OPC-30141 – OPC UA for PROFIenergy3.2.2.1 Untitledcomprises the services allowing the switchover of a Standby Management Entity into an Energy Saving Mode , the change from one Energy Saving Mode into another and the transition back ... normal operational state. The switchover of a Standby Management Entity into an Energy Saving Mode is only possible if the Standby Management Entity is not in operation
-
OPC-30141 – OPC UA for PROFIenergy3.2.4.1 UntitledUntitled An Energy Saving Mode is a mode of operation in which energy consumption of a Standby Management Entity is lower than in normal operational state
-
OPC-30141 – OPC UA for PROFIenergy4.1.2 Standby ManagementStandby Management Entity supports more than one Energy Saving Mode (with different levels of energy consumption), transitions from one Energy Saving Mode into another might be possible. For the smooth ... Energy Saving Mode with switchback to normal operation. Devices might also support Sleep Mode WOL functionality allowing to completely switch off a device. If this Sleep Mode WOL functionality
-
OPC-30141 – OPC UA for PROFIenergyinto an Energy Saving Mode . The EnergyDevicePowerOffType Object provides access to the devices' Sleep Mode WOL if supported. Clients can initiate the transition into the Sleep Mode WOL by invoking ... SwitchOffWOL Method . Figure 7 - Structural organization of PE Energy Management related functionality Figure 8 shows the relationship between the PE Energy Management model and the other functional parts
-
OPC-30141 – OPC UA for PROFIenergyEnergy Saving Mode 4 Energy saving mode 5 Moving to ready to operate 6 Moving to Sleep mode WOL 7 Sleep mode WOL 8 Wake up WOL 9-15 'null ... operate Moving to Energy Saving Mode Energy saving mode Moving to ready to operate Moving to Sleep mode WOL Sleep mode WOL Wake up WOL The EnergySavingModes container Object contains
-
OPC-30141 – OPC UA for PROFIenergy8.1.1.1 StartPause MethodStartPause Method This Method starts the transition into an Energy Saving Mode . Signature StartPause ( [in] 0:Duration PauseTime [out] 0:Byte ModeID [out] 0:Duration CurrentTimeToDestination [out] 0:Duration RegularTimeToOperate ... Byte ReturnCode ); Argument Description PauseTime Requested pause time. ModeID ID of the destination Energy Saving Mode if successful, otherwise 0. CurrentTimeToDestination Time needed to reach the Energy Saving Mode
-
OPC-30141 – OPC UA for PROFIenergy8.1.1.2 SwitchToEnergySavingMode MethodSwitchToEnergySavingMode Method This Method initiates a switch to a certain Energy Saving Mode . Signature SwitchToEnergySavingMode ( [in] 0:Byte ModeID [out] 0:Byte EffectiveModeID [out] 0:Duration CurrentTimeToDestination [out] 0:Duration ... effectively chosen Energy Saving Mode if successful, otherwise ID of current mode. CurrentTimeToDestination Time needed to reach the destination Energy Saving Mode if successful, otherwise 0. RegularTimeToOperate Time needed
-
OPC-30141 – OPC UA for PROFIenergy8.1.1.3 EndPause MethodEndPause Method This Method ends the current Energy Saving Mode . Signature EndPause ( [out] 0:Duration CurrentTimeToOperate [out] 0:Byte ReturnCode ); Argument Description CurrentTimeToOperate Time needed to reach "Ready ... saving mode available. 0x52 No switch to requested energy-saving mode because of invalid mode ID. 0x53 No switch to Energy Saving Mode because of state operate. 0x54 Service
-
OPC-30141 – OPC UA for PROFIenergyindicated by the StateInformation Variable . The StateInformation Variable contains details for the actual Energy Saving Mode state
-
OPC-30141 – OPC UA for PROFIenergy8.1.4 EnergySavingModeTypeEnergy_Saving_Modes PE_Mode_ID TimeMinPause Get_Mode Time_min_Pause TimeToPause Get_Mode Time_to_Pause TimeMinLengthOfStay Get_Mode Time_min_length_of_stay TimeMaxLengthOfStay Get_Mode Time ... length_of_stay RegularTimeToOperate Get_Mode Regular_time_to_operate ModePowerConsumption Get_Mode Mode_Power_Consumption EnergyConsumptionToPause Get_Mode Energy_Consumption_to_pause EnergyConsumptionToOperate Get_Mode Energy_Consumption_to_operate
-
OPC-30141 – OPC UA for PROFIenergy8.3.1.1 SwitchOffWOL Method0xFE) if successful, otherwise 0. CurrentTimeToDestination Time needed to reach the Energy Saving Mode if successful, otherwise 0. RegularTimeToOperate Time needed to reach "Ready to operate" again
-
OPC-30141 – OPC UA for PROFIenergytransition state to an Energy Saving Mode . Table 39 - StandbyModeTransitionDataType Structure Name Type Description StandbyModeTransitionDataType Structure IDDestination 0:Byte Mode ID of destination Energy Saving Mode . CurrentTimeToDestination 0:Duration Time ... ongoing (dynamic) time value is not supported. Shall be 0 if destination Energy Saving Mode is reached. CurrentTimeToOperate 0:Duration Time needed to reach "Ready to operate
-
OPC-30141 – OPC UA for PROFIenergyEnergyStateInformationDataType Structure IDSource 0:Byte Mode ID of current Energy Saving Mode . IDDestination 0:Byte Mode ID of destination Energy Saving Mode . RegularTimeToOperate 0:Duration Time needed to reach ... Ready to operate" if the Energy Saving Mode is regularly terminated. Shall be 0 if IDSource is equal to 0xFF (The StandbyManagementStatus Variable has the value "Ready
-
