The PumpType is the representation of a Pump and organizes its properties in FunctionalGroups. It is illustrated in Figure 9 and formally defined in Table 9.
Figure 9 – Illustration of PumpType
Attribute |
Value |
||||
BrowseName |
PumpType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:TopologyElementType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
2:Configuration |
|
ConfigurationGroupType |
O |
0:HasComponent |
Object |
Documentation |
|
DocumentationType |
O |
0:HasComponent |
Object |
Events |
|
SupervisionType |
O |
0:HasComponent |
Object |
2:Identification |
|
PumpIdentificationType |
M |
0:HasComponent |
Object |
2:Maintenance |
|
MaintenanceGroupType |
O |
0:HasComponent |
Object |
2:Operational |
|
OperationalGroupType |
O |
0:HasComponent |
Object |
Ports |
|
PortsGroupType |
O |
The PumpType ObjectType is a concrete type and shall be used directly.
To comply with the Finding all Machines in a Server use case of OPC UA for Machinery, all Pumps shall be added to the 3:Machines Object defined in (OPC 40001-1).
The optional FunctionalGroup 2:Configuration provides collections of Nodes for manufacturer data about the Pump and user data about the Pump’s process environment, such as maximum operating temperature and minimum flow rate.
The optional FunctionalGroup Documentation provides Nodes that are used to store Pump documentation, such as an operating manual and an overview drawing.
The optional FunctionalGroup Events provides collections of Nodes that are used for Pump monitoring, such as failure states, alarms, and conditions.
The mandatory FunctionalGroup 2:Identification provides Nodes for Pump identification, such as the manufacturer, serial number, and article number.
The optional FunctionalGroup 2:Maintenance provides collections of Nodes used for Pump maintenance, such as mean time between failures and installation date.
The optional FunctionalGroup 2:Operational provides collections of Nodes for process data that is used during normal Pump operation, such as measurements, signals, and actuation.
The optional FunctionalGroup Ports provides Nodes for the representation of Pump Ports, such as the inlet, outlet, and drive port.
The InstanceDeclarations of the PumpType have additional Attributes defined in Table 10.
Table 10 – PumpType Attribute values for child Nodes
BrowsePath |
Description Attribute |
2:Configuration |
Static design, system requirements, and implementation data of the pump. |
Documentation |
Static documentation files of a pump. |
Events |
States, alarms, and conditions of a pump. |
2:Identification |
Identification information of a pump. |
2:Maintenance |
Maintenance data of a pump. |
2:Operational |
Process data for control, actuation, signals, and measurements of the pump. |
Ports |
Connection points of the pump. |
The IPumpVendorNameplateType provides the capabilities to globally uniquely identify a Pump. It is a subtype of the 3:IMachineVendorNameplateType and extends it by Pump specific Objects and Variables.
The IPumpVendorNameplateType is formally defined in Table 11.
Table 11 – IPumpVendorNameplateType Definition
Attribute |
Value |
||||
BrowseName |
IPumpVendorNameplateType |
||||
IsAbstract |
True |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 3:IMachineVendorNameplateType defined in OPC 40001-1, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasProperty |
Variable |
ArticleNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
CountryOfOrigin |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
DayOfConstruction |
0:Int32 |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
FabricationNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
GTINCode |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
NationalStockNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
OrderProductCode |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
PhysicalAddress |
PhysicalAddressDataType |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
Supplier |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
TypeOfProduct |
0:String |
0:PropertyType |
O, RO |
The InstanceDeclarations of the IPumpVendorNameplateType have additional Attributes defined in Table 12. The Variables and the associated Descriptions are based on the IEC Common Data Dictionary (CDD). The basis for this are the IEC 61360-4, 61987 and 62683 standards.
Table 12 – IPumpVendorNameplateType Attribute values for child Nodes
BrowsePath |
Description Attribute |
ArticleNumber |
Alphanumeric character sequence identifying a manufactured, non-configurable product. |
CountryOfOrigin |
Country in which the product is manufactured. |
DayOfConstruction |
The optional DayOfConstrucition provides the day of the month in which the manufacturing process of the machine has been completed. It shall be a number and never change during the life-cycle of a machine. |
FabricationNumber |
Alphanumeric character sequence assigned to a fabricated product, which allows the date, time and circumstances of fabrication to be traced. |
GTINCode |
Bar code number that identifies the device based on the Global Trade Item Number system. |
NationalStockNumber |
13-digit numeric code, identifying all 'standardized material items of supply' as recognized by the United States Department of Defense. |
OrderProductCode |
Unique combination of numbers and letters used to order the device. |
PhysicalAddress |
Physical address of the manufacturer. |
Supplier |
Name of the supplier or vendor of a device. |
TypeOfProduct |
Characterization of the device based on its usage, operation principle, and its fabricated form. |
The MarkingsType provides a placeholder Object for safety instructions for the safe use of an asset, such as CE marking, temperature and pressure resistance, electrostatic charge, high voltage, radioactivity or explosive protection.
Table 13 – MarkingsType Definition
Attribute |
Value |
||||
BrowseName |
MarkingsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 0:FolderType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
<Marking> |
|
0:FileType |
OP |
The InstanceDeclarations of the MarkingsType have additional Attributes defined in Table 14.
Table 14 – MarkingsType Attribute values for child Nodes
BrowsePath |
Description Attribute |
<Marking> |
Placeholder for saving markings. |
The PumpIdentificationType provides Nodes for a globally unique identification, vendor defined information, and user-specific information of a Pump. It is illustrated in Figure 10 and formally defined in Table 15.
Figure 10 – Illustration of PumpIdentificationType
Table 15 – PumpIdentificationType Definition
Attribute |
Value |
||||
BrowseName |
PumpIdentificationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 3:MachineIdentificationType defined in OPC 40001-1, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasInterface |
ObjectType |
IPumpVendorNameplateType |
|
|
|
0:HasComponent |
Object |
Markings |
|
MarkingsType |
O |
|
|
|
|
|
|
Applied from IPumpVendorNameplateType |
|||||
0:HasProperty |
Variable |
ArticleNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
CountryOfOrigin |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
DayOfConstruction |
0:Int32 |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
FabricationNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
GTINCode |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
NationalStockNumber |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
OrderProductCode |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
PhysicalAddress |
PhysicalAddressDataType |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
Supplier |
0:String |
0:PropertyType |
O, RO |
0:HasProperty |
Variable |
TypeOfProduct |
0:String |
0:PropertyType |
O, RO |
|
|
|
|
|
|
The following nodes override nodes added by the 3:MachineIdentificationType |
|||||
0:HasProperty |
Variable |
2:DeviceClass |
0:String |
0:PropertyType |
M, RO |
The optional Property 2:DeviceClass of the 3:MachineIdentificationType is overridden. The ModellingRule is changed to Mandatory and the Value Attribute is set to “Pump”.
The InstanceDeclarations of the PumpIdentificationType have additional Attributes defined in Table 16.
Table 16 – PumpIdentificationType Attribute values for child Nodes
BrowsePath |
Value |
Description Attribute |
Markings |
|
Safety instructions for safe use, e.g. temperature and pressure resistance, electrostatic charge, high voltage, radioactivity, explosive protection. |
2:DeviceClass |
“Pump” |
Domain or for what purpose this item is used. |
The DocumentationType provides various FileType Objects for documents and Variables for links to documents that are used for maintenance operations. It is formally defined in Table 17.
