Search
71 result(s) for BaseEventType
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.2 BaseEventTypeBaseEventType This EventType is defined in OPC 10000-3 . Its representation in the AddressSpace is formally defined in Table 25 . Table 25 - BaseEventType definition Attribute Value BrowseName BaseEventType IsAbstract True ... specific to a Node the NodeId is set to null. Some subtypes of this BaseEventType may define additional rules for the SourceNode Property . SourceName provides a description of the source
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.7.2 EventTypesspecific EventType . A Server may support many types. This part defines the BaseEventType that all other EventTypes derive from. It is expected that other companion specifications will define additional EventTypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.15 GeneratesEventTargetNode of this ReferenceType shall be an ObjectType representing EventTypes , that is, the BaseEventType or one of its subtypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.16 AlwaysGeneratesEventTargetNode of this ReferenceType shall be an ObjectType representing EventTypes , that is, the BaseEventType or one of its subtypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model9.2 BaseEventTypeBaseEventType The BaseEventType defines all general characteristics of an Event . All other EventTypes derive from it. There is no other semantic associated with this type
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.4.5 SimpleAttributeOperandsubtypes. If the SimpleAttributeOperand is used in an EventFilter and the typeDefinitionId is BaseEventType the Server shall evaluate the browsePath without considering the typeDefinitionId . browsePath [] QualifiedName A relative path
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.22.3 EventFiltersame SimpleAttributeOperand . browsePath will apply to multiple EventTypes . If the Client specifies the BaseEventType in the SimpleAttributeOperand.typeDefinitionId then the Server shall evaluate the SimpleAttributeOperand.browsePath without considering the SimpleAttributeOperand.typeDefinitionId . Each InstanceDeclaration ... description of this result code. The typeId is not the NodeId for BaseEventType or a subtype of it. Bad_NodeIdUnknown See Table 179 for the description of this result code
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.3 AuditEventTypeBrowseName AuditEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable ActionTimeStamp ... Auditing History Services Auditing Write Auditing Method This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The BaseEventType Properties are used to describe the source
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.28 SystemEventTypeValue BrowseName SystemEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Status Underlying System Base Info System Status This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . There are no additional Properties defined for this EventType
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.31 BaseModelChangeEventTypeValue BrowseName BaseModelChangeEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Info Model Change This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . There are no additional Properties defined for this EventType . The SourceNode Property
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.33 SemanticChangeEventTypeValue BrowseName SemanticChangeEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable Changes ... PropertyType Mandatory Conformance Units Base Info SemanticChange This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.34 EventQueueOverflowEventTypeValue BrowseName EventQueueOverflowEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Info EventQueueOverflow EventType This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall be assigned
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.35 ProgressEventTypeValue BrowseName ProgressEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable Context ... Mandatory Conformance Units Base Info Progress Events This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model8.2.6 ObjectTypesindustry, such as the ServerType defined in 6.3.1 . This Object also indirectly references the BaseEventType defined in 6.4.2 , which is the base type of all EventTypes . Thereby
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions4.2 Conditionsspecific ConditionType . The ConditionType and derived types are sub-types of the BaseEventType (see 10000-3 and 10000-5 ). This part defines types that are common across many industries
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.1 Generalbase Event model by defining various Event Types based on the BaseEventType . All of the Event Types defined in this document can be further extended from domain to Server specific
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.1 Generalintroduces the concept of states differentiating it from the base Event model. Unlike the BaseEventType , Conditions are not transient. The ConditionType is further extended into Dialog and AcknowledgeableConditionType , each
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypeValue BrowseName ConditionType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 10000-5 HasSubtype ObjectType DialogConditionType Defined in Clause 5.6.2 HasSubtype ObjectType AcknowledgeableConditionType Defined ... column indicates that no ModellingRule applies. The ConditionType inherits all Properties of the BaseEventType . Their semantic is defined in 10000-5 . SourceNode Property identifies the ConditionSource . See 5.12 for more
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.2.3 Event categoriesServer are represented in the UA Server as ObjectTypes which are subtypes of BaseEventType . The BrowseName and DisplayName of the ObjectType Node for Simple and Tracking Event Types are constructed ... Wrapper does not know these semantics then Simple Event Types are subtypes of BaseEventType , Tracking Event Types are subtypes of AuditEventType and Condition Event Types are subtypes of the AlarmType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.3.3 Event Type mappingType mapping Since all Alarms and Conditions Event s belong to a subtype of BaseEventType , the A&E COM UA Proxy maps the subtype as received from
