration targets.
Table 62 defines contained Facets of the Facet.
| Group | Conformance Unit / Profile Title | Mandatory / Optional |
| Profile | IA CT Reusable Calibration Target Handling Server Facet | |
| Profile | IA CT Reusable Device Calibration Target Handling Server Facet | |
| Profile | IA CT One-Time Calibration Target Handling Server Facet | |
| Profile | IA CT Dynamic Calibration Target Handling Server Facet |