Table 17 – DocumentationType Definition
Attribute |
Value |
||||
BrowseName |
DocumentationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Arrangements |
- |
0:FileType |
O |
0:HasComponent |
Variable |
ArrangementsLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
Certificates |
- |
0:FileType |
O |
0:HasComponent |
Variable |
CertificatesLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
CircuitDiagram |
- |
0:FileType |
O |
0:HasComponent |
Variable |
CircuitDiagramLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
ComponentsList |
- |
0:FileType |
O |
0:HasComponent |
Variable |
ComponentsListLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
Detail |
- |
0:FileType |
O |
0:HasComponent |
Variable |
DetailLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
DuringMaintenanceServicesRendered |
- |
0:FileType |
O |
0:HasComponent |
Variable |
DuringMaintenanceServicesRenderedLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
ImplementationDescription |
- |
0:FileType |
O |
0:HasComponent |
Variable |
ImplementationDescriptionLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
Layout |
- |
0:FileType |
O |
0:HasComponent |
Variable |
LayoutLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
Location |
- |
0:FileType |
O |
0:HasComponent |
Variable |
LocationLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
LogicDiagram |
- |
0:FileType |
O |
0:HasComponent |
Variable |
LogicDiagramLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
LubricationMap |
- |
0:FileType |
O |
0:HasComponent |
Variable |
LubricationMapLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
MaintenanceManual |
- |
0:FileType |
O |
0:HasComponent |
Variable |
MaintenanceManualLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
OperationManual |
- |
0:FileType |
O |
0:HasComponent |
Variable |
OperationManualLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
PersonnelRecording |
- |
0:FileType |
O |
0:HasComponent |
Variable |
PersonnelRecordingLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
PipeAndInstrumentDiagram |
- |
0:FileType |
O |
0:HasComponent |
Variable |
PipeAndInstrumentDiagramLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
ScopeOfWork |
- |
0:FileType |
O |
0:HasComponent |
Variable |
ScopeOfWorkLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
SingleLineDiagram |
- |
0:FileType |
O |
0:HasComponent |
Variable |
SingleLineDiagramLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
SparePartReference |
- |
0:FileType |
O |
0:HasComponent |
Variable |
SparePartReferenceLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
Staff |
- |
0:FileType |
O |
0:HasComponent |
Variable |
StaffLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
TechnicalData |
- |
0:FileType |
O |
0:HasComponent |
Variable |
TechnicalDataLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
TestProgramReport |
- |
0:FileType |
O |
0:HasComponent |
Variable |
TestProgramReportLink |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
UnitMaintenanceReport |
- |
0:FileType |
O |
0:HasComponent |
Variable |
UnitMaintenanceReportLink |
0:String |
0:DataItemType |
O, RO |
The InstanceDeclarations of the DocumentationType have additional Attributes defined in Table 18. The Variables and the associated Descriptions are based on the standard DIN EN 13460.
Table 18 – DocumentationType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Arrangements |
Drawing showing replacement components layout for an item. |
ArrangementsLink |
Drawing showing replacement components layout for an item. |
Certificates |
Specific safety and statutory regulations certificates for items (lifting equipment, steam boilers, pressure vessels,...). |
CertificatesLink |
Specific safety and statutory regulations certificates for items (lifting equipment, steam boilers, pressure vessels,...). |
CircuitDiagram |
Overall feeder and control circuits diagram. |
CircuitDiagramLink |
Overall feeder and control circuits diagram. |
ComponentsList |
Comprehensive list of items which constitute part of another one. |
ComponentsListLink |
Comprehensive list of items which constitute part of another one. |
Detail |
Drawing with part list to ensure dismantling, repair and assembly of items. |
DetailLink |
Drawing with part list to ensure dismantling, repair and assembly of items. |
DuringMaintenanceServicesRendered |
Final and/or interim report on services provided |
DuringMaintenanceServicesRenderedLink |
Final and/or interim report on services provided |
ImplementationDescription |
Explanation of the work carried out |
ImplementationDescriptionLink |
Explanation of the work carried out |
Layout |
Drawing showing all areas of a particular plant. |
LayoutLink |
Drawing showing all areas of a particular plant. |
Location |
Drawing showing the position of all field items within the considered area. |
LocationLink |
Drawing showing the position of all field items within the considered area. |
LogicDiagram |
System control diagram to clarify the overall system logic. |
LogicDiagramLink |
System control diagram to clarify the overall system logic. |
LubricationMap |
Drawing showing position of each item lubrication point, with lubrication data and specifications. |
LubricationMapLink |
Drawing showing position of each item lubrication point, with lubrication data and specifications. |
MaintenanceManual |
Technical instructions intended to preserve an item in, or restore it to, a state in which it can perform a required function. |
MaintenanceManualLink |
Technical instructions intended to preserve an item in, or restore it to, a state in which it can perform a required function. |
OperationManual |
Technical instructions to reach a proper item function performance according to its technical specifications and safety conditions. |
OperationManualLink |
Technical instructions to reach a proper item function performance according to its technical specifications and safety conditions. |
PersonnelRecording |
List of all activities (work order) performed by a technician. This list includes a predefined time period |
PersonnelRecordingLink |
List of all activities (work order) performed by a technician. This list includes a predefined time period |
PipeAndInstrumentDiagram |
Overall fluid conduction (air, steam, oil, fuel ...), and control diagram. |
PipeAndInstrumentDiagramLink |
Overall fluid conduction (air, steam, oil, fuel ...), and control diagram. |
ScopeOfWork |
The hours worked in the execution of the work order. The type of hours worked should be indicated: normal, in shifts, at night, overtime, etc. |
ScopeOfWorkLink |
The hours worked in the execution of the work order. The type of hours worked should be indicated: normal, in shifts, at night, overtime, etc. |
SingleLineDiagram |
Overall power distribution diagram (electrical, pneumatic, hydraulic). This kind of diagram includes switchboard circuits. |
SingleLineDiagramLink |
Overall power distribution diagram (electrical, pneumatic, hydraulic). This kind of diagram includes switchboard circuits. |
SparePartReference |
List of all spare parts used within the scope of the work order |
SparePartReferenceLink |
List of all spare parts used within the scope of the work order |
Staff |
List of all maintenance workers involved in the execution of the work order |
StaffLink |
List of all maintenance workers involved in the execution of the work order |
TechnicalData |
Manufacturer`s specification of the item. |
TechnicalDataLink |
Manufacturer`s specification of the item. |
TestProgramReport |
Commissioning report which demonstrates that an item is in compliance with specifications. |
TestProgramReportLink |
Commissioning report which demonstrates that an item is in compliance with specifications. |
UnitMaintenanceReport |
List of work orders for a particular unit. The list is created for a specified period of time |
UnitMaintenanceReportLink |
List of work orders for a particular unit. The list is created for a specified period of time |
The MaintenanceGroupType provides FunctionalGroups for general maintenance and specific maintenance strategies, such as condition based maintenance, preventive maintenance, and breakdown maintenance. It is illustrated in Figure 11 and formally defined in Table 19.
Figure 11 – Illustration of MaintenanceGroupType
Table 19 – MaintenanceGroupType Definition
Attribute |
Value |
||||
BrowseName |
MaintenanceGroupType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
BreakdownMaintenance |
|
BreakdownMaintenanceType |
O |
0:HasComponent |
Object |
ConditionBasedMaintenance |
|
ConditionBasedMaintenanceType |
O |
0:HasComponent |
Object |
GeneralMaintenance |
|
GeneralMaintenanceType |
O |
0:HasComponent |
Object |
PreventiveMaintenance |
|
PreventiveMaintenanceType |
O |
The InstanceDeclarations of the MaintenanceGroupType have additional Attributes defined in Table 20.