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.3.4 Event category mappingconsist of the set of Event types defined in the hierarchy of subtypes of BaseEventType excluding AuditEventType and ConditionType and their respective subtypes. Figure D.3 - Example mapping of UA Event
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsfollowing items are present for all A&E event types szSource UA BaseEventType Property: SourceName ftTime UA BaseEventType Property: Time szMessage UA BaseEventType Property: Message dwEventType See Clause D.3.3 ... dwEventCategory See Clause D.3.4 dwSeverity UA BaseEventType Property: Severity dwNumEventAttrs Calculated within A&E COM UA Proxy pEventAttributes Constructed within A&E COM UA Proxy The following items
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessshall include at least the event fields Time , SourceName and Severity of the BaseEventType Type defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.13.3 PubSubCommunicationFailureEventTypeThis EventType inherits all Properties of the PubSubStatusEventType . The Message Event field inherited from BaseEventType has a localized description of the error. The Error Property has the StatusCode associated with
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.6 FiniteStateMachineTypeEvent . The Event is indicated by a HasEffect Reference to a subtype of BaseEventType . The StateMachineType shall have GeneratesEvent References to the targets of a HasEffect Reference for each
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.17 TransitionEventTypeTransitionEventType The TransitionEventType is a subtype of the BaseEventType . It can be used to generate an Event identifying that a Transition of a StateMachine was triggered. It is formally defined ... BrowseName TransitionEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the base BaseEventType defined in OPC 10000-5 HasComponent Variable Transition LocalizedText TransitionVariableType Mandatory HasComponent Variable FromState LocalizedText
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Modelinclusive and corresponds to the range provided in the OPC UA BaseEventType (see OPC 10000-3 ). Additional details for mapping of the severity defined for OPC BaseEvents to LogRecords ... Describes the specific type of Event. It corresponds to the EventType field defined in BaseEventType . If AdditionalData is provided then an EventType should be provided. True SourceNode 0:NodeId Identifies
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject ModelEvent to have a ConditionClassId or SubConditionClassId of LogEntryConditionClass . The following describes fields in BaseEventType that are mapped to a LogRecord : Time - the time associated with this event. EventType ... defined in BaseEventType in OPC 10000-5 SourceNode - identifies the Node that the Event originated from, as defined in BaseEventType in OPC 10000-5 . For LogObject Events , this node
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.3 BaseLogEventTypeBaseLogEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseEventType defined in OPC 10000-5 . 0:HasProperty Variable ErrorCode 0:StatusCode 0:PropertyType O 0:HasProperty ... specific Node is related to the LogRecord . The ConditionClassId and ConditionClassName in BaseEventType are made mandatory in this EventType . The ConditionClassId shall be set to LogEntryConditionClassType . TraceContext is an instance
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionConfigurationSetEventType is formally defined in Table 112 . It is a subtype of the BaseEventType defined in OPC 10000-5 . This new type does not add any additional information ... BaseEventType besides the semantics that an Event was generated by the ConnectionConfigurationSetStateMachineType . Table 112 - ConnectionConfigurationSetEventType Attribute Value BrowseName 4:ConnectionConfigurationSetEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicsmaintenance activity should be put into the Message field defined for the BaseEventType in OPC 10000-5 . The maintenance activity starts, when the MaintenanceState changes to Execution, and finished, when
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job ControlISA95JobOrderStatusEventType IsAbstract True References NodeClass BrowseName Data Type TypeDefinition Other Subtype of the 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable JobOrder ISA95JobOrderDataType 0:PropertyType M 0:HasProperty
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId DevicesLogbook will be provided in the Event field Message defined by the BaseEventType
-
OPC-30060 – OPC UA for Tobacco Machine CommunicationValue BrowseName LogbookEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the BaseEventType defined in OPC 10000-5: OPC Unified Architecture Part 5: Information Model, which means ... Instance Declarations of that Node. Please note that Time and Message belong to BaseEventType
-
OPC-30140 – OPC UA for PROFINET6.3.4.2 PnAssetChangedEventTypeBrowseName PnAssetChangedEventType IsAbstract False References Node Class BrowseName DataType TypeDefinition Modelling Rule Subtype of BaseEventType defined in [OPC 10000-5] . HasProperty Variable AssetType PnAssetTypeEnumeration PropertyType Mandatory HasProperty Variable AssetChange PnAssetChangeEnumeration
-
OPC-30140 – OPC UA for PROFINET6.3.4.3 PnTopologyChangedEventTypeThis means that the physical network topology has changed. The Severity variable (inherited from BaseEventType) shall be set to 1. Table 104 - PnTopologyChangedEventType Definition Attribute Value BrowseName PnTopologyChangedEventType IsAbstract False ... References Node Class BrowseName DataType TypeDefinition Modelling Rule Subtype of BaseEventType defined in [OPC 10000-5] . The SourceNode variable of the event includes the NodeId of the PnPortType object
