30.1 Conformance Units
This chapter defines the corresponding Conformance Unit for OPC 40082-5.
| Category | Title | Description |
| Server | OPC 40082-5 Basic | Support of MouldDeviceType and all mandatory child elements giving information on the dosing system and its status. There is at least one instance of the MouldDeviceType in the Machines Object. |
| Server | OPC 40082-5 Maintenance | Support of MaintenanceInformationType and all mandatory child elements giving information on the maintenance activities on the mould. |
| Server | OPC 40082-5 Alarms | This Conformance Unit requires support of A & C Alarm Server Facet |
| Server | OPC 40082-5 Users | Support of UserLoginType to enable automatic login of the machine user onto the mould controller. |
| Server | OPC 40082-5 Temperatures | Support of TemperaturesType and MouldProcessValueType to monitor temperature process values of the mould. |
| Server | OPC 40082-5 TemperatureDifferences | Support of TemperatureDifferencesType and MouldProcessValueType to monitor temperature difference process values of the mould. |
| Server | OPC 40082-5 Pressures | Support of PressuresType and MouldProcessValueType to monitor pressure process values of the mould. |
| Server | OPC 40082-5 PressureDifferences | Support of PressureDifferencesType and MouldProcessValueType to monitor pressure difference process values of the mould. |
| Server | OPC 40082-5 FlowRates | Support of FlowRatesType and MouldProcessValueType to monitor flow rate process values of the mould. |
| Server | OPC 40082-5 Distances | Support of DistancesType and MouldProcessValueType to monitor distance process values of the mould. |
| Server | OPC 40082-5 Forces | Support of ForcesType and MouldProcessValueType to monitor force process values of the mould. |
| Server | OPC 40082-5 AcousticValues | Support of AcousticValuesType and MouldProcessValueType to monitor acoustic values of the mould. |
| Server | OPC 40082-5 DigitalInputs | Support of DigitalInputsType and DigitalValueType to monitor the digital inputs of the mould. |
| Server | OPC 40082-5 DigitalOutputs | Support of DigitalOutputsType and DigitalValueType to monitor the digital outputs of the mould. |