OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.5.3 DataVariablesalso visible in the AddressSpace . In this case, this complex DataVariable could define HasComponent References from it to the individual temperature values that it is composed
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.5.2 ObjectType NodeClassabstract ObjectType , i.e. Objects of this type can exist. References HasComponent 0..* HasComponent References identify the DataVariables , the Methods , and Objects contained in the ObjectType . If and how the referenced ... Attribute indicates if the ObjectType is abstract or not. The ObjectType NodeClass uses the HasComponent References to define the DataVariables , Objects , and Methods for it. The HasProperty Reference is used
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelNodeClass . Organizes References can be used in any combination with HasChild References ( HasComponent , HasProperty , etc.; see 7.5 ) and do not prevent loops. Thus, they can be used to span multiple
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.2 Variable NodeClassDataVariable . Properties are not allowed to be the SourceNode of HasProperty References. HasComponent 0..* HasComponent References are used by complex DataVariables to identify their composed DataVariables . Properties are not allowed
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.3 Propertiestherefore they shall not be the SourceNode of any hierarchical References . This includes the HasComponent or HasProperty Reference , that is, Properties do not contain Properties and cannot expose their complex ... Reference . To distinguish them from DataVariables , they shall not be the TargetNode of any HasComponent Reference . Thus, a HasProperty Reference pointing to a Variable Node defines this Node
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.4 DataVariablespecified in Table 13 . DataVariables identify their Properties using HasProperty References . Complex DataVariables use HasComponent References to expose their component DataVariables . The Property NodeVersion indicates the version of the DataVariable ... also contain DataVariables . Therefore each DataVariable shall be the TargetNode of at least one HasComponent Reference coming from an Object , an ObjectType , a DataVariable or a VariableType . DataVariables shall
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClassClause 7 . A Method shall always be the TargetNode of at least one HasComponent Reference . The SourceNode of these HasComponent References shall be an Object or an ObjectType
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.4 OptionalPlaceholdermight have a Folder for DeviceParameters, and the DeviceParameters should be connected with a HasComponent Reference . However, the names of the DeviceParameters are specific to the instances. The example
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.5 MandatoryPlaceholdervalid as it uses the wrong ReferenceType to reference a DeviceParameter ( Organizes instead of HasComponent ) and Device C is not valid because it does not provide a DeviceParameter
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelB.2 Notationobject diagrams are used to display <<TypeExtension>> objects (e.g. HasComponent in Figure B.3 ). In object diagrams, OPC Attributes are represented as UML attributes without data types ... with the stereotype <<Attribute>>, like InverseName in the UML object HasComponent . They have values, like InverseName =ComponentOf for HasComponent . To keep the object diagrams simple
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelC.2.2 Simple notationexposed the same way as asymmetric ReferenceTypes except that an open arrow is used. HasComponent The notation provides a shortcut for HasComponent References shown on the left. The single hashed
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.2 ParametersObject or a super type of that ObjectType shall be the source of a HasComponent Reference (or subtype of HasComponent Reference ) to the Method specified in methodId . In case ... ObjectType , the ObjectType shall be the source of a HasComponent Reference (or subtype of HasComponent Reference ) to the Method specified in methodId. In this case the Method shall not have
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model4.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model11.21 HasAddInHasAddIn InverseName AddInOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the HasComponent ReferenceType defined in 11.7 . Conformance Units Address Space AddIn Reference
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsF.9 UAMethodMethodDeclarationId NodeId May be specified for Method Nodes that are a target of a HasComponent reference from a single Object Node . It is the NodeId of the UAMethod with
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.2 BranchBranch uses the Organizes References to reference child DA Branches and uses HasComponent References for DA Leafs (Items). It is acceptable for customized wrappers to use a sub-type
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsappear in the AddressSpace as an instance of some temperature transmitter Object with a HasComponent Reference to an instance of a LimitAlarmType . The availability of instances allows Data Access Clients
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The representation in the AddressSpace is specified in Table 5 This ReferenceType binds an AlarmSuppressionGroup
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionscase since Variables (and VariableTypes ) are not allowed to be the source of a HasComponent Reference to an Object. Figure 29 provides an example of this use case. Note that ... LvelMonitoring" Alarm . It is Server -specific whether and where they assign a HasComponent Reference . Figure 29 - Use of HasCondition in a VariableType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions9.2 AlarmMetricsTypeNodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseObjectType defined in 10000-5 . HasComponent Variable AlarmCount UInt32 BaseDataVariableType Mandatory HasComponent Variable StartTime UtcTime BaseDataVariableType Mandatory HasComponent Variable MaximumActiveState Duration ... BaseDataVariableType Mandatory HasComponent Variable MaximumUnAck Duration BaseDataVariableType Mandatory HasComponent Variable CurrentAlarmRate Double AlarmRateVariableType Mandatory HasComponent Variable MaximumAlarmRate Double AlarmRateVariableType Mandatory HasComponent Variable MaximumReAlarmCount UInt32 BaseDataVariableType Mandatory HasComponent Variable AverageAlarmRate Double