Table 20 – MaintenanceGroupType Attribute values for child Nodes
BrowsePath |
Description Attribute |
BreakdownMaintenance |
Properties for breakdown maintenance. |
ConditionBasedMaintenance |
Properties for condition based maintenance. |
GeneralMaintenance |
General maintenance properties. |
PreventiveMaintenance |
Properties for preventive maintenance. |
The GeneralMaintenanceType provides Variables that are used for general maintenance applications and is formally defined in Table 21.
Table 21 – GeneralMaintenanceType Definition
Attribute |
Value |
||||
BrowseName |
GeneralMaintenanceType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ActiveMaintenanceTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DownTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ExternalDisabledTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
FailureRate |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
IdleTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaintenanceLevel |
MaintenanceLevelEnum |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
MaintenanceTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MeanOperatingTimeBetweenFailures |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MeanRepairTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MeanTimeToRestauration |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Obsolescence |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OperatingTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OperatingTimeBetweenFailures |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OperatingTimeToFailure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
RepairTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
StandbyTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
StateOfTheItem |
StateOfTheItemEnum |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
TimeBetweenFailures |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
TimeToRestoration |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
UpTime |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the GeneralMaintenanceType have additional Attributes defined in Table 22. The Variables and the associated Descriptions are based on the standards ISO 13372 and DIN EN 13306.
Table 22 – GeneralMaintenanceType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
ActiveMaintenanceTime |
|
Part of the maintenance time when active maintenance is carried out on an item. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
DownTime |
|
Measured time interval throughout which an item is in a down state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
ExternalDisabledTime |
|
Measured time interval throughout which an item is in an external disabled state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
FailureRate |
|
Number of failures within a population divided by the number of life units used by that population |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
IdleTime |
|
Measured time interval throughout which an item is in an idle state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MaintenanceLevel |
|
Maintenance task categorization by complexity |
||
MaintenanceTime |
|
Time interval when maintenance is carried out on an item including technical, logistic and internal administrative delays |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MeanOperatingTimeBetweenFailures |
|
Average of the operating times between failures |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MeanRepairTime |
|
Average of the repair times |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MeanTimeToRestauration |
|
Average of the time to restauration |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
Obsolescence |
|
Inability of an item to be maintained due to the unavailability on the market of the necessary resources at acceptable technical and/or economic conditions. A "True" status means that the pump is obsolete and a "False" status means that the pump is not obsolete. |
||
OperatingTimeBetweenFailures |
|
Operating time between consecutive failures |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
OperatingTime |
|
Measured time interval throughout which an item is in operating state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
OperatingTimeToFailure |
|
Operating time accumulated from the first use, or from restoration, until failure |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
RepairTime |
|
Part of corrective maintenance time when repair is carried out on an item. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
StandbyTime |
|
Measured time interval throughout which an item is in a standby state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
StateOfTheItem |
|
Current state of the item |
||
TimeBetweenFailures |
|
Duration between consecutive failures |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
TimeToRestoration |
|
Time interval, from the instant of failure, until restoration |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
UpTime |
|
Measured time interval throughout which an item is in an up state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
The ConditionBasedMaintenanceType provides Variables that are used for condition based maintenance and is formally defined in Table 23.
Table 23 – ConditionBasedMaintenanceType Definition
Attribute |
Value |
||||
BrowseName |
ConditionBasedMaintenanceType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
Availability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Durability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ExpectedReliability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
InstantaneousAvailability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
IntrinsicMaintainability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
IntrinsicReliability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Maintainability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OperationalReliability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ProductionBasedAvailability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Reliability |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
TimeBasedAvailability |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the ConditionBasedMaintenanceType have additional Attributes defined in Table 24. The Variables and the associated Descriptions are based on the standards ISO 13372 and DIN EN 13306.
Table 24 – ConditionBasedMaintenanceType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
Availability |
|
Probability that a machine will, when used under specified conditions, operate satisfactorily and effectively |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
Durability |
|
Actual reliability of an item considering operating modes, operating conditions and possible preventive maintenance actions carried out |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
ExpectedReliability |
|
Reliability of an item determined by design and manufacture under expected conditions of operation and maintenance |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
InstantaneousAvailability |
|
Probability that an item is in a state to perform as required at a given instant, under given conditions, assuming that the necessary external resources are provided |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
IntrinsicMaintainability |
|
Maintainability of an item determined by the design under expected conditions of maintenance and logistic support |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
IntrinsicReliability |
|
Reliability of an item determined by design and manufacture under expected conditions of operation assuming that no preventive maintenance task is carried out, excepting routine maintenance |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
Maintainability |
|
Ability of a machine or part of a system to be retained in, or restored to, a state in which it can perform the required function(s) |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
OperationalReliability |
|
Actual reliability of an item considering operating modes, operating conditions and possible preventive maintenance actions carried out |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
ProductionBasedAvailability |
|
Ratio of actual production to required production, or any other reference level, over a specified period of time |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
Reliability |
|
Probability that a machine will perform its required functions without failure for a specified time period when used under specified conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
TimeBasedAvailability |
|
During a given period of time, percentage of the time during which an item was able to perform when required |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
The PreventiveMaintenanceType provides Variables that are used for preventive maintenance and is formally defined in Table 25.
Table 25 – PreventiveMaintenanceType Definition
Attribute |
Value |
||||
BrowseName |
PreventiveMaintenanceType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ActivePreventiveMaintenanceTime |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
InstallationDate |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
LastInspectionDate |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
LastServicingDate |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
NextInspectionDate |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
NextServicingDate |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
PreventiveMaintenanceTime |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the PreventiveMaintenanceType have additional Attributes defined in Table 26. The Variables and the associated Descriptions are based on the standards DIN EN 13306 and VDMA 24223-1.
Table 26 – PreventiveMaintenanceType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
ActivePreventiveMaintenanceTime |
|
This attribute indicates the date of installation or commissioning of the device. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
InstallationDate |
|
This attribute identifies the date when the device was last inspected. |
||
LastInspectionDate |
|
This attribute identifies the date when the device is scheduled for the next inspection. |
||
LastServicingDate |
|
This attribute identifies the date when the device is scheduled for the next servicing. |
||
NextInspectionDate |
|
This attribute identifies the date when the device was last serviced. |
||
NextServicingDate |
|
Part of maintenance time when preventive maintenance is carried out on an item, including technical, logistic and internal administrative delays |
||
PreventiveMaintenanceTime |
|
Part of the active maintenance time taken to perform a preventive maintenance |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
The BreakdownMaintenanceType provides Variables that are used for breakdown maintenance and is formally defined in Table 27.
Table 27 – BreakdownMaintenanceType Definition
Attribute |
Value |
||||
BrowseName |
BreakdownMaintenanceType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
CorrectiveMaintenanceTime |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Criticality |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Failure |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
NumberOfFailures |
0:Int32 |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Severity |
0:String |
0:DataItemType |
O, RO |
The InstanceDeclarations of the PreventiveMaintenanceType have additional Attributes defined in Table 28. The Variables and the associated Descriptions are based on the standards ISO 13372 and DIN EN 13306.
Table 28 – BreakdownMaintenanceType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
CorrectiveMaintenanceTime |
|
Part of the maintenance time when active corrective maintenance is carried out on an item, including technical, logistic and internal administrative delays |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
Criticality |
|
Index of the severity of an effect combined with the probability of expected frequency of its occurrence |
||
Failure |
|
Termination of the ability of an item to perform a required function. A "True" status means that the pump has a failure and a "False" status means that the pump has no failure. |
||
NumberOfFailures |
|
Number of failures of an object |
||
Severity |
|
Extent of loss, damage or harm caused by a fault or failure |
The SupervisionType provides collections of Variables used for Pump monitoring. It is illustrated in Figure 12 and formally defined in Table 29.
