Search
19 result(s) for 0:Structure
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 77 - RioPaDigitalInputConfigDataType Structure Name Type Description RioPaDigitalInputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. InversionEnabled 0:Boolean ... Value BrowseName RioPaDigitalInputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 79 - RioFaDigitalInputConfigDataType Structure Name Type Description RioFaDigitalInputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. SupplyVoltageCheckEnabled 0:Boolean ... Value BrowseName RioFaDigitalInputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 81 - RioPaDigitalOutputConfigDataType Structure Name Type Description RioPaDigitalOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. InversionEnabled 0:Boolean ... Value BrowseName RioPaDigitalOutputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 83 - RioFaDigitalOutputConfigDataType Structure Name Type Description RioFaDigitalOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. SupplyVoltageCheckEnabled 0:Boolean ... Value BrowseName RioFaDigitalOutputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel according to RIO PA . Table 85 - RioPaAnalogInputConfigDataType Structure Name Type Description RioPaAnalogInputConfigDataType structure Damping 0:Float Damping time (T63) in seconds applied to an analog signal in the Function ... Value BrowseName RioPaAnalogInputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaAnalogInputConfigDataType Structure Name Type Description RioFaAnalogInputConfigDataType structure Damping time (T63) in seconds applied to an analog signal in the Function Block . Damping 0:Float Damping time (T63) in seconds applied ... Value BrowseName RioFaAnalogInputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 89 - RioPaAnalogOutputConfigDataType Structure Name Type Description RioPaAnalogOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. SubstitutePolicy RioSubstitutePolicyEnumeration Substitute ... Value BrowseName RioPaAnalogOutputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IOTable 91 - RioFaAnalogOutputConfigDataType Structure Name Type Description RioFaAnalogOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled 0:Boolean True if wire check is active for the channel, otherwise False. SupplyVoltageCheckEnabled 0:Boolean ... Value BrowseName RioFaAnalogOutputConfigDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.1 RioPaDigitalValueDataTypeaccording to RIOforPA. Table 93 - RioPaDigitalValueDataType Structure Name Type Description RioPaDigitalValueDataType structure Subtype of 0:Structure defined in OPC 10000-3 . Value 0:Boolean Current value. Qualifier 0:Byte Current ... Value BrowseName RioPaDigitalValueDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.2 RioFaDigitalValueDataTypeaccording to RIOforFA. Table 95 - RioFaDigitalValueDataType Structure Name Type Description RioFaDigitalValueDataType structure Subtype of 0:Structure defined in OPC 10000-3 . Value 0:Boolean Current value. Qualifier 0:Boolean Current ... Value BrowseName RioFaDigitalValueDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.6 RioPaAnalogValueDataTypeaccording to RIOforPA. Table 103 - RioPaAnalogValueDataType Structure Name Type Description RioPaAnalogValueDataType structure Subtype of 0:Structure defined in OPC 10000-3 . Value RioAnalogDataType Current value. Qualifier 0:Byte Current status ... Value BrowseName RioPaAnalogValueDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure defined in OPC 10000-3 . Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IO10.2.7 RioFaAnalogValueDataTypeaccording to RIOforFA. Table 105 - RioFaAnalogValueDataType Structure Name Type Description RioFaAnalogValueDataType structure Subtype of 0:Structure defined in OPC 10000-3 . Value RioAnalogDataType Current value. Qualifier 0:Boolean Current status ... Value BrowseName RioFaAnalogValueDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure defined in OPC 10000-3 . Conformance Units PNRIO Channel Objects
-
OPC-30142 – OPC UA for PROFINET Remote IO10.3 RioBitFieldDataTypecontaining 32 bits. Table 111 - RioBitFieldDataType Structure Name Type Description RioBitFieldDataType structure Subtype of 0:Structure defined in OPC 10000-3 . BitData 0:UInt32 32-bit unsigned representing 32 bits ... Attribute Value BrowseName RioBitFieldDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of 0:Structure defined in OPC 10000-3 . Conformance Units PNRIO Channel Objects The bit numbers
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>10.1 LogEntryDataTypeLogEntryDataType Table 38 - LogEntryDataType Structure Name Type Description LogEntryDataType structure FaultSituationNumber 0:Byte Identification of fault situation. 0 means current fault situation. Values greater than 0 identify historic fault situations ... Value BrowseName LogEntryDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure type defined in OPC 10000-3 Conformance Units PNENC Logbook Readable
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model10.1 GsdGenIoTimeDataTypeTable 30 - GsdGenIoTimeDataType Structure Name Type Description Allow Subtypes GsdGenIoTimeDataType structure Subtype of 0:Structure defined in OPC 10000-3 . NumberOfMilliseconds 0:UInt32 Used for TimeOfDay: Number of milliseconds since ... Value BrowseName GsdGenIoTimeDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure defined in OPC 10000-3 . Conformance Units PNGSDGM BMP Access
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelTable 32 - GsdGenIoTimeStampDataType Structure Name Type Description Allow Subtypes GsdGenIoTimeStampDataType structure Subtype of 0:Structure defined in OPC 10000-3 . Status 0:UInt16 Time source, see [ PN PROTOCOL ... Value BrowseName GsdGenIoTimeStampDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of the 0:Structure defined in OPC 10000-3 . Conformance Units PNGSDGM IO Data PNGSDGM Data Objects
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsTable 115 . Table 115 - PhysicalAddressDataType Structure Name Type Description PhysicalAddressDataType structure Subtype of 0:Structure defined in OPC 10000-5. Street 0:LocalizedText Street name where the manufacturer is located
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsstructure is defined in Table 114 . Table 114 - FilterClassDataType Structure Name Type Description FilterClassDataType structure Filter class according to ISO 8573-1. A FilterClassEnum Class for particles B FilterClassEnum Class ... Attribute Value BrowseName FilterClassDataType IsAbstract False References NodeClass BrowseName DataType TypeDefinition Other Subtype of 0:Structure defined
-
OPC-40540 – OPC UA for Additive Manufacturing10.1 RunInfoDataTypeTable 23 . Table 23 - RunInfoDataType Structure Name Type Description Optional RunInfoDataType structure Subtype of 0:Structure defined in OPC 10000-5 CurrentLayer 0:UInt32 Counter that increases after each completed ... BrowseName RunInfoDataType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:Structure defined in OPC 10000-5 Conformance Units AdditiveManufacturing Job Management - Run Information