OPC Unified Architecture – Part 211: Global Positioning
7 OPC UA ObjectTypes
7.1 ZoneType definition
7.1.1 Overview
The ZoneType defines an area, in which a local location is computed, e.g. via a RTLS or a proximity based system like RFID. For that reason, it might either have a set of GroundControlPoints defining the extent for RTLS or just a point and a radius for proximity based systems. It is formally defined in Table 15.
7.1.2 ObjectType definition
Table 15 – ZoneType definition
Attribute
Value
BrowseName
ZoneType
IsAbstract
False
Description
Defines an area, in which a local location is computed, e.g. via a RTLS or an proximity based system like RFID. For that reason it might have a set of GroundControlPoints defining the extent or just a point and a radius.
References
Node Class
BrowseName
DataType
TypeDefinition
Other
Subtype of the 0:BaseObjectType
0:HasProperty
Variable
ZoneId
0:String
0:PropertyType
M
0:HasProperty
Variable
Building
0:String
0:PropertyType
O
0:HasProperty
Variable
Floor
0:String
0:PropertyType
O
0:HasProperty
Variable
Site
0:String
0:PropertyType
O
0:HasComponent
Variable
GroundControlPoints
GroundControlPointDataType[]
0:BaseDataVariableType
O
0:HasComponent
Variable
Position
3DGeographicCoordinateDataType
0:BaseDataVariableType
O
0:HasComponent
Variable
Radius
0:Double
0:BaseDataVariableType
O
0:HasProperty
Variable
IncompleteConfiguration
0:Boolean
0:PropertyType
O
Conformance Units
GPOS Zones
The child Nodes of the ZoneType have additional Attribute values defined in Table 16.
Table 16 – ZoneType Attribute values for child Nodes
BrowsePath
Description Attribute
ZoneId
A unique identifier of the zone (e.g. a GUID).
Building
Name of the building
Floor
Name of the floor
Site
Name of the site
GroundControlPoints
Points defining the extent of the zone
Position
Describes a point (i.e. a position) in 2 or 3 dimensions.
Radius
For proximity-based systems. Describes the zone as a circular region with a given radius in meters around the position.
IncompleteConfiguration
Indicates if the configuration is complete. FALSE if configuration is complete.