11.3 SetOperationMode
Method to set the MachineryOperationMode. The input argument of this method is the desired State. Allowed values are the StateNumber values in the StateType defined the MachineryOperationModeStateMachineType Definition in OPC 40001-1: 0 (None), 1 (Maintenance), 2 (Setup), 3 (Processing).
Note: Not all States have to be supported by the mould. In this case, the server shall respond with the status code "Bad_NotSupported".
Signature
SetOperationMode (
[in] 0:UInt32 DesiredState);| Argument | Description |
| DesiredState | Desired MachineryOperationMode |
| Attribute | Value | ||||
| BrowseName | SetOperationMode | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Modelling Rule |
|---|---|---|---|---|---|
| HasProperty | Variable | InputArguments | Argument[] | PropertyType | Mandatory |