-
OPC-30142 – OPC UA for PROFINET Remote IORioChannelDiagnosisEventType The RioChannelDiagnosisEventType is a subtype of 0:BaseEventType . The Server may support durable mode for Subscriptions (see section 12.1 ). MonitoredItem data are delivered and event queues are stored ... Value BrowseName RioChannelDiagnosisEventType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of BaseEventType defined in [OPC 10000-5]. 0:HasProperty Variable RioChannelNumber 0:UInt16 0:PropertyType
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valuesadjustment took place References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseEventType defined in OPC 10000-5 0:HasProperty Variable ZeroPointAdjustmentResult 0:StatusCode 0:PropertyType M Conformance ... Units Machinery Process Values Base EventTypes This EventType inherits all Properties of the BaseEventType . The 0:SourceNode and 0:SourceName shall be set to the Object the zero-adjustment
-
OPC-40001-101 – OPC UA for Machinery - Part 101: Result Transferpartial result. References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseEventType defined in OPC 10000-5 0:HasComponent Variable Result ResultDataType ResultType M Conformance Units Machinery-Result ... ResultEvents This EventType inherits all Properties of the BaseEventType . The Result Variable of ResultType VariableType contains the subvariables as defined by the ResultType . Clients can select some of those individually
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices11 Alarmsdevice. For unique identification of the alarm event, the SourceNode (included in BaseEventType ) of the device needs to be sent for every alarm message. The SourceNode includes the namespace number ... MonitoredParameterType if this is out of tolerance). For the Severity Property (included in BaseEventType ) the following classes shall be used: Table 22 - Severity Classes Range of Severity Description
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices18.2 ZoneAlarmTypeTypeDefinition Other Subtype of 3:HelpOffNormalAlarmType defined in OPC 40083 The SourceNode (included in BaseEventType ) shall contain the NodeId of the related zone. In case of medium or high severity
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing SystemsBrowseName LDSCycleParametersEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC UA Part 5 0:HasProperty Variable CycleNumber 0:UInt64 0:PropertyType
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems12.1 ComponentAlarmTypedefined in OPC 40083 Conformance Units OPC 40082-3 Alarms The SourceNode (included in BaseEventType ) shall contain the NodeId of the related component. In case of medium or high severity
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems12.2 AdditiveAlarmTypedefined in OPC 40083 Conformance Units OPC 40082-3 Alarms The SourceNode (included in BaseEventType ) shall contain the NodeId of the related additive. In case of medium or high severity
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systemsdiagnostic events. In the case of Component related messages, the SourceNode (included in BaseEventType ) shall contain the NodeId of the related component. In case of medium or high severity
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsSeverity property is used (e.g. in MESMessage in 14.4 , all events based on BaseEventType ), the following classification shall be used: Table 9 - Severity Classes Range of Severity Description
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsBrowseName LogbookEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0:BaseEventType defined in OPC UA Part 5 0:HasComponent Object User UserType M 0:HasProperty Variable ... NOTE: The EventSource , Time and a Message are already included in the BaseEventType of OPC UA. There shall be a buffer to be accessible via the OPC UA service history
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions9.15 UserFeedbackLogTypeSpecification (e.g. IMMMessageClassificationEnumeration in OPC 40077). NOTE: The Message itself is included in the BaseEventType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions14.5 SetMESMessageprocessing of the message) Message Text of Message Severity Severity as defined in the BaseEventType (1 = low - 1000 = high) Table 47 - SetMESMessage Method AddressSpace Definition Attribute Value BrowseName SetMESMessage References
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions14.8 MessageConditionTypemessage has led to a standstill. NOTE: The AlarmConditionType is a subtype of BaseEventType and therefore includes the Properties Severity and Message (= text
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions26.1 ActiveErrorDataTypeString Unique identifier defined by manufacturer Severity 0:UInt16 Severity as defined in the BaseEventType (1 = low - 1000 = high) Message 0:LocalizedText Message giving information about the error
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion LineBrowseName JobGroupStatusChangedEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable Id 0:String 0:PropertyType ... Status Property of the job group after the change The SourceNode (part of BaseEventType ) shall be the NodeId of the relevant job group
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion Line8.3.17 JobStatusChangedEventTypeBrowseName JobStatusChangedEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable JobGroupId 0:String 0:PropertyType ... Status Property of the job group after the change The SourceNode (part of BaseEventType ) shall be the NodeId of the relevant
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion Line8.3.18 UnitFinishedEventTypeBrowseName UnitFinishedEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable JobGroupId 0:String 0:PropertyType ... GoodProduct : Information if the finished unit has a good quality. The SourceNode (part of BaseEventType ) shall be the NodeId of the relevant
