Search
31 result(s) for Read
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security ModelService calls until the Server has completed any user change. For Services like Read or Browse , the Server needs to ensure that any Service call that were issued under
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.58 AccessLevelExTyperepresent the atomicity of a Variable . In general Atomicity is expected of OPC UA read and write operations. These Fields are used by systems, in particular hard-realtime controllers, which ... TimestampWrite 6 See 8.57 . Reserved 7 See 8.57 . NonatomicRead 8 Indicates non-atomicity for Read access (0 means that atomicity is assured). NonatomicWrite 9 Indicates non-atomicity for Write access
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.3.1 DescriptionDescription The Session -less Service invocation is introduced for Services, such as Read , Write or Call , that do not require any caller specific state information. It is accessible through ... ensure consistency of namespace arrays between Client and Server . The UrisVersion is first read from the Server together with the NamespaceArray and ServerArray . This reduces the overhead per call
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesService failed. The additional parameters should include the details of the request. The Read and HistoryRead Services may generate audit entries and audit Events for failed Service invocations. These Services
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.6.2.4.5.4 Hotachieve load balancing; this means that Clients should issue Service requests such as Browse , Read , Write to the Server with the highest ServiceLevel. Subscription related activities will need
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.39 TimestampsToReturnenumeration that specifies the Timestamp Attributes to be transmitted for MonitoredItems or Nodes in Read and HistoryRead . The values of this parameter are defined in Table 180 . Table 180 - TimestampsToReturn
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.3.4 Arrayselement in the array shall be the type name. For example, the Read service takes an array of ReadValueIds. The XML schema would look like: <xs:complexType name
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsthis ConditionVariable . It shall be the same time that would be returned from the Read Service inside the DataValue structure for the ConditionVariable Value Attribute
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.3 OpenWithMasksOpenWithMasks The OpenWithMasks Method allows a Client to read only a portion of the TrustList. This Method can only be used to read the TrustList . After calling this Method ... Client calls Read one or more times to get the TrustList . If the Server is able to detect out of band changes to theTrustList before the Client calls the Close
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.1 PubSubConfigurationTypewith the Server . The FileType functionality is used instead of passing the PubSubConfiguration2DataType to read and write Methods to overcome potential limitations of communication buffers for OPC UA Service calls ... able to transfer large configurations. The Open Method shall not support modes other than Read (0x01), Write + EraseExisting (0x06) and Read + Write (0x03). When a Client opens the file
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubServer is organized in the Server Address Space . Services like Read , Write and Browse are available with a request/response pattern used by OPC UA Clients to access information provided
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.2.4 ReadRead Read is used to read a part of the file starting from the current file position. The file position is advanced by the number of bytes read. Signature Read ... InvalidState See OPC 10000-4 for a general description. File was not opened for read access. Table 4 specifies the AddressSpace representation for the Read Method . Table 4 - Read Method
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.4.3 GenerateFileForReadGenerateFileForRead GenerateFileForRead is used to start the read file transaction. A successful call of this Method creates a temporary FileType Object with the file content and returns the NodeId ... opened TransferFile . The fileHandle can be used to access the TransferFile Methods Read and Close . completionStateMachine If the creation of the file is completed asynchronous, the parameter returns the NodeId
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationClient / Server scenario, Clients can obtain the metadata initially by separate browse and read operations. Metadata changes can be notified using ModelChange and SemanticChange Events . When using Subscriptions , the Server ... affected DataSet . Considering possible application failure due to usage of outdated metadata, invoking the Read Service to obtain the Value of a merged compact representation not containing the associated metadata
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model13.1 Overviewinformation. Resolving Node information may require using View Services ( Browse , TranslateBrowsePathsToNodeIds ) and Attribute Services ( Read ). The details related to an application's configuration are provided in a Descriptor
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.2 Open Methodspecification does impose security restrictions. The Open Method shall not support modes other than Read (0x01) and Write + EraseExisting (0x06). The Client shall be authorised to modify the configuration
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition6.3.10.1 Definitionmode of Write + EraseExisting when Open is called. They may support mode of Read . Other modes are not allowed. When writing, if Close is called the file is discard
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.9 Variable LastScanDataClient. The delivery of scan results depends on the MonitoredItem settings or Read behaviour of the OPC UA Client . It is recommended that complex applications use scan Methods and Events
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.10 Variable LastScanTimestampClient. The delivery of scan results depends on the MonitoredItem settings or Read behaviour of the OPC UA Client . It is recommended that complex applications use scan Methods and Events
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.11 Variable LastScanAntennaClient. The delivery of scan results depends on the MonitoredItem settings or Read behaviour of the OPC UA Client . It is recommended that complex applications use scan Methods and Events
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.12 Variable LastScanRSSIClient. The delivery of scan results depends on the MonitoredItem settings or Read behaviour of the OPC UA Client . It is recommended that complex applications use scan Methods and Events
-
OPC-30020 – MDIS OPC UA Companion Specification5.2.3 SubscriptionsSubscriptions OPC UA supports Subscription and polling ( Read ) manners of obtaining data. The Subscription based manner of obtaining data should be used by default. Subscription , which is exception reporting, typically
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture7.3.1 PowerlinkAttributesPowerlinkVariableType ( 5.2.4 ). Table 27 - PowerlinkAttributes Values Value Bit Abbreviation Description Const 0 CONST Read access only, the value is not changing Read 1 R Read access Write 2 W Write ... Variables Attribute AccessLevel shall be contain the same value as the Field Read in the Variables Attribute PowerlinkAttributes . The Field CurrentWrite of the Variables Attribute AccessLevel shall be contain
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.7.2 Preset label CSPP elementreference source, and others are mapped to return values for the Services ( Read , Publish , Republish ) to be executed for the DataVariable s. Table 7‑3 shows the mapping specifications. Table ... Maps DATA item value of the element to the Attribute value. *1: For a Read Service , the results[] value corresponds to the DataValue DataType . For a Publish or Republish Service
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelServer shall set the StatusCode member of the DataValue structures returned by the Read Service and the Publish Service consistent with the content of the quality data when returning
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.4.2.1 GenerateFileForReadGenerateFileForRead This method is used to start the read file transaction. A successful call of this method creates a temporary FileType Object with the file content and returns the NodeId ... opened TransferFile . The FileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.6.2.1 GenerateFileForReadGenerateFileForRead This method is used to start the read file transaction. A successful call of this method creates a temporary FileType Object with the file content and returns the NodeId ... opened TransferFile . The fileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.7.2.6 Recipe transfervision system. Thus, transfer can be carried out using the standard Open , Read , Write , Close methods of the FileType object
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.12.2.1 GenerateFileForReadGenerateFileForRead This method is used to start the read file transaction. A successful call of this method creates a temporary FileType Object with the file content and returns the NodeId ... opened TransferFile . The FileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementB.1.7.2 Method-based recipe managementuses the NodeId and FileHandle of the created temporary file object to call its Read and Write methods to transfer the recipe content. The client uses the Close or CloseAndCommit
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementobject to open the pertaining file object for reading or writing. It uses the Read and Write methods of said component to transfer the data. It uses the Close method