Figure 12 – Illustration of SupervisionType
Table 29 – SupervisionType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
SupervisionAuxiliaryDevice |
|
SupervisionAuxiliaryDeviceType |
O |
0:HasComponent |
Object |
SupervisionElectronics |
|
SupervisionElectronicsType |
O |
0:HasComponent |
Object |
SupervisionHardware |
|
SupervisionHardwareType |
O |
0:HasComponent |
Object |
SupervisionMechanics |
|
SupervisionMechanicsType |
O |
0:HasComponent |
Object |
SupervisionProcessFluid |
|
SupervisionProcessFluidType |
O |
0:HasComponent |
Object |
SupervisionPumpOperation |
|
SupervisionPumpOperationType |
O |
0:HasComponent |
Object |
SupervisionSoftware |
|
SupervisionSoftwareType |
O |
The InstanceDeclarations of the SupervisionType have additional Attributes defined in Table 30.
Table 30 – SupervisionType Attribute values for child Nodes
BrowsePath |
Description Attribute |
SupervisionAuxiliaryDevice |
Supervision auxiliary device specifies information for monitoring an additional device. |
SupervisionElectronics |
Supervision Electrics specifies information for monitoring the electronics. |
SupervisionHardware |
Supervision hardware specifies supervising information related to device hardware. |
SupervisionMechanics |
Supervision mechanics specifies supervising information related to device mechanics. |
SupervisionProcessFluid |
Supervision process fluid specifies information for monitoring the fluid of a pump. |
SupervisionPumpOperation |
Supervision pump operation specifies information for monitoring the pump operation. |
SupervisionSoftware |
Supervision software specifies supervising information related to device software. |
The SupervisionMechanicsType provides Variables used for monitoring the Pump mechanics. It is illustrated in Figure 13 and formally defined in Table 31. For the generation of events, the SupervisionMechanicsType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Figure 13 – Illustration of SupervisionMechanicsType
Table 31 – SupervisionMechanicsType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionMechanicsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
AxialBearingAbrasion |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AxialBearingFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AxialBearingOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
BearingFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
BrakeChopper |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
BrakeOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ExcessVibration |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
GapWear |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MechanicalFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Misalignment |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
RadialBearingAbrasion |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
RadialBearingFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
RadialBearingOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
RotorBlocked |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
RotorStationRubbing |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Unbalance |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionMechanicsType have additional Attributes defined in Table 32. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 32 – SupervisionMechanicsType Attribute values for child Nodes
BrowsePath |
Description Attribute |
AxialBearingAbrasion |
This attribute indicates an unacceptable abrasion of the axial bearing. |
AxialBearingFault |
This attribute indicates a failure of the axial bearing. |
AxialBearingOverheat |
This attribute indicates an overheating of the axial bearing. |
BearingFault |
This attribute indicates a generic bearing failure. |
BrakeChopper |
This attribute indicates a problem of the brake chopper. |
BrakeOverheat |
This attribute indicates an overheating of a brake. |
ExcessVibration |
This attribute indicates unacceptable high mechanical vibration. |
GapWear |
This attribute indicates a mechanical wear at gap. |
MechanicalFault |
This attribute indicates a generic mechanical fault. |
Misalignment |
This attribute indicates a misalignment. |
RadialBearingAbrasion |
This attribute indicates an unacceptable abrasion of the radial bearing. |
RadialBearingFault |
This attribute indicates a failure of the radial bearing. |
RadialBearingOverheat |
This attribute indicates an overheating of the radial bearing. |
RotorBlocked |
This attribute indicates a blocked rotor. |
RotorStationRubbing |
This attribute indicates the rubbing of stator and rotor. |
Unbalance |
This attribute indicates an unbalance. |
The SupervisionHardwareType provides Variables used for monitoring the Pump hardware. It is formally defined in Table 33. For the generation of events, the SupervisionHardwareType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 33 – SupervisionHardwareType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionHardwareType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
Communication |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ComputingCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ControlCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
DCLinkSupply |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Eprom |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
HardwareFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
IONA |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MeasureCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MicroProcessor |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
NetworkNA |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
PowerSupply |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Ram |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionHardwareType have additional Attributes defined in Table 34. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 34 – SupervisionHardwareType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Communication |
This attribute indicates a communication failure. |
ComputingCircuit |
This attribute indicates a failure in the computing elements of device hardware. |
ControlCircuit |
This attribute indicates a failure in the control elements of device hardware. |
DCLinkSupply |
This attribute indicates a failure in the dc power supply of device hardware. |
Eprom |
This attribute indicates a failure of an eprom. |
HardwareFault |
This attribute indicates a failure of device hardware. |
IONA |
This attribute indicates a disconnection between processing unit and device. |
MeasureCircuit |
This attribute indicates a failure in the measurement elements of device hardware. |
MicroProcessor |
This attribute indicates a failure of the micro processor. |
NetworkNA |
This attribute indicates a disconnection of the device. |
PowerSupply |
This attribute indicates a failure in the power supply of device hardware. |
Ram |
This attribute indicates a ram failure. |
The SupervisionSoftwareType provides Variables used for monitoring the Pump software. It is formally defined in Table 35. For the generation of events, the SupervisionSoftwareType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 35 – SupervisionSoftwareType Definition
Attribute |
Value |
|||||
BrowseName |
SupervisionSoftwareType |
|||||
IsAbstract |
False |
|||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
||||||
0:HasComponent |
Variable |
Application |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Communication |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Control |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Memory |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
OS |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Parameter |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
SoftwareFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
SoftwareReset |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionSoftwareType have additional Attributes defined in Table 36. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 36 – SupervisionSoftwareType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Application |
This attribute indicates a failure in application software. |
Communication |
This attribute indicates a failure in communication software. |
Control |
This attribute indicates a failure in control software. |
Memory |
This attribute indicates a memory resource problem. |
OS |
This attribute indicates a failure of operation system software. |
Parameter |
This attribute indicates a parameter problem. |
SoftwareFault |
This attribute indicates a failure of device software. |
SoftwareReset |
This attribute indicates a software reset. |
The SupervisionProcessFluidType provides Variables used for monitoring the Pump process fluid. It is formally defined in Table 37. For the generation of events, the SupervisionProcessFluidType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 37 – SupervisionProcessFluidType Definition
Attribute |
Value |
|||||
BrowseName |
SupervisionProcessFluidType |
|||||
IsAbstract |
False |
|||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
||||||
0:HasComponent |
Variable |
Blockage |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Cavitation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Condensation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Dry |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Flow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Gas |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Liquid |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Pressure |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
ProcessFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Solid |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Stall |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Temperature |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Viscosity |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
|||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionProcessFluidType have additional Attributes defined in Table 38. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 38 – SupervisionProcessFluidType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Blockage |
This attribute indicates a closed valve operation. |
Cavitation |
This attribute indicates cavitation of the pump liquid. |
Condensation |
This attribute indicates abnormal condensation in flow medium. |
Dry |
This attribute indicates a dry running. |
Flow |
This attribute indicates an abnormal flow of the pump fluid. |
Gas |
This attribute indicates a significant amount of gas in the pump liquid. |
Liquid |
This attribute indicates a significant amount of liquid in the flow medium. |
Pressure |
This attribute indicates an abnormal pressure of the pump fluid. |
ProcessFault |
This attribute indicates a generic process problem. |
Solid |
This attribute indicates an significant amount of solid in the pump fluid. |
Stall |
This attribute indicates a stall of the pump liquid. |
Temperature |
This attribute indicates an abnormal temperature of the pump fluid. |
Viscosity |
This attribute indicates an abnormal viscosity of the pump liquid. |
The SupervisionPumpOperationType provides Variables used for monitoring the Pump operation. It is formally defined in Table 39. For the generation of events, the SupervisionPumpOperationType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 39 – SupervisionPumpOperationType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionPumpOperationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
