OPC UA for Plastics and Rubber Machinery - Peripheral Devices - Part 5: Moulds
8 MouldConfigurationType
8.1 MouldConfigurationType definition
The MouldConfigurationType provides information about the equipment of the mould and its current configuration. It is formally defined in Table 4.
Figure 2 - MouldConfiguration Overview
Table 4 - MouldConfigurationType Definition
Attribute
Value
BrowseName
MouldConfigurationType
IsAbstract
False
References
Node Class
BrowseName
DataType
TypeDefinition
Other
Subtype of 0:BaseObjectType defined in OPC 10000-5
0:HasProperty
Variable
PossibleConfigurations
0:String[]
0:PropertyType
M,RO
0:HasComponent
Variable
ActiveConfiguration
0:String
0:BaseDataVariableType
M,RO
0:HasComponent
Method
ChangeConfiguration
M
0:HasProperty
Variable
NumActiveCavities
0:UInt16
0:PropertyType
M,RO
0:HasProperty
Variable
Cavities
CavityStructureDataType[]
0:PropertyType
M,RO
0:HasComponent
Method
ChangeActiveCavities
M
0:HasComponent
Object
MouldConfigurationPicture
0:FileType
O
Conformance Units
OPC 40082-5 Basic
8.2 PossibleConfigurations
Some moulds are family moulds with different possible configurations e.g. by using inserts. The PropertyPossibleConfigurations lists the possible configurations. Each string shall be unique in the array.
8.3 ActiveConfiguration
This Property contains the active configuration of the mould. The value is one of the values given in the PropertyPossibleConfigurations.
8.4 ChangeConfiguration
Description:
Method to change the ActiveConfiguration Variable of the mould. Input Argument of the method is the desired configuration, which is given as the corresponding array index in the PossibleConfigurationsArray.
If the input index is out of range, the server should return the error code BadIndexRangeInvalid. In case of other errors, the server should return the error code BadInvalidArgument.
This Property represents the number of active cavities of the mould.
8.6 Cavities
This Structure gives information about the cavities of the mould. The CavityStructureDataType is defined in chapter 9.
8.7 ChangeActiveCavities
Description:
Method to change the CavityActive value of one single cavity in the Cavities Array of the mould. Input Argument of the method is the desired CavityActive value and the index of the cavity in the CavitiesArray.
The MouldConfigurationPicture Object provides a graphic file with information regarding the configuration of the mould. This can be used to display the picture on the HMI of the production machine.