17 TemperatureRiseMonitoringType

At maximum controller output, the temperature value must change in a given time by a specified value, otherwise there is an error in the measuring circuit.

Table 21 – TemperatureRiseMonitoringType Definition
Attribute Value
BrowseNameTemperatureRiseMonitoringType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5
0:HasPropertyVariableSetValueActive0:Boolean0:PropertyTypeM, RW
0:HasPropertyVariableErrorDetected0:Boolean0:PropertyTypeM, RO
0:HasPropertyVariableSupervisionTime0:Duration0:PropertyTypeO, RW
0:HasComponentVariableSetValueTemperatureChange0:Double0:AnalogItemTypeO, RW

17.1 SetValueActive

On / Off for the TemperatureRiseMonitoring.

17.2 ErrorDetected

Result of the TemperatureRiseMonitoring.

17.3 SupervisionTime

Specification of the time within the temperature must have changed.

17.4 SetValueTemperatureChange

Specification of the set value change

Unit: °C or F