AccessoryLiquidFlow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AccessoryLiquidHigh |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AccessoryLiquidLow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AccessoryLiquidOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AccessoryLiquidPressure |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AmbientTemperature |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CaseOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ControllerOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ConverterOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CoolantFlow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CoolantHigh |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CoolantLow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CoolantOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Deceleration |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
DirtyImpeller |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
DriveOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
GeneratorOperation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Leakage |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Lubricant |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MaximumNumberStarts |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MaximumOperationTime |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MaximumStartsAtTime |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MotorHumidity |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MotorOverheat |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OperationFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OverLoad |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OverSpeed |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
PartialLoad |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Synchronisation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TemperatureFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TimeOut |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TMSFailure |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TorqueLimit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TurbineOperation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
UnderSpeed |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
VelocityLimit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WearReserveExhausted |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionPumpOperationType have additional Attributes defined in Table 40. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 40 – SupervisionPumpOperationType Attribute values for child Nodes
BrowsePath |
Description Attribute |
AccessoryLiquidFlow |
This attribute indicates a problem with the accessory liquid flow, e.g. the buffer fluid flow or operating fluid flow. |
AccessoryLiquidHigh |
This attribute indicates a high limited accessory liquid, e.g. the buffer fluid or operating fluid. |
AccessoryLiquidLow |
This attribute indicates a low limited accessory liquid, e.g. the buffer fluid or operating fluid. |
AccessoryLiquidOverheat |
This attribute indicates an overheating of the accessory liquid, e.g. the buffer fluid or operating fluid. |
AccessoryLiquidPressure |
This attribute indicates an abnormal pressure of the accessory liquid, e.g. the buffer fluid pressure or operating fluid pressure. |
AmbientTemperature |
This attribute indicates an abnormal ambient temperature. |
CaseOverheat |
This attribute indicates an overheating of the case. |
ControllerOverheat |
This attribute indicates an overheating of a controller. |
ConverterOverheat |
This property indicates an overheating of a converter. |
CoolantFlow |
This attribute indicates a problem with the coolant flow. |
CoolantHigh |
This attribute indicates that the coolant is high limited. |
CoolantLow |
This attribute indicates that the coolant is low limited. |
CoolantOverheat |
This attribute indicates an overheating of the coolant liquid. |
Deceleration |
This attribute indicates a deceleration of a pump. |
DirtyImpeller |
This attribute indicates a dirty impeller. |
DriveOverheat |
This attribute indicates an overheating of a drive. |
GeneratorOperation |
This attribute indicates that the pump is working as a generator (in flow). |
Leakage |
This attribute indicates a leakage problem, e.g. leakage of the mechanical seal. |
Lubricant |
This attribute indicates a problem with the lubricant. |
MaximumNumberStarts |
This attribute indicates that the maximum number of pump start cycles is exceeded. |
MaximumOperationTime |
This attribute indicates that the maximum time of pump operation is exceeded. |
MaximumStartsAtTime |
This attribute indicates that the maximum number of pump start cycles per timespan is exceeded. |
MotorHumidity |
This attribute indicates unacceptable humidity in the motor. |
MotorOverheat |
This attribute indicates an overheating of a motor. |
OperationFault |
This attribute indicates a generic operation problem of a pump. |
OverLoad |
This attribute indicates an over load. |
OverSpeed |
This attribute indicates that the pump operates over normal speed. |
PartialLoad |
This attribute indicates a partial load. |
Synchronisation |
This attribute indicates a synchronization problem of a pump. |
TemperatureFault |
This attribute indicates a generic temperature problem of a pump. |
TimeOut |
This attribute indicates a start up time out. |
TMSFailure |
This attribute indicates a failure of the temperature management system. |
TorqueLimit |
This attribute indicates a limitation problem of a pump. |
TurbineOperation |
This attribute indicates that the pump is working as a turbine (reverse flow). |
UnderSpeed |
This attribute indicates that the pump operates under normal speed. |
VelocityLimit |
This attribute indicates a limitation problem of a pump. |
WearReserveExhausted |
This attribute indicates that the wear reserve of the pump is exhausted. |
The SupervisionAuxiliaryDeviceType provides Variables used for monitoring the Pump auxiliary devices. It is formally defined in Table 41. For the generation of events, the SupervisionAuxiliaryDeviceType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 41 – SupervisionAuxiliaryDeviceType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionAuxiliaryDeviceType |
||||
IsAbstract |
false |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ActuatorElement |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AmbientTemperature |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryDeviceFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryMediumAbsence |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryMediumInsufficiency |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryPowerPole |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryPowerRange |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CommunicationError |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Corrosion |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Deviation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ElectromagneticInterference |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ElectronicFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
EnergySupply |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
EvaluationElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ExciterError |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Fouling |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
HumidityElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Installation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Interruption |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
LineLength |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MaterialElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MeasuredMaterialElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MechanicalDamage |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OperatingConditions |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Other |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Overloading |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ParameterSetting |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Peripheral |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ProcessInfluence |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SensorElement |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
StartUp |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TemperatureShock |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Vibration |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WearReserveOperation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WearReserveWear |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionAuxiliaryDeviceType have additional Attributes defined in Table 42. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 42 – SupervisionAuxiliaryDeviceType Attribute values for child Nodes
BrowsePath |
Description Attribute |
ActuatorElement |
This property indicates a fault in an actuator element. |
AmbientTemperature |
This property indicates an abnormal ambient temperature. |
AuxiliaryDeviceFault |
This property indicates a generic failure of an auxiliary device. |
AuxiliaryMediumAbsence |
This property indicates an absence of or wrong auxiliary medium. |
AuxiliaryMediumInsufficiency |
This property indicates an insufficiency of auxiliary medium. |
AuxiliaryPowerPole |
This property indicates an auxiliary power supply wrongly poled. |
AuxiliaryPowerRange |
This property indicates an off-spec of the auxiliary power range. |
CommunicationError |
This property indicates a communication error. |
Corrosion |
This property indicates corrosion/abrasion in parts in contact with medium. |
Deviation |
This property indicates an inadmissible deviation from measurement. |
ElectromagneticInterference |
This property indicates an abnormal electromagnetic interference. |
ElectronicFault |
This property indicates a fault in the device electronics. |
EnergySupply |
This property indicates an error in internal energy supply. |
EvaluationElectronics |
This property indicates an error in evaluation electronics. |
ExciterError |
This property indicates an error in the exciter of the sensor element. |
Fouling |
This property indicates a fouling on sensor element. |
HumidityElectronics |
This property indicates an abnormal amount of humidity in electronics area. |
Installation |
This property indicates an installation fault. |
Interruption |
This property indicates an interruption of signal path or short circuit. |
LineLength |
This property indicates that the maximum line length is exceeded. |
MaterialElectronics |
This property indicates a foreign material in electronics area. |
MeasuredMaterialElectronics |
This property indicates measured material in electronics area. |
MechanicalDamage |
This property indicates a mechanical damage. |
OperatingConditions |
This property indicates a fault due to non-compliance with specified operating conditions. |
Other |
This property indicates other faults. |
Overloading |
This property indicates an overloading. |
ParameterSetting |
This property indicates a parameter setting error. |
Peripheral |
