Search
53 result(s) for Folder
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Modelother semantic than organizing of the AddressSpace . A special ReferenceType is introduced for those Folder Objects , the Organizes ReferenceType . The SourceNode of such a Reference should always be a View
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesB.3.2 Used type modelAmount" (Stored as an Int32 ). AreaType derived from BaseObjectType is just a simple Folder and contains no Properties . This example type system is shown in Figure B.3 . In this
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model8.2.9 DataTypesdirectly from the "DataTypes" Object to the DataType Nodes or using additional Folder Objects for grouping purposes. The intent is that all DataTypes of the Server exposed
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessQuantityType defines a model for physical quantities. These are listed in the Quantites Folder . Each quantity has a ServerUnits Folder in which the units, referenced by EngineeringUnit Properties with HasEngineeringUnitDetails
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.2 Branchpart of the NodeId for each Branch. See also clause A.3.1.5 . An OPC UA Folder representing a DA Branch uses the Organizes References to reference child DA Branches and uses
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessdefined in OPC 10000-13 . If the Server does not support Aggregates the Folder is left empty. The ServerTimestampSupported indicates the Server supports the storage of ServerTimestamps . If this Variable
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Servicesused to get the list of GDS managed CertificateGroups by browsing the CertificateGroups Folder of the Directory Object . If more than one CertificateGroup is returned, the user selects the relevant
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.7.1 OverviewClient, executes against the ServerConfiguration Object or a BaseApplicationConfiguration Object in the ManagedApplications Folder
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Serviceswell-known ServerConfiguration Object or one of the ApplicationConfigurationType instances in the ManagedApplications Folder . The list of CertificateGroups to update may be specified by an administrator or discovered by browsing ... Certificates needed to trust the CertificateManager. An application being configured via the ManagedApplications Folder does not need to trust the CertificateManager Certificate Update Required? For each CertificateType in a CertificateGroup
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.1 Overviewsupports Push Management The ServerConfiguration Object is used to manage the Server . The ManagedApplications Folder collects ApplicationConfiguration Objects for other applications which the Server is able to manage. For example
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesApplicationConfigurationFolderType A Folder for ApplicationConfiguration Objects which a Server exposes in its AddressSpace . Table 100 - ApplicationConfigurationFolderType Definition Attribute Value BrowseName 0:ApplicationConfigurationFolderType IsAbstract False References NodeClass BrowseName DataType Type Definition
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.5.1 Overviewwhen they request or revoke KeyCredentials for themselves or for another application. The KeyCredentialManagement Folder is a well-known Object that appears in the AddressSpace of any Server which supports
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesKeyCredentialManagementFolderType This ObjectType represents a Folder that contains KeyCredentialService Objects which may be accessed via the Server . It is defined in Table 123 . Table 123 - KeyCredentialManagementFolderType Definition Attribute Value BrowseName
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.6.1 OverviewServer to access resources such as Brokers or Authorization Servers . The KeyCredentialConfiguration Folder is a well-known Object that appears in the AddressSpace of any Server which supports KeyCredential management
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesKeyCredentialConfigurationFolderType This ObjectType is the TypeDefinition for an Folder Object that contains the KeyCredentialConfiguration Objects which may be accessed via the Server . Table 133 - KeyCredentialConfigurationFolderType Definition Attribute Value BrowseName
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.2 PublishSubscribeTypeprovides the PubSub capablitiy information. The PubSubCapabilitiesType ObjectType is defined in 9.1.12 . The DataSetClasses Folder allows a Server to expose DataSetClasses supported. These DataSetClasses can be used to create PublishedDataSets ... Folder would also be used by standard information models to include standardized DataSetClasses into their namespace. The DataSetClasses Folder references a list of Variables where the Value of a Variable
