11.3 SetOperationMode

Method to set the MachineryOperationMode. The input argument of this method is the desired State. Allowed values are the StateNumber values in the StateType defined the MachineryOperationModeStateMachineType Definition in OPC 40001-1: 0 (None), 1 (Maintenance), 2 (Setup), 3 (Processing).

Note: Not all States have to be supported by the mould. In this case, the server shall respond with the status code "Bad_NotSupported".

Signature

	SetOperationMode (
		[in] 0:UInt32	DesiredState);
Table 18 - SetOperationMode Method Arguments
ArgumentDescription
DesiredStateDesired MachineryOperationMode
Table 19 - SetOperationMode Method AddressSpace Definition
AttributeValue
BrowseNameSetOperationMode
ReferencesNode ClassBrowseName DataTypeTypeDefinitionModelling Rule
HasPropertyVariableInputArgumentsArgument[]PropertyTypeMandatory