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.5.2 ProgramTransitionEventTypeBrowseName DataType TypeDefinition ModellingRule Subtype of the base TransitionEventType defined in OPC 10000-16 . HasComponent Variable IntermediateResult BaseDataType BaseDataVariableType Mandatory Conformance Units Program Basic TransitionNumber identifies the Program transition that ... ObjectType for the IntermediateResult specifies the collection of Variables using a set of HasComponent References
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.4 ServerConfigurationallows access to the Server's configuration and it is the target of an HasComponent reference from the Server Object defined in OPC 10000-5 . This Object and its immediate
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesObjects which may be accessed via the Server . It is the target of an HasComponent reference from the ServerConfiguration Object defined in 7.10.4 . It is defined in Table 135 . Table
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.7.3 AuthorizationServicesObjects which may be accessed via the Server . It is the target of an HasComponent reference from the ServerConfiguration Object defined in 7.10.4 . It is defined in Table 157 . Table
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates4.2.2.1 Generaltype definition. All Instances of the FolderType use the standard BrowseName of 'AggregateFunctions'. The HasComponent Reference is used to relate a ServerCapabilities Object and/or any HistoryServerCapabilitiesType Object to an AggregateFunction ... each HistoricalConfiguration Object belonging to a HistoricalDataNode may reference an AggregateFunction Object using the HasComponent Reference
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.3.10.5 ActionMethodsallowed to use the NodeId of a Method that is the target of a HasComponent Reference from the ObjectType of the Object . The namespace of the NodeId shall be added
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.6 HasPubSubConnectionconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be the PublishSubscribe Object defined ... BrowseName HasPubSubConnection InverseName PubSubConnectionOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.9 HasWriterGroupconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the PubSubConnectionType defined ... BrowseName HasWriterGroup InverseName IsWriterGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.10 HasReaderGroupconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the PubSubConnectionType defined ... BrowseName HasReaderGroup InverseName IsReaderGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.6 HasDataSetWriterconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the WriterGroupType defined ... BrowseName HasDataSetWriter InverseName IsWriterInGroup Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.12 HasDataSetReaderconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the ReaderGroupType defined ... BrowseName HasDataSetReader InverseName IsReaderInGroup Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.3 SubscribedDataSetMirrorTypeModel SubscribedDataSet Mirror An Object of this type shall reference a mirror Object with HasComponent where the name of the Object is based on the ParentNodeName . The Method CreateDataSetMirror ... mirror Object shall reference Variables for each DataSet field in the DataSetMetaData with HasComponent . The name, DataType , ValueRank and ArrayDimensions of the Variables shall match the settings for the corresponding
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.2.2.2 Safety ObjectType definitionsFigure 4 originating at SafetyProviderType or SafetyConsumerType and below shall be of ReferenceType HasComponent (and shall not be derived from ReferenceType HasComponent ) for Object References or ReferenceType HasProperty (and shall ... SafetyProviderType IsAbstract False References Node class BrowseName DataType TypeDefinition Modelling rule Subtype of SafetyObjectsType HasComponent Method ReadSafetyData Optional HasComponent Method ReadSafetyDiagnostics Optional HasComponent Object SafetyPDUs SafetyPDUsType Optional HasComponent Object Parameters
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.9 StateTypeshall be referenced from the ObjectType FiniteStateMachineType or one of its subtypes using a HasComponent Reference or a subtype of HasComponent and shall not have a ModellingRule as they
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.11 TransitionTypeshall be referenced from the ObjectType FiniteStateMachineType or one of its subtypes using a HasComponent Reference or a subtype of HasComponent and shall not have a ModellingRule as they
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.16 HasSubStateMachinesubtypes and the TargetNode shall be referenced from the same ObjectType , both using a HasComponent Reference or a subtype of HasComponent . The representation of the HasSubStateMachine ReferenceType in the AddressSpace
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.6.3 HasGuardconcrete ReferenceType and can be used directly. It is a subtype of HasComponent . The semantic of this ReferenceType is to point from a Transition to a Guard . The Guard indicates ... GuardOf Symmetric False IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the HasComponent ReferenceType defined in OPC 10000-5 Conformance Units Base Info Choice States
