31 result(s) for BaseEventType
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.2 BaseEventTypeBaseEventType This EventType is defined in OPC 10000-3 . Its representation in the AddressSpace is formally defined in Table 25 . Table 25 - BaseEventType definition Attribute Value BrowseName BaseEventType IsAbstract True ... specific to a Node the NodeId is set to null. Some subtypes of this BaseEventType may define additional rules for the SourceNode Property . SourceName provides a description of the source
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.7.2 EventTypesspecific EventType . A Server may support many types. This part defines the BaseEventType that all other EventTypes derive from. It is expected that other companion specifications will define additional EventTypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.15 GeneratesEventTargetNode of this ReferenceType shall be an ObjectType representing EventTypes , that is, the BaseEventType or one of its subtypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.16 AlwaysGeneratesEventTargetNode of this ReferenceType shall be an ObjectType representing EventTypes , that is, the BaseEventType or one of its subtypes
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model9.2 BaseEventTypeBaseEventType The BaseEventType defines all general characteristics of an Event . All other EventTypes derive from it. There is no other semantic associated with this type
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.4.5 SimpleAttributeOperandsubtypes. If the SimpleAttributeOperand is used in an EventFilter and the typeDefinitionId is BaseEventType the Server shall evaluate the browsePath without considering the typeDefinitionId . browsePath [] QualifiedName A relative path
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.22.3 EventFiltersame SimpleAttributeOperand . browsePath will apply to multiple EventTypes . If the Client specifies the BaseEventType in the SimpleAttributeOperand.typeDefinitionId then the Server shall evaluate the SimpleAttributeOperand.browsePath without considering the SimpleAttributeOperand.typeDefinitionId . Each InstanceDeclaration ... description of this result code. The typeId is not the NodeId for BaseEventType or a subtype of it. Bad_NodeIdUnknown See Table 179 for the description of this result code
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.3 AuditEventTypeBrowseName AuditEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable ActionTimeStamp ... Auditing History Services Auditing Write Auditing Method This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The BaseEventType Properties are used to describe the source
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.28 SystemEventTypeValue BrowseName SystemEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Status Underlying System Base Info System Status This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . There are no additional Properties defined for this EventType
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.31 BaseModelChangeEventTypeValue BrowseName BaseModelChangeEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Info Model Change This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . There are no additional Properties defined for this EventType . The SourceNode Property
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.33 SemanticChangeEventTypeValue BrowseName SemanticChangeEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable Changes ... PropertyType Mandatory Conformance Units Base Info SemanticChange This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.34 EventQueueOverflowEventTypeValue BrowseName EventQueueOverflowEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. Conformance Units Base ... Info EventQueueOverflow EventType This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall be assigned
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.35 ProgressEventTypeValue BrowseName ProgressEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 6.4.2 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable Context ... Mandatory Conformance Units Base Info Progress Events This EventType inherits all Properties of the BaseEventType . Their semantic is defined in 6.4.2 . The SourceNode Property for Events of this type shall
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model8.2.6 ObjectTypesindustry, such as the ServerType defined in 6.3.1 . This Object also indirectly references the BaseEventType defined in 6.4.2 , which is the base type of all EventTypes . Thereby
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions4.2 Conditionsspecific ConditionType . The ConditionType and derived types are sub-types of the BaseEventType (see 10000-3 and 10000-5 ). This part defines types that are common across many industries
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.1 Generalbase Event model by defining various Event Types based on the BaseEventType . All of the Event Types defined in this document can be further extended from domain to Server specific
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.1 Generalintroduces the concept of states differentiating it from the base Event model. Unlike the BaseEventType , Conditions are not transient. The ConditionType is further extended into Dialog and AcknowledgeableConditionType , each