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion Line8.3.19 LotFinishedEventTypeBrowseName LotFinishedEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable JobGroupId 0:String 0:PropertyType ... been finished. (e.g. lot number 6 roll is finished) The SourceNode (part of BaseEventType ) shall be the NodeId of the relevant job. NOTE: The three events JobStatusChanged , UnitFinished and LotFinished
-
OPC-40084-9 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 9: Cutter6.12 CutEventTypeBrowseName CutEventType IsAbstract True References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseEventType defined in OPC 10000-5 0:HasProperty Variable CuttingProductId 0:String 0:PropertyType
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.8.1 RecipePreparedEventTypeRecipePreparedEventType RecipePreparedEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event shall be triggered by the server when the preparation of a recipe is completed ... Value BrowseName RecipePreparedEventType IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in OPC 10000-5 HasProperty Variable ExternalId RecipeIdExternalDataType PropertyType Optional HasProperty Variable InternalId RecipeIdInternalDataType
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.8.2 JobStartedEventTypeJobStartedEventType JobStartedEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event is to be triggered by the server when the state machine transitions from the Ready ... machines in the same server, the client can use the Source property inherited from BaseEventType to identify the state machine instance the event originated from. Figure 28 - Overview JobStartedEventType Table
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.8.3 ReadyEventTypeReadyEventType ReadyEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event is to be triggered by the server when the state machine transitions to the Ready ... machines in the same server, the client can use the Source property inherited from BaseEventType to identify the state machine instance the event originated from. Figure 29 - Overview ReadyEventType Table
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.8.5 AcquisitionDoneEventTypeAcquisitionDoneEventType AcquisitionDoneEventType is an EventType subtype of BaseEventType, defined in OPC 10000-5 . This event is to be triggered by the server. when the vision system finishes a data acquisition ... machines in the same server, the client can use the Source property inherited from BaseEventType to identify the state machine instance the event originated from. Figure 31 - Overview AcquisitionDoneEventType Table
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.4.7.1 EnterStepSequenceEventTypeEnterStepSequenceEventType EnterStepSequenceEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event is to be triggered by the server when in the Entry state the decision ... Value BrowseName EnterStepSequenceEventType IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in OPC 10000-5 HasProperty Variable Steps Int32 PropertyType Mandatory
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.4.7.2 NextStepEventTypeNextStepEventType NextStepEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event is to be triggered by the server when in the Step state the decision ... Value BrowseName NextStepEventType IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in OPC 10000-5 HasProperty Variable Step Int32 PropertyType Mandatory
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.4.7.3 LeaveStepSequenceEventTypeLeaveStepSequenceEventType LeaveStepSequenceEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 , this event is to be triggered by the server when in the Step state the decision ... Value BrowseName LeaveStepSequenceEventType IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management11.4.1.2 Usage of inherited propertiesUsage of inherited properties The following properties are inherited from BaseEventType and shall be used in VisionEventType in the manner described here. SourceNode Reference to the source of the Message
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management11.4.1.3 Usage of additional propertiesfollowing describes the usage of the properties added by VisionEventType with respect to BaseEventType . CausePath Path information string based on the E10 scheme described in 11.6 or an application specific
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management11.4.8 VisionSafetyEventTypeVisionSafetyEventType VisionSafetyEventType is an EventType subtype of BaseEventType , defined in OPC 10000-5 . This event is to be triggered by the server when a safety-related incident occurs ... Value BrowseName VisionSafetyEventType IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in OPC 10000-5 HasProperty Variable VisionSafetyTriggered Boolean PropertyType Mandatory HasProperty Variable VisionSafetyInformation String
-
OPC-40200 – OPC UA for Weighing Technology8.1.1 OverviewOverview The ScaleEventType is a subtype of the BaseEventType , which it extends with some Properties . It should be used for all Events that are relevant to the weighing technology. Figure
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information Model6.11.1 Generalexample for using the CncMessageType . As CncMessageType is derived from the OPC UA BaseEventType , it shall be used in most parts as specified in OPC 10000-5 . Figure 19 gives
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: General8.1 CyclicEventTypeBrowseName CyclicEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0: BaseEventType defined OPC 10000-5 , which means it inherits the InstanceDeclarations of that Node. 0:HasComponent
-
OPC-40570 – OPC UA for Wire Harness ManufacturingBrowseName ProductFinishedEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0: BaseEventType defined in OPC 10000-3, which means it inherits the InstanceDeclarations of that Node
-
OPC-40570 – OPC UA for Wire Harness Manufacturing11.2 RunCompleteEventTypeBrowseName RunCompleteEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0: BaseEventType defined in OPC 10000-3., which means it inherits the InstanceDeclarations of that Node