This property indicates an error in peripherals. |
ProcessInfluence |
This property indicates a fault due to process influence. |
SensorElement |
This property indicates a fault in a sensor element. |
StartUp |
This property indicate an installation fault or fault during start-up. |
TemperatureShock |
This property indicates an excessive temperature shock. |
Vibration |
This property indicates an excessive vibration or impact load. |
WearReserveOperation |
This property indicates that the wear reserve is used up by operation. |
WearReserveWear |
This property indicates that the wear reserve is used up by wear. |
The SupervisionElectronicsType provides Variables used for monitoring the Pump electronics. It is formally defined in Table 43. For the generation of events, the SupervisionElectronicsType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 43 – SupervisionElectronicsType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionElectronicsType |
||||
IsAbstract |
false |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ArmatureCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CurrentInsideDevice |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ElectricalFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
FieldCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
InstallationFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
InsulationResistance |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
PhaseFailure |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ShortCircuit |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ShortToEarth |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyCurrent |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyCurrentHigh |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyCurrentLow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyFrequency |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyFrequencyHigh |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyFrequencyLow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyVoltage |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyVoltageHigh |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SupplyVoltageLow |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
VoltageInsideDevice |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WindingTemperature |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionElectronicsType have additional Attributes defined in Table 44. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 44 – SupervisionElectronicsType Attribute values for child Nodes
BrowsePath |
Description Attribute |
ArmatureCircuit |
This property indicates a failure in armature circuit. |
CurrentInsideDevice |
This property indicates unacceptable current inside the device. |
ElectricalFault |
This property indicates a generic electrical fault. |
FieldCircuit |
This property indicates a failure in field circuit. |
InstallationFault |
This property indicates an unacceptable electrical installation, e.g. mixed up phases. |
InsulationResistance |
This property indicates an unacceptable low winding resistance. |
PhaseFailure |
This property indicates a phase failure. |
ShortCircuit |
This property indicates a short circuit. |
ShortToEarth |
This property indicates a short to earth. |
SupplyCurrent |
This property indicates a failure of supply current. |
SupplyCurrentHigh |
This property indicates too high supply current. |
SupplyCurrentLow |
This property indicates too low supply current. |
SupplyFrequency |
This property indicates unacceptable supply frequency. |
SupplyFrequencyHigh |
This property indicates too high supply frequency. |
SupplyFrequencyLow |
This property indicates too low supply frequency. |
SupplyVoltage |
This property indicates a failure of supply voltage. |
SupplyVoltageHigh |
This property indicates too high supply voltage. |
SupplyVoltageLow |
This property indicates too low supply voltage. |
VoltageInsideDevice |
This property indicates unacceptable voltage inside the device. |
WindingTemperature |
This property indicates an unacceptable winding temperature. |
The ConfigurationGroupType provides FunctionalGroups for static manufacturer data about the Pump and user data about the Pump’s process environment. General information on this use case can be found in chapter 5.2. It is formally defined in Table 45.
Table 45 – ConfigurationGroupType Definition
Attribute |
Value |
||||
BrowseName |
ConfigurationGroupType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Design |
|
DesignType |
O |
0:HasComponent |
Object |
Implementation |
|
ImplementationType |
O |
0:HasComponent |
Object |
SystemRequirements |
|
SystemRequirementsType |
O |
The InstanceDeclarations of the ConfigurationGroupType have additional Attributes defined in Table 46.
Table 46 – ConfigurationGroupType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Design |
Static design properties for a pump. |
Implementation |
Static implementation properties for a pump. |
SystemRequirements |
Static system requirement properties for a pump. |
The DesignType provides static Variables for design properties, describing the limitations and working conditions of a Pump and is formally defined in Table 47.
Table 47 – DesignType Definition
Attribute |
Value |
|||||
BrowseName |
DesignType |
|||||
IsAbstract |
False |
|||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
|
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
||||||
0:HasComponent |
Variable |
AdditionalFieldbuses |
0:String [128] |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
BalancingRateOfFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
BasePressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
ClearanceVolume |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
ClockwiseRotation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Controllable |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
Cool_DownTimeForAVaporJetPumpOrADiffusionPump |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
Counter_ClockwiseRotation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
CriticalSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
DeclarationOfConformity |
0:String |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
DeclarationOfConformityAvailable |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
|
0:HasComponent |
Variable |
DesignAxialLoad |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
DesignRadialLoad |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
DirectivesOfEUDeclarationOfConformity |
DeclarationOfConformityOptionSet |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
DryCriticalSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
ExplosionProtection |
ExplosionProtectionOptionSet |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
GeometricalFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
GeometricDisplacementVolume |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
HeadAtPeakPoint |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Object |
InstallationNpshCurve |
|
0:FileType |
O |
|
0:HasComponent |
Variable |
LeakageRateOfFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableAmbientTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableCasingWorkingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableContinuousSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableHead |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableRelativeHumidity |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableThroughput |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAllowableWorkingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumAxialLoad |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumPumpPowerInput |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumRadialLoad |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MaximumStaticSealingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MeanTimebetweenFailures |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableAmbientTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableContinuousSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableHead |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableRelativeHumidity |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumAllowableThermalFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumContinuousStableFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
MinimumContinuousThermalFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
NetPositiveSuctionHeadRequired |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
NetPositiveSuctionHeadRequiredForADropOf3Percent |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
OfferedControlModes |
OfferedControlModesOptionSet |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
OfferedFieldbuses |
OfferedFieldbusesOptionSet |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
OptimumHead |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
OptimumPumpPowerInput |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
OptimumRateOfFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
PistonVelocity |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
PossibleFluids |
0:String [] |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
Pre_ChargePressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
PumpClass |
PumpClassEnum |
0:DataItemType |
O, RO |
|
0:HasComponent |
Object |
PumpCurve |
|
0:FileType |
O |
|
0:HasComponent |
Object |
PumpEfficiencyCurve |
|
0:FileType |
O |
|
0:HasComponent |
Object |
PumpH_Q_Curve |
|
0:FileType |
O |
|
0:HasComponent |
Object |
PumpNpshCurve |
|
0:FileType |
O |
|
0:HasComponent |
Object |
PumpPowerInputCurve |
|
0:FileType |
O |
|
0:HasComponent |
Variable |
Shut_OffHead |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
Shut_OffPumpPowerInput |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SlipFlow |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundEnergy |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundEnergyLevel |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundPower |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundPowerLevel |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundPressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SoundPressureLevel |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SpecificSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Object |
StablePumpH_Q_Curve |
|
0:FileType |
O |
|
0:HasComponent |
Variable |
StandardGasFlowrate |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
StartingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
Suction_SpecificSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
SweptVolume |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
TripSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
TypeNumber |
0:Double |
0:DataItemType |
O, RO |
|
0:HasComponent |
Variable |
VolumeFlowRate |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
VolumeFlowRateOfBackingPump |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
WarmUpTimeForAVaporJetPumpOrADiffusionPump |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
WaterVaporTolerableLoad |
0:Double |
0:BaseAnalogType |
O, RO |
|
0:HasComponent |
Variable |
WetCriticalSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
The optional Variable AdditionalFieldbuses is a one dimensional array with a limit of 128 entries.