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.2.2.1 SafetyACSet ObjectSafetyACSet Object [RQ6.1] Each Server shall have a singleton Folder called SafetyACSet with a fixed NodeID in the Namespace of this document. Because all SafetyProviders and SafetyConsumers on this Server ... SafetyACSet definition Attribute Value BrowseName SafetyACSet References NodeClass BrowseName Comment OrganizedBy by the Objects Folder defined in OPC 10000-5. HasTypeDefinition ObjectType FolderType Entry point for all SafetyProviders and SafetyConsumers
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.3.2 FileSystem ObjectAddressSpace . HasComponent is used to reference a FileSystem from aggregating Objects like the Objects Folder or the Object representing a device
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationVariables which are components of the EnergyMeasurementType Objects organized in the "EnergyManagement" Folder Object . The SerializationScope is configured to exclude the constant metadata contained in the Properties belonging
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelDiagnostics 0:HasComponent Variable 3:CloseCallFailedCount 0:UInt32 0:BaseDataVariableType O FunctionalEntities provides a Folder for the FunctionalEntities that this AutomationComponent exposes. The Folder shall be restricted to hold only ... type derived from FunctionalEntityType or instances that implement the IFunctionalEntityType Interface . The Folder may be empty. FunctionalEntities can reference other FunctionalEntities , but FunctionalEntities that are directly referenced from this Folder
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelstring part of the BrowseName of a PublishedDataSet that is listed in the PublishedDataSets Folder tree of the PublishSubscribe Object (see OPC 10000-14 ). If PublisherCapabilities is referenced from
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelstring part of the BrowseName of a StandaloneSubscribedDataSet that is listed in the SubscribedDataSets Folder tree of the PublishSubscribe Object (see OPC 10000-14 ). If SubscriberCapabilities is referenced from
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.2 FxAssetType definitionProductInstanceUri, SerialNumber, or both shall be provided for Assets listed directly in the Assets Folder of the AutomationComponent . " RevisionCounter is an incremental counter indicating the number of times ... following definitions are associated with the IAssetExtensionsType interface (see 7.4 ). Connectors is a Folder used to group and list physical- or software-based connectors (instances of AssetConnectorType ) that
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.3 VerifyAsset methodAssetCompatibility and AssetIdentity are mandatory for top-level Assets (those directly in the Assets Folder in the AutomationComponent ). All optional Variables of AssetCompatibility are optional. ExpectedAdditionalVerificationVariables An array of NodeIdValuePair
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelinformation (for additional information, see 5.4 ). The ConfigurationDataFolderType is defined in 6.4.6 . The ConfigurationData Folder may also contain two FunctionalGroups ( Configuration or Tuning ) to further organise configuration information. The optional ... FunctionalEntity (see OPC 10000-100 Recommended FunctionalGroup BrowseNames ). The optional Capabilities is a FunctionalEntityCapabilitiesType Folder that describes the functionality provided by a FunctionalEntity (see 6.4.7 ). The optional PublisherCapabilities provide
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.4 InputsFolderTypereference to input Variables in this FunctionalEntity. The Variables shall be Organized in this Folder, or the Folder shall reference the Variable via subtypes of the HasChild Reference (HasProperty, HasComponent ... other subtypes ). The BrowseNames of Variables in this Folder shall be unique within this Folder ; the use of nested < InputGroup > can be used to help accomplish this. When
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.5 OutputsFolderTypereference to output Variables in this FunctionalEntity. The Variables shall be Organized in this Folder, or the Folder shall reference the Variable via subtypes of the HasChild Reference (HasProperty, HasComponent ... other subtypes ). The BrowseNames of Variables in this Folder shall be unique within this Folder ; the use of nested < OutputGroup > can be used to help accomplish this. When
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelFunctionalEntity Base < ConfigurationVariable > represents the optional configuration data. The Variables in this Folder shall be Organized in this Folder, or the Folder shall reference the Variables via subtypes ... HasChild Reference (HasProperty, HasComponent or other subtypes ). The BrowseNames of Variables in this Folder shall be unique within this Folder . All Variables in this folder shall be configuration data
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelFunctionalEntity Base The optional CommHealth aggregates the Status of all ConnectionEndpoints contained in the Folder . The aggregation rules are defined as follows: If at least one ConnectionEndpoint established at this
