7.3.2 SetTriggerSettings

The Method SetTriggerSettings enables to adjust the trigger settings of the relevant sensor of the WMTP. TriggerSettings represents the time period from one measurement point to the next. If the relevant sensor of the WMTP does not define the measurement triggering using the TriggerSettings, the default value 0 shall be assumed.

Signature

	SetTriggerSettings (
		[in]	0:Duration	TriggerDuration
	);
	
Table 51 – SetTriggerSettings Method Arguments
Argument Description
TriggerDurationThis Duration represents the time period between measurements.
Table 52 – SetTriggerSettings Method AddressSpace Definition
Attribute Value
BrowseNameSetTriggerSettings
References Node Class BrowseName DataType TypeDefinition Other
0:HasPropertyVariableInputArgumentsArgument[]0:PropertyTypeM