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.3.2 FileSystem ObjectBrowseName FileSystem . An OPC UA Server may have different FileSystem Objects in the AddressSpace . HasComponent is used to reference a FileSystem from aggregating Objects like the Objects Folder
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes4.6.1 Overviewother components, that the component requires in order to work. In contrast to the HasComponent ReferenceType , the related components are not considered to be subcomponents of the component. In contrast
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes4.12.2 Definitionconcrete ReferenceType and can be used directly. It is a subtype of HasComponent . The semantic of this ReferenceType is to relate a hardware component to its subcomponent, which is also ... BrowseName HasPhysicalComponent InverseName PhysicalComponentOf Symmetric FALSE IsAbstract FALSE References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 Conformance Units Base Info HasPhysicalComponent
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationReferenceType Properties . IncludeReferenceTypes contains HierarchicalReferences . This selects Variable1 , Object1 and Property3 . ExcludeReferenceTypes contains HasComponent . This removes Variable1 and Object1 from the selection. Therefore, only Property3 referenced by HasProperty is mapped
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationSerializationEntity . This SerializationEntity sets the ReferenceTypes to select all hierarchical References but no HasComponent References . As result, "Property1" and "Property1.1" are excluded by the "ObjectSerialization
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationRioChannelType Object is reached, since these Objects only have components referenced using the HasComponent ReferenceType . To include the components of the RioChannelType Objects into the SerializationScope , each Channel Object references ... SerializationEntity" Object which has the IncludeReferenceType array Property containing the HasComponent ReferenceType . The ConsiderSubElementSerializationProperties SerializationProperty of the "SerializationEntity" (see 6.3.6 ) referenced by the SerializationStartNode causes the settings
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName AutomationComponentConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentConfigurationType . The TargetNode of this ReferenceType ... InverseName AssetToVerifyOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentCapabilitiesType . The TargetNode of this ReferenceType ... InverseName CapabilityOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX AutomationComponent Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentConfigurationType . The TargetNode of this ReferenceType ... InverseName CharacteristicOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of ConnectionManagerCapabilitiesType . The TargetNode of this ReferenceType ... InverseName CMCapabilityOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName CommunicationFlowConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName ConnectionConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of ConnectionEndpointsFolderType . The TargetNode of this ReferenceType ... InverseName ConnectionEndpointOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a FunctionalEntity . The TargetNode of this ReferenceType shall ... InverseName ControlGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . It provides for the nesting of InputGroups . The SourceNode of this ReferenceType shall be an instance ... InverseName InputGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . It provides for the nesting of OutputGroups . The SourceNode of this ReferenceType shall be an instance ... InverseName OutputGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName ServerAddressOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelorganised within the InputData and OutputData . In addition, these Variables are referenced by HasComponent References from the SafetyPDUs Object of the SafetyProvider (see also OPC 10000-15 ). Safety
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.4.3 TransferServices Objectused as container for the TransferServices Methods and shall have the BrowseName Transfer . HasComponent is used to reference from a Device to its "TransferServices" Object . The TransferServiceType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesMethods and Properties and should have the BrowseName Lock . It shall be referenced using HasComponent or HasAddIn from the lock-owner Object (for example, a Device ). The LockingServicesType and each
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.5.3 AddLink Methodexternally managed resource by adding a Variable according to the input arguments with a HasComponent Reference to the Object the Method is called on. The server shall manage the added
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics13.3.3.1 Generalhierarchy. The ReferenceType is not further restricted, it is recommended to use the HasComponent ReferenceType . The hierarchy spanned should not contain loops, however, Clients shall not rely on this
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics13.4.3.1 Generalhierarchy. The ReferenceType is not further restricted, it is recommended to use the HasComponent ReferenceType . The hierarchy spanned should not contain loops, however, Clients shall not rely on this
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics14.1 Sub-Assetsassets shall be referenced from the asset with a hierarchical Reference , preferable 0: HasComponent or a subtype of it. Assets may reference their sub-assets directly, or have additional grouping
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation6.3.1 HasStatisticComponentconcrete ReferenceType and can be used directly. It is a subtype of 0: HasComponent . The semantic of this ReferenceType is to link Variables to an Object or ObjectType managing statistical ... Object or ObjectType implementing the IStatisticsType interface. References NodeClass BrowseName Comment Subtype of 0:HasComponent defined
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have