OPC-30141 – OPC UA for PROFIenergyswitching on Energy Saving Mode s for unused energy consuming entities during breaks in a standard way. It also allows transitions between individual Energy Saving Mode s. PROFIenergy measurement functionality ... properties of the device with respect to energy functions, listing the supported Energy Saving Mode s, obtaining the properties of a specific Energy Saving Mode and retrieving detailed status information
-
OPC-30141 – OPC UA for PROFIenergyC.4 PE State Modeldisabled. The device will not execute commands requesting the transition into an energy-saving mode. PE_ready_to_operate 0xFF Standby Management is enabled and the device is able ... transition into an Energy Saving Mode . Moving to PE energy-saving-mode 0x1-0x1F, 0xFF 0x01-0x1F The device is in transition to one of the supported energy-saving modes
-
OPC-34100 – OPC UA for Energy Consumption ManagementManagement allows a device or parts of a device to switch into an Energy Saving Mode if not in operation or engaged ... Standby Management Entity supports more than one Energy Saving Mode (with different levels of energy consumption), transitions from one Energy Saving Mode into another might be possible (see Figure
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.1.1 OverviewEnergy Saving Mode 4 Energy saving mode 5 Moving to ready to operate 6 Moving to Sleep mode WOL 7 Sleep mode WOL 8 Wake up WOL 9-15 'null ... operate Moving to Energy Saving Mode Energy saving mode Moving to ready to operate Moving to Sleep mode WOL Sleep mode WOL Wake up WOL The EnergySavingModes container Object contains
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.1.2 StartPause MethodStartPause Method This Method starts the transition into an Energy Saving Mode . Signature StartPause ( [in] 0:Duration PauseTime [out] 0:Byte ModeID [out] 0:Duration CurrentTimeToDestination [out] 0:Duration RegularTimeToOperate ... Byte ReturnCode ); Argument Description PauseTime Requested pause time. ModeID ID of the destination Energy Saving Mode if successful, otherwise 0. CurrentTimeToDestination Time needed to reach the Energy Saving Mode
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.1.3 SwitchToEnergySavingMode MethodSwitchToEnergySavingMode Method This Method initiates a switch to a certain Energy Saving Mode . Signature SwitchToEnergySavingMode ( [in] 0:Byte ModeID [out] 0:Byte EffectiveModeID [out] 0:Duration CurrentTimeToDestination [out] 0:Duration ... effectively chosen Energy Saving Mode if successful, otherwise ID of current mode. CurrentTimeToDestination Time needed to reach the destination Energy Saving Mode if successful, otherwise 0. RegularTimeToOperate Time needed
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.1.4 EndPause MethodEndPause Method This Method ends the current Energy Saving Mode . Signature EndPause ( [out] 0:Duration CurrentTimeToOperate [out] 0:Byte ReturnCode ); Argument Description CurrentTimeToOperate Time needed to reach "Ready ... saving mode available. 0x52 No switch to requested energy-saving mode because of invalid mode ID. 0x53 No switch to Energy Saving Mode because of state operate. 0x54 Service
-
OPC-34100 – OPC UA for Energy Consumption ManagementEnergySavingModeStatusType The EnergySavingModeStatusType provides information about the current status of the Energy Saving Mode . Table 36 - EnergySavingModeStatusType Definition Attribute Value BrowseName EnergySavingModeStatusType IsAbstract False References Node Class BrowseName DataType TypeDefinition ... indicated by the StateInformation Variable . The StateInformation Variable contains details for the actual Energy Saving Mode state
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.4 EnergySavingModeTypeshall contain a unique name for the Energy Saving Mode . The ID Variable shall contain a unique mode ID for the Energy Saving Mode . The mode ID's 0x00, 0xF0 ... operate" to this Energy Saving Mode . Unit: [kWh]. The EnergyConsumptionToOperate Variable shall contain the energy consumption from this Energy Saving Mode to "Ready to operate". Unit
-
OPC-34100 – OPC UA for Energy Consumption Management7.3.1.2 SwitchOffWOL Method0xFE) if successful, otherwise 0. CurrentTimeToDestination Time needed to reach the Energy Saving Mode if successful, otherwise 0. RegularTimeToOperate Time needed to reach "Ready to operate" again
-
OPC-34100 – OPC UA for Energy Consumption Managementtransition state to an Energy Saving Mode . Table 41 - StandbyModeTransitionDataType Structure Name Type Description StandbyModeTransitionDataType Structure IDDestination 0:Byte Mode ID of destination Energy Saving Mode . CurrentTimeToDestination 0:Duration Time ... ongoing (dynamic) time value is not supported. Shall be 0 if destination Energy Saving Mode is reached. CurrentTimeToOperate 0:Duration Time needed to reach "Ready to operate
-
OPC-34100 – OPC UA for Energy Consumption ManagementEnergyStateInformationDataType Structure IDSource 0:Byte Mode ID of current Energy Saving Mode . IDDestination 0:Byte Mode ID of destination Energy Saving Mode . RegularTimeToOperate 0:Duration Time needed to reach ... Ready to operate" if the Energy Saving Mode is regularly terminated. Shall be 0 if IDSource is equal to 0xFF (the StandbyManagementStatus Variable has the value "Ready