8.2.2 Server Facets

8.2.2.1 Overview

The following sections specify the Facets available for Servers that implement the Industrial Automation companion specification. Each section defines and describes a Facet or Profile.

8.2.2.2 IA Stacklight Server Profile

Table 62 defines a Profile that describes the capability of a Server to provide stacklight information.

Table 62 – IA Stacklight Server Profile
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA StacklightM
8.2.2.3 IA Statistical Data Server Profile

Table 63 defines a Profile that describes the capability of a Server to provide statistical data.

Table 63 – IA Statistical Data Server Profile
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA Statistical DataM
8.2.2.4 IA CT Reusable Calibration Target Handling Server Facet

This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type ReusableCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.

Table 62 defines Conformance Units of the Facet.

Table 64 – IA CT Reusable Calibration Target Handling Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA CT Base ElementsM
IAIA CT Reusable Calibration TargetM
IAIA CT Manufactured TargetM
IAIA CT Quality Controlled TargetO
IAIA CT Validated TargetM
IAIA CT Distinct Quantity Value TargetO
IAIA CT Quantity Range TargetO
IAIA CT Custom Featured TargetO
8.2.2.5 IA CT Reusable Device Calibration Target Handling Server Facet

This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type ReusableDeviceCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.

Table 65 defines Conformance Units of the Facet.

Table 65 – IA CT Reusable Device Calibration Target Handling Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA CT Base ElementsM
IAIA CT Reusable Device Calibration TargetM
IAIA CT Manufactured TargetM
IAIA CT Quality Controlled TargetO
IAIA CT Validated TargetM
IAIA CT Distinct Quantity Value TargetO
IAIA CT Quantity Range TargetO
IAIA CT Custom Featured TargetO
8.2.2.6 IA CT One-Time Calibration Target Handling Server Facet

This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type OneTimeCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.

Table 66 defines Conformance Units of the Facet.

Table 66 – IA CT One-Time Calibration Target Handling Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA CT Base ElementsM
IAIA CT One-Time Calibration TargetM
IAIA CT Manufactured TargetO
IAIA CT Validated TargetO
IAIA CT Distinct Quantity Value TargetO
IAIA CT Quantity Range TargetO
IAIA CT Custom Featured TargetO
8.2.2.7 IA CT Dynamic Calibration Target Handling Server Facet

This Facet describes that a Server supports calibration targets of category reusable calibration targets. All instances of CalibrationTargetType or a subtype in the Server having the CalibrationTargetCategory of type DynamicCalibrationTargetCategoryType or a subtype shall support the requirements as defined in the mandatory Conformance Units, and optionally the optional Conformance Units. Each of those instances shall support at least one of the following optional Conformance Units IA CT Distinct Quantity Value Target, IA CT Quantity Range Target or IA CT Custom Featured Target.

Table 62 defines Conformance Units of the Facet.

Table 67 – IA CT Dynamic Calibration Target Handling Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
IAIA CT Base ElementsM
IAIA CT Dynamic Calibration TargetM
IAIA CT Manufactured TargetO
IAIA CT Distinct Quantity Value TargetO
IAIA CT Quantity Range TargetO
IAIA CT Custom Featured TargetO
8.2.2.8 IA CT Full Calibration Target Handling Server Facet

This Facet describes that a Server supports calibration targets of the categories: reusable calibration targets, reusable device calibration targets, one-time calibration targets and dynamic calibration targets.

Table 62 defines contained Facets of the Facet.

Table 68 – IA CT Reusable Calibration Target Handling Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
ProfileIA CT Reusable Calibration Target Handling Server Facet
ProfileIA CT Reusable Device Calibration Target Handling Server Facet
ProfileIA CT One-Time Calibration Target Handling Server Facet
ProfileIA CT Dynamic Calibration Target Handling Server Facet