30.1 Conformance Units

This chapter defines the corresponding Conformance Unit for OPC 40082-5.

Table 45 - Conformance Units for OPC 40082-5
CategoryTitleDescription
ServerOPC 40082-5 BasicSupport of MouldDeviceType and all mandatory child elements giving information on the dosing system and its status. There is at least one instance of the MouldDeviceType in the Machines Object.
ServerOPC 40082-5 MaintenanceSupport of MaintenanceInformationType and all mandatory child elements giving information on the maintenance activities on the mould.
ServerOPC 40082-5 AlarmsThis Conformance Unit requires support of A & C Alarm Server Facet
ServerOPC 40082-5 UsersSupport of UserLoginType to enable automatic login of the machine user onto the mould controller.
ServerOPC 40082-5 TemperaturesSupport of TemperaturesType and MouldProcessValueType to monitor temperature process values of the mould.
ServerOPC 40082-5 TemperatureDifferencesSupport of TemperatureDifferencesType and MouldProcessValueType to monitor temperature difference process values of the mould.
ServerOPC 40082-5 PressuresSupport of PressuresType and MouldProcessValueType to monitor pressure process values of the mould.
ServerOPC 40082-5 PressureDifferencesSupport of PressureDifferencesType and MouldProcessValueType to monitor pressure difference process values of the mould.
ServerOPC 40082-5 FlowRatesSupport of FlowRatesType and MouldProcessValueType to monitor flow rate process values of the mould.
ServerOPC 40082-5 DistancesSupport of DistancesType and MouldProcessValueType to monitor distance process values of the mould.
ServerOPC 40082-5 ForcesSupport of ForcesType and MouldProcessValueType to monitor force process values of the mould.
ServerOPC 40082-5 AcousticValuesSupport of AcousticValuesType and MouldProcessValueType to monitor acoustic values of the mould.
ServerOPC 40082-5 DigitalInputsSupport of DigitalInputsType and DigitalValueType to monitor the digital inputs of the mould.
ServerOPC 40082-5 DigitalOutputsSupport of DigitalOutputsType and DigitalValueType to monitor the digital outputs of the mould.