The optional Variable PossibleFluids is a one dimensional array without a limit for possible entries.
The InstanceDeclarations of the DesignType have additional Attributes defined in Table 48. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN EN ISO 17769-2, DIN ISO 21360-1, ISO 3529-2, DIN 28400-2, DIN EN ISO 80000-8, ISO/TR 25417 and DIN EN 13306.
Table 48 – DesignType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
AdditionalFieldbuses |
|
Additional fieldbuses supported by the product. |
||
BalancingRateOfFlow |
|
Rate of flow which is extracted to activate a balance device |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
BasePressure |
|
Pressure obtained in the test dome after conditioning the vacuum pump and the test dome |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
ClearanceVolume |
|
Volume remaining unswept at the end of the discharge stroke. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067857 DisplayName: m³ Description: cubic metre |
|
||
ClockwiseRotation |
|
Direction of rotation in which the shaft is seen to be turning in a clockwise direction when viewing the drive end of the shaft. A "True" status means that the rotation of pump is clockwise and a "False" status means that the rotation of pump is anticlockwise. |
||
Controllable |
|
Indicates whether the product is a controllable pump or a self-controlling pump. A "True" status means that the pump is controllable and a "False" status means that the pump is not controllable. |
||
Cool_DownTimeForAVaporJetPumpOrADiffusionPump |
|
The cool-down time is the time required to cool the propellant from the working temperature to a temperature at which the propellant can be exposed to atmospheric air without risk after the heating has been switched off. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5457219 DisplayName: s Description: second [unit of time] |
|
||
Counter_ClockwiseRotation |
|
Direction of rotation in which the shaft is seen to be turning in an anticlockwise direction, when viewing the drive end of the shaft. A "True" status means that the rotation of pump is anticlockwise and a "False" status means that the rotation of pump is clockwise. |
||
CriticalSpeed |
|
Speed of rotation at which the frequency of vibration (or its multiples) corresponds to the rotor resonant (lateral or torsional) |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
DeclarationOfConformity |
|
Publicly accessible attestation of conformity, commonly available on websites. |
||
DeclarationOfConformityAvailable |
|
Whether or not a declaration of conformity exists. A "True" status means that the declaration exists and a "False" status means that there is no declaration available. |
||
DesignAxialLoad |
|
Residual axial thrust on the pump rotor on which the thrust-bearing selection is based. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
DesignRadialLoad |
|
Radial load of the pump rotor for which the bearing system is selected. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
DirectivesOfEUDeclarationOfConformity |
|
Set of directives on the basis of which conformity was determined. |
||
DryCriticalSpeed |
|
Rotor resonant frequency calculated assuming that the rotor is supported only at its bearings and that the bearings are of infinite stiffness |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
ExplosionProtection |
|
Device category for explosion protection according to 2014/34/EU (ATEX). |
||
GeometricalFlow |
|
Product of geometrical displacement volume and speed of rotation or stroke frequency |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
GeometricDisplacementVolume |
|
Displacement volume for one stroke or one cycle. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067857 DisplayName: m³ Description: cubic metre |
|
||
HeadAtPeakPoint |
|
Highest total head developed by a pump when this does not occur at a zero rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
InstallationNpshCurve |
|
Relationship between the net positive suction head available and the rate of flow at given operating conditions for a given liquid |
||
LeakageRateOfFlow |
|
Rate of flow leaking from shaft seals |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MaximumAllowableAmbientTemperature |
|
Highest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MaximumAllowableCasingWorkingPressure |
|
Greatest outlet pressure at the specified operating temperature at which the pump casing can be used |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumAllowableContinuousSpeed |
|
Highest rotational speed for continuous operation recommended by the manufacturer |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
MaximumAllowableHead |
|
Maximum permissible head at which the pump can be continuously operated without suffering damage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MaximumAllowableRelativeHumidity |
|
Highest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
MaximumAllowableTemperature |
|
Highest allowable continuous fluid temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MaximumAllowableThroughput |
|
Maximum pV flow the pump can withstand without damage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4665393 DisplayName: Pa·m³/s Description: pascal cubic metre per second |
|
||
MaximumAllowableWorkingPressure |
|
Pressure for a component on the basis of materials used and on the basis of calculation rules at the specified operating temperature |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumAxialLoad |
|
Greatest value of the residual axial thrust on the pump rotor resulting from operating the pump at any condition within its allowable operating range. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
MaximumPumpPowerInput |
|
Highest value of the pump power input at any rate of flow at any allowable operating condition |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
MaximumRadialLoad |
|
Greatest radial load of the pump rotor resulting from operating the pump at any condition within its allowable operating range. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
MaximumStaticSealingPressure |
|
Highest pressure, excluding hydrostatic testing, to which the seal can be subjected while the pump is shut down |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MeanTimebetweenFailures |
|
Average of the times between failures. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MinimumAllowableAmbientTemperature |
|
Lowest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MinimumAllowableContinuousSpeed |
|
Lowest speed for continuous operation recommended by the manufacturer |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
MinimumAllowableHead |
|
Minimum permissible head at which the pump can be operated without suffering damage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MinimumAllowableRelativeHumidity |
|
Lowest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
MinimumAllowableTemperature |
|
Lowest allowable continuous temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MinimumAllowableThermalFlow |
|
Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MinimumContinuousStableFlow |
|
Lowest flow at which the pump can be operated without it adversely affecting its performance in terms of life expectancy, noise and vibrations |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MinimumContinuousThermalFlow |
|
Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
NetPositiveSuctionHeadRequired |
|
Minimum NPSH at the pump inlet connection required to give the rated or operating performance at the specified conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
NetPositiveSuctionHeadRequiredForADropOf3Percent |
|
NPSH required for a drop of 3 % in the total head of the first stage of the pump as a standard basis for use in performance curves |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
OfferedControlModes |
|
Control modes supported by the manufacturer for the product. |
||
OfferedFieldbuses |
|
Fieldbuses supported by the manufacturer for the product. |
||
OptimumHead |
|
Total head developed by the pump at a rate of flow corresponding to the best efficiency |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
OptimumPumpPowerInput |
|
Pump power input at the rate of flow corresponding to the best efficiency |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
OptimumRateOfFlow |
|
Rate of flow at the point of best efficiency |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
PistonVelocity |
|
Average speed given by the stroke length multiplied with the number of complete pumping cycles of the piston, plunger or piston attached to the diaphragm per minute (stroke per minute or pump crank speed) |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
PossibleFluids |
|
Fluids that can be pumped by the pump. |
||
Pre_ChargePressure |
|
Pressure to which the pulsation dampener is charged with dry gas prior to start of operation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
PumpClass |
|
Pump type according to functional principle and pumped fluid |
||
PumpCurve |
|
Representation of the pump head plotted against the flow rate |
||
PumpEfficiencyCurve |
|
Relationship between the pump efficiency and the rate of flow at given operating conditions of speed and liquid |
||
PumpH_Q_Curve |
|
Relationship between the total head of the pump and the rate of flow at given operating conditions /rated conditions of speed and liquid |
||
PumpNpshCurve |
|
Relationship between the net positive suction head required and the rate of flow at given operating conditions of speed and liquid |
||
PumpPowerInputCurve |
|
Relationship between the pump power input and the rate of flow given operating conditions of speed and liquid |
||
Shut_OffHead |
|
Total head developed by the pump in a zero rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
Shut_OffPumpPowerInput |
|
Pump power input at zero rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
SlipFlow |
|
Flow lost internally through clearances |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
SoundEnergy |
|
Integral of the sound power, P, over a stated time interval of duration T (starting at t1 and ending at t2). |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4869973 DisplayName: J Description: joule |
|
||
SoundEnergyLevel |
|
Ten times the logarithm to the base 10 of the ratio of the sound energy, J, to a reference value, J0, expressed in decibels. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
SoundPower |
|
Through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
SoundPowerLevel |
|
Ten times the logarithm to the base 10 of the ratio of the sound power of a source, P, to a reference value, P0, expressed in decibels. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
SoundPressure |
|
Difference between instantaneous pressure and static pressure. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