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelinformation in the Lock Object (i.e., the Lock LockingClient ) in either the ListToRestrict Folder or the ListToBlock Folder . The optional EstablishControl Method invokes the LockingServices in both the ListToBlock ... system-wide MaxInactiveLockTime , which a local MaxInactiveLockTime can overwrit e in each lock Folder . If the CleanupTimeout is different for each Connection , then a local MaxInactiveLockTime should be specified
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.5.4 ReleaseControl methodshall release the ControlGroup and issue a Call to the Lock Objects in each Folder for the ExitLock Method (see OPC 10000-100 ). It shall create the appropriate parameters
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.6.1 Overviewprovides information about which InputVariables and/or OutputVariables are exchanged. ConnectionEndpoints reside in the ConnectionEndpoints Folder of a FunctionalEntity . The ConnectionEndpointType is illustrated in Figure 27 . Figure 27 - ConnectionEndpointType illustration
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelDiagnostics 0:HasComponent Variable 4:CloseCallFailedCount 0:UInt32 0:BaseDataVariableType O ConnectionConfigurationSets provides a Folder for the ConnectionConfigurationSets (defined in 6.8 ) that are exposed by this ConnectionManager . It shall ... ConnectionConfigurationSetType, which provide the data required by a ConnectionManager to establish Connections . This Folder may also contain other Folders that can be used to organise the ConnectionConfigurationSets . The Folder
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelB.3.2.1 Extending an existing typeThis AutomationComponent instance would just reference the existing MyModelInstance from both the Assets Folder and the FunctionalEntities Folder . It is important to understand that this is just an illustration
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelReading the File allows the retrieval of the contents of the ConnectionConfigurationSets Folder of a ConnectionManager with one operation; writing it allows for adding, removing, or replacing ConnectionConfigurationSets . The ConnectionManagerConfigurationType
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.3.2.2 ElementAddF.3.3.2.2 ElementAdd The ConnectionConfigurationSetOperation ElementAdd adds the ConnectionConfigurationSet to the ConnectionConfigurationSets Folder tree in the Folder specified by the ConnectionConfigurationSetFolder . If Folders on the given path do not exist, they
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.4.2 Application and QoS engineeringinterfaces available to the UAFX Application , including VLAN interfaces, are contained in the NetworkInterfaces Folder defined in OPC 10000-22. The System Commissioner can finish the configuration of the Connections
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networkingpriority mapping configuration representation as defined in OPC 10000‑22 , including the PriorityMappingTableType , MappingTables Folder , and the UsesPriorityMappingTable ReferenceType (see 6.5.4 ); network interface representation as defined ... including the IetfBaseNetworkInterfaceType , the IIetfBaseNetworkInterfaceType and IIeeeBaseEthernetPortType Interfaces , and the NetworkInterfaces Folder (see ); C-VLAN configuration representation as defined in OPC 10000‑22 , including the IVlanIdType Interface and the HasLowerLayerInterface
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX NetworkingUAFX Application shall be represented as an instance of IetfBaseNetworkInterfaceType in the NetworkInterfaces Folder defined in OPC 10000‑22 . All VLAN interfaces attached to these physical network interfaces shall
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.2 UAFX BaseUAFX Preconfigured PublishedDataSet If preconfigured PublishedDataSets exist, the Server exposes the PublishSubscribe Object, the Folder hierarchy to all preconfigured PublishedDataSets , and all preconfigured PublishedDataSets . Server UAFX Preconfigured SubscribedDataSet If preconfigured ... SubscribedDataSets exist, the Server exposes the PublishSubscribe Object and the SubscribedDataSets Folder , any sub-folders of it, and all preconfigured SubscribedDataSets
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponentAutomationComponentType . Server UAFX AutomationComponent SupportsPersistence Includes the SupportsPersistence Variable in the ComponentCapabilities Folder, and that the value of SupportsPersistence is set to TRUE. Server UAFX AutomationComponent MaxConnections Includes the MaxConnections ... Variable in the ComponentCapabilities Folder a nd supports the claimed number of Connections . Note the actual maximum number of connections supported may be reduced during runtime due to resource restrictions