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypeValue BrowseName ConditionType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the BaseEventType defined in 10000-5 HasSubtype ObjectType DialogConditionType Defined in Clause 5.6.2 HasSubtype ObjectType AcknowledgeableConditionType Defined ... column indicates that no ModellingRule applies. The ConditionType inherits all Properties of the BaseEventType . Their semantic is defined in 10000-5 . SourceNode Property identifies the ConditionSource . See 5.12 for more
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.2.3 Event categoriesServer are represented in the UA Server as ObjectTypes which are subtypes of BaseEventType . The BrowseName and DisplayName of the ObjectType Node for Simple and Tracking Event Types are constructed ... Wrapper does not know these semantics then Simple Event Types are subtypes of BaseEventType , Tracking Event Types are subtypes of AuditEventType and Condition Event Types are subtypes of the AlarmType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.3.3 Event Type mappingType mapping Since all Alarms and Conditions Event s belong to a subtype of BaseEventType , the A&E COM UA Proxy maps the subtype as received from
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsD.3.4 Event category mappingconsist of the set of Event types defined in the hierarchy of subtypes of BaseEventType excluding AuditEventType and ConditionType and their respective subtypes. Figure D.3 - Example mapping of UA Event
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsfollowing items are present for all A&E event types szSource UA BaseEventType Property: SourceName ftTime UA BaseEventType Property: Time szMessage UA BaseEventType Property: Message dwEventType See Clause D.3.3 ... dwEventCategory See Clause D.3.4 dwSeverity UA BaseEventType Property: Severity dwNumEventAttrs Calculated within A&E COM UA Proxy pEventAttributes Constructed within A&E COM UA Proxy The following items
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessshall include at least the event fields Time , SourceName and Severity of the BaseEventType Type defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.13.3 PubSubCommunicationFailureEventTypeThis EventType inherits all Properties of the PubSubStatusEventType . The Message Event field inherited from BaseEventType has a localized description of the error. The Error Property has the StatusCode associated with
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.6 FiniteStateMachineTypeEvent . The Event is indicated by a HasEffect Reference to a subtype of BaseEventType . The StateMachineType shall have GeneratesEvent References to the targets of a HasEffect Reference for each
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.17 TransitionEventTypeTransitionEventType The TransitionEventType is a subtype of the BaseEventType . It can be used to generate an Event identifying that a Transition of a StateMachine was triggered. It is formally defined ... BrowseName TransitionEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the base BaseEventType defined in OPC 10000-5 HasComponent Variable Transition LocalizedText TransitionVariableType Mandatory HasComponent Variable FromState LocalizedText
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Modelinclusive and corresponds to the range provided in the OPC UA BaseEventType (see OPC 10000-3 ). Additional details for mapping of the severity defined for OPC BaseEvents to LogRecords ... Describes the specific type of Event. It corresponds to the EventType field defined in BaseEventType . If AdditionalData is provided then an EventType should be provided. True SourceNode 0:NodeId Identifies
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject ModelEvent to have a ConditionClassId or SubConditionClassId of LogEntryConditionClass . The following describes fields in BaseEventType that are mapped to a LogRecord : Time - the time associated with this event. EventType ... defined in BaseEventType in OPC 10000-5 SourceNode - identifies the Node that the Event originated from, as defined in BaseEventType in OPC 10000-5 . For LogObject Events , this node
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.3 BaseLogEventTypeBaseLogEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:BaseEventType defined in OPC 10000-5 . 0:HasProperty Variable ErrorCode 0:StatusCode 0:PropertyType O 0:HasProperty ... specific Node is related to the LogRecord . The ConditionClassId and ConditionClassName in BaseEventType are made mandatory in this EventType . The ConditionClassId shall be set to LogEntryConditionClassType . TraceContext is an instance
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionConfigurationSetEventType is formally defined in Table 112 . It is a subtype of the BaseEventType defined in OPC 10000-5 . This new type does not add any additional information ... BaseEventType besides the semantics that an Event was generated by the ConnectionConfigurationSetStateMachineType . Table 112 - ConnectionConfigurationSetEventType Attribute Value BrowseName 4:ConnectionConfigurationSetEventType IsAbstract True References NodeClass BrowseName DataType TypeDefinition Other Subtype
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicsmaintenance activity should be put into the Message field defined for the BaseEventType in OPC 10000-5 . The maintenance activity starts, when the MaintenanceState changes to Execution, and finished, when