OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition MonitoringVisionSystemAssetType ObjectType DefinitionThe VisionSystemAssetType is an ObjectType that provides a representation of the machine vision system and organizes the items that constitute it into different folders depending on their ... vision system as an asset. It is formally defined in Table 21 . Table 21 - VisionSystemAssetType Definition Attribute Value BrowseName VisionSystemAssetType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringpoint to the functional view of a machine vision system. This specification introduces the VisionSystemAssetType , an instance of which shall provide an additional entry point into the inner structure ... machine vision system. The VisionSystemAssetType represents the composition of the machine vision system, i.e., it shows which components and other machines together build up the machine vision system. An instance
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the ComputingDevices folder of the VisionSystemAssetType . It is formally defined in Table 24 . Figure 14 - IComputingDeviceType Table 24 - IComputingDeviceType Definition Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the ComputingDevices folder of the VisionSystemAssetType . It is formally defined in Table 26 . Figure 15 - VisionComputingDeviceType Table 26 - VisionComputingDeviceType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the DisplayUnits folder of the VisionSystemAssetType . It is formally defined in Table 27 . Figure 16 - IDisplayUnitType Table 27 - IDisplayUnitType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the DisplayUnits folder of the VisionSystemAssetType . It is formally defined in Table 29 . Figure 17 - VisionDisplayUnitType Table 29 - VisionDisplayUnitType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the PhysicalInterfaces folder of the VisionSystemAssetType . It is formally defined in Table 30 . Figure 18 - IPhysicalInterfaceType Table 30 - IPhysicalInterfaceType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the PhysicalInterfaces folder of the VisionSystemAssetType . It is formally defined in Table 32 . Figure 19 - VisionPhysicalInterfaceType Table 32 - VisionPhysicalInterfaceType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the Lenses folder of the VisionSystemAssetType . It is formally defined in Table 33 . Figure 20 - ILensType Table 33 - ILensType Definition Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the Lenses folder of the VisionSystemAssetType . It is formally defined in Table 36 . Figure 21 - VisionLensType Table 36 - VisionLensType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the LensControllers folder of the VisionSystemAssetType . It is formally defined in Table 37 . Figure 22 - VisionLensControllerType Table 37 - VisionLensControllerType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the LightingControllers folder of the VisionSystemAssetType . It is formally defined in Table 38 . Figure 23 - ILightingControllerType Table 38 - ILightingControllerType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the LightingControllers folder of the VisionSystemAssetType . It is formally defined in Table 41 . Figure 24 - VisionLightingControllerType Table 41 - VisionLightingControllerType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the Lamps folder of the VisionSystemAssetType . It is formally defined in Table 42 . Figure 25 - ILampType Table 42 - ILampType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the Lamps folder of the VisionSystemAssetType . It is formally defined in Table 44 . Figure 26 - VisionLampType Table 44 - VisionLampType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the ImageSensors folder of the VisionSystemAssetType . It is formally defined in Table 45 . Figure 27 - VisionImageSensorType Table 45 - VisionImageSensorType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the FrameGrabbers folder of the VisionSystemAssetType . It is formally defined in Table 46 . Figure 28 - VisionFrameGrabberType Table 46 - VisionFrameGrabberType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the OpticalFilters folder of the VisionSystemAssetType . It is formally defined in Table 47 . Figure 29 - VisionOpticalFilterType Table 47 - VisionOpticalFilterType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the WayEncoders folder of the VisionSystemAssetType . It is formally defined in Table 48 . Figure 30 - VisionWayEncoderType Table 48 - VisionWayEncoderType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the TriggerSensors folder of the VisionSystemAssetType . It is formally defined in Table 49 . Figure 31 - VisionTriggerSensorType Table 49 - VisionTriggerSensorType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the PatternGenerators folder of the VisionSystemAssetType . It is formally defined in Table 50 . Figure 32 - VisionPatternGeneratorType Table 50 - VisionPatternGeneratorType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the AcquisitionBackgrounds folder of the VisionSystemAssetType . It is formally defined in Table 51 . Figure 33 - VisionAcquisitionBackgroundType Table 51 - VisionAcquisitionBackgroundType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the SurroundingEnviroment folder of the VisionSystemAssetType and contains information about the surrounding environment of the vision system. It is formally defined
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the Housings folder of the VisionSystemAssetType . It is formally defined in Table 53 . Figure 35 - VisionHousingType Table 53 - VisionHousingType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the PowerSupplies folder of the VisionSystemAssetType . It is formally defined in Table 54 . Figure 36 - VisionPowerSupplyType Table 54 - VisionPowerSupplyType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the ClimateControllers folder of the VisionSystemAssetType . It is formally defined in Table 55 . Figure 37 - VisionClimateControllerType Table 55 - VisionClimateControllerType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the Licenses folder of the VisionSystemAssetType . It is formally defined in Table 56 . Figure 38 - ILicenseType Table 56 - ILicenseType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the Licenses folder of the VisionSystemAssetType . It is formally defined in Table 58 . Figure 39 - VisionLicenseType Table 58 - VisionLicenseType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the NetworkDevices folder of the VisionSystemAssetType . It is formally defined in Table 59 . Figure 40 - VisionNetworkDeviceType Table 59 - VisionNetworkDeviceType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringobjects that implement this interface shall be organized in the Cables folder of the VisionSystemAssetType . It is formally defined in in Table 60 . Figure 41 - ICableType Table 60 - ICableType Definiton
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the Cables folder of the VisionSystemAssetType . It is formally defined in Table 63 . Figure 42 - VisionCableType Table 63 - VisionCableType Definiton Attribute
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoringinstances of this object type shall be organized in the OtherOpticalEquipments folder of the VisionSystemAssetType . It is formally defined in Table 55 . Figure 43 - VisionOtherOpticalEquipmentType Table 64 - VisionOtherOpticalEquipmentType Definiton Attribute