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.4 UAFX FxAssetProductInstanceUri Property of the IVendorNameplate Interface. IAssetExtensions Server UAFX IAssetExtensions Connectors Supports the Connectors Folder of the IAssetExtensions Interface with at least one instance of AssetConnectorType or subtype ... Folder . Server UAFX IAssetExtensions Diagnostics FunctionalGroup Supports the Diagnostics FunctionalGroup of the IAssetExtensions Interface. Server UAFX IAssetExtensions Diagnostics PowerOnUpTime Supports the PowerOnUpTime Variable of the IAssetExtensions Interface Diagnostics FunctionalGroup . Server
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.5 UAFX FunctionalEntityOperationalHealth Variable of the IFunctionalEntity Interface . Server UAFX IFunctionalEntity OperationalHealthAlarms Supports the OperationalHealthAlarms Folder of the IFunctionalEntity Interface . Server UAFX IFunctionalEntity Verify Supports the Verify Method of the IFunctionalEntity Interface
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerConnectionManagerCapabilitiesType FolderType . Server UAFX ConnectionManager Capabilities MaxConnectionConfigurationSets Includes the MaxConnectionConfigurationSets Variable in the Capabilities Folder and supports the behaviour related to it. Server UAFX ConnectionManager Capabilities MonitorsLocalConnectionEndpoints Includes the MonitorsLocalConnectionEndpoints ... Variable in the Capabilities Folder and supports the behaviour related to it. Server UAFX ConnectionManager Capabilities MonitorsAllConnectionEndpoints Includes the MonitorsAllConnectionEndpoints Variable in the Capabilities Folder and supports the behaviour related
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profilesfunctionality needed by a FunctionalEntity that is referenced directly by the AutomationComponentType FunctionalEntities Folder . Table 25 - UAFX top-level FunctionalEntity Facet Group Conformance Unit / Profile Title Optional UAFX FunctionalEntity Facet
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.2.16 UAFX Asset Facetfunctionality needed for an Asset that is referenced directly by the AutomationComponentType Assets Folder . Table 30 - UAFX Asset Facet Group Conformance Unit / Profile Title Optional UAFX IAssetRevision Facet DI IVendorNameplate
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profilespreconfigured PublishedDataSets exist, the Server exposes the PublishSubscribe Object, the Folder hierarchy to all preconfigured PublishedDataSets , and all preconfigured PublishedDataSets ." 9527 Feature Add LLDP facet to Controller Profile Created ... UAFX Controller 2024 Profile. 10334 Errata There is no ConformanceUnit for the optional DeviceHealthAlarms Folder of the FxAssetType Waiting for feedback from the DI WG about adding the DI-related
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.6 Requirementsspecific requirements. In order to provide access to the requirements, the concept of a Folder as defined in OPC 10000-5 is used. This specification just defines ... might provide the requirements using different access paths, but they should provide the Requirements Folder as well. This Folder might be organized into other Folders , so Clients shall expect that
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.7 CapabilitiesECLASS. In order to provide access to the capabilities, the concept of a Folder as defined in OPC 10000-5 is used. This specification just defines ... might provide the capabilities using different access paths, but they should provide the Capabilities Folder as well. This Folder might be organized into other Folders , so Clients shall expect that
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3controller programmer specific types are shown in Figure 14 . The Root and the Objects Folder are Nodes defined by OPC 10000-5 . The Objects Folder is the main entry point
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3point for UA client for the use cases Observation and Operation is the Objects Folder . One typical entry point is a list of Objects representing Ctrl Resources . Additional Folders Objects ... want to hide some of the components of a Ctrl Resources can create a Folder Object representing the Ctrl Resources and can use Organizes References to reference only the components
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsVariables of the FluidQuantitiesType only AbsolutePressure, DewPoint, RelativeHumidity, and Temperature are available. The optional Folder Components provides Folders for organizing Components connected to the Airnet . Usually, the Components are grouped ... Organizes ReferenceType. The concrete instance of a Component shall be instantiated in the Components Folder of the CASType instance. Figure 20 shows an example on how to instantiate the FunctionalGroup
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals7.3.1 OverviewOperationAboveHigh and OperationAboveHighHigh . The LimitCounters shall also be referenced as AddIn in the MachineryBuildingBlocks Folder to provide better access from a higher level. TriggerSettings represents the time period from