SoundPressureLevel |
|
Ten times the logarithm to the base 10 of the ratio of the square of the sound pressure, p, to the square of a reference value, p0, expressed in decibels. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
SpecificSpeed |
|
Speed that characterizes a pump in terms of its speed, flow rate per impeller eye, i.e. total flow for single-flow impeller, half flow for double-flow impeller, at the best efficiency point and head per stage at maximum impeller diameter |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
StablePumpH_Q_Curve |
|
Pump H(Q) curve where the maximum head and shut-off head are coincidental, and the total head declines continuously as the rate of flow increases |
||
StandardGasFlowrate |
|
Volume flow rate at standard reference conditions, i.e. 0 °C and 101 325 Pa |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
StartingPressure |
|
The starting pressure is the pressure at which a vacuum pump can be switched on and a pumping effect is achieved without damage occurring. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
Suction_SpecificSpeed |
|
Speed that characterizes a pump's cavitation performance in terms of its speed, optimum rate of flow per impeller eye at best efficiency point and NPSH3 at best efficiency point for the first stage at maximum impeller diameter |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
SweptVolume |
|
Volume traversed by a single stroke of piston, plunger or diaphragm. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067857 DisplayName: m³ Description: cubic metre |
|
||
TripSpeed |
|
Speed at which the independent emergency overspeed devices operate to shut down a prime mover |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
TypeNumber |
|
Pure number calculated at the point of best efficiency |
||
VolumeFlowRate |
|
Volume flow rate of the gas removed by the pump from the gas phase within the evacuated chamber. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
VolumeFlowRateOfBackingPump |
|
Maximum volume flow rate for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
WarmUpTimeForAVaporJetPumpOrADiffusionPump |
|
The warm-up time is the time required to heat the blowing agent in the boiling vessel to its working temperature. The initial temperature can either be equal to the ambient temperature or equal to the temperature at which the blowing agent of the vacuum pump can be exposed to atmospheric air without risk. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5457219 DisplayName: s Description: second [unit of time] |
|
||
WaterVaporTolerableLoad |
|
The mass flow rate for water vapor, in a gas ballast pump, in continuous operation and under normal ambient conditions, if the pumped gas is pure water vapor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4933459 DisplayName: kg/s Description: kilogram per second |
|
||
WetCriticalSpeed |
|
Rotor resonant frequency calculated considering the additional support and damping produced by the action of the pumped fluid within rotor |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
The SystemRequirementsType provides static Variables for parameters of the process in which the Pump is to be used and is formally defined in Table 49.
Table 49 – SystemRequirementsType Definition
Attribute |
Value |
||||
BrowseName |
SystemRequirementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
CompressionRatio |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ExplosionZone |
ExplosionZoneOptionSet |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
Fieldbus |
FieldbusEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
Fluid |
0:String |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
GasContent |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfTheInletSideOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfTheOutletSideOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfThePump |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumAmbientTemperature |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumHead |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumInletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumOutletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumRelativeHumidity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumTemperature |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MeanTimeBetweenFailures |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumAmbientTemperature |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumHead |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumInletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumOutletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumRelativeHumidity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumTemperature |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
Multi_Phase |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
NetPositiveInletPressureAvailable |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
NormalFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
NpshDatumPlane |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
OperatingMode |
OperatingModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
RatedInletPressureOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedPumpUnitTotalHead |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ReferencePlane |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RequiredControlMode |
ControlModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
RequiredTime |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
SolidContent |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
Throughput |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
UltimatePressureOfAVacuumPump |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
WorkingTemperature |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the SystemRequirementsType have additional Attributes defined in Table 50. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN ISO 21360-1, ISO 3529-2, DIN 28400-2, DIN EN 13306 and VDI 3805-4.
Table 50 – SystemRequirementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
CompressionRatio |
|
Ratio of the backing pressure, p3, to the inlet pressure, p1, of the vacuum pump without throughput |
||
ExplosionZone |
|
Categories of explosion zones for devices according to 2014/34/EU (ATEX). |
||
Fieldbus |
|
Selected fieldbus for the product |
||
Fluid |
|
Fluid that is handled by the pump at specified operating conditions |
||
GasContent |
|
Proportion of gaseous substance in the liquid to be pumped, either as a contaminant or as vapor from the main body of liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
HeightOfTheInletSideOfTheInstallation |
|
Height of the fluid level on the inlet side of the installation, or in the center of the inlet manifold |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
HeightOfTheOutletSideOfTheInstallation |
|
Height of the fluid level on the outlet side of the installation or in the center of the outlet manifold |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
HeightOfThePump |
|
Height of the center of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MaximumAmbientTemperature |
|
Highest ambient temperature to be expected under normal circumstances |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MaximumFlow |
|
Greatest rate of flow which is expected at operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MaximumHead |
|
Highest total head developed by a pump at any rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MaximumInletPressure |
|
Highest inlet pressure to which the pump is subjected during operation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumOutletPressure |
|
Maximum possible pressure at outlet, due either to internal energy increase (rotodynamic pumps) or external downstream restrictions (volumetric pumps) |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumRelativeHumidity |
|
Highest relative humidity that can be expected under normal circumstances. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
MaximumTemperature |
|
Highest fluid temperature to be expected under operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MeanTimeBetweenFailures |
|
Average of the times between failures |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
MinimumAmbientTemperature |
|
Lowest ambient temperature to be expected under normal circumstances |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
MinimumFlow |
|
Smallest rate of flow which is expected at operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MinimumHead |
|
Smallest total head developed by a pump at any rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MinimumInletPressure |
|
Lowest inlet pressure that can occur during operation for the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MinimumOutletPressure |
|
Lowest outlet pressure that can occur during operation for the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MinimumRelativeHumidity |
|
Lowest relative humidity to be expected under normal circumstances. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
MinimumTemperature |
|
Lowest fluid temperature to be expected under operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
Multi_Phase |
|
Comprising a fluid together with substances in solid or gaseous states, whether due to deliberate addition or a change of state caused by a change in conditions. A "True" status means that there is a possibility of multi-phase-fluid and a "False" status means that there is no possibility of multi-phase-fluid. |
||
NetPositiveInletPressureAvailable |
|
Total pressure (including velocity pressure) at the pump inlet connection less the liquid vapor pressure at the present temperature of the liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
NormalFlow |
|
Rate of flow at which usual operation is expected |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
NpshDatumPlane |
|
Horizontal plane through the center of the circle described by the external points of the entrance edges of the impeller blades, in the first stage in the case of multi-stage pumps |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
OperatingMode |
|
Specifies whether the pump is to be operated in single, parallel or series connection. |
||
RatedInletPressureOfTheInstallation |
|
Inlet pressure of the installation for the working conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
RatedPumpUnitTotalHead |
|
Difference of the total head, at the outlet side of the pump unit from the total head at the inlet side of the pump unit, at which usual operation is expected |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
ReferencePlane |
|
Any horizontal plane for use as the datum for height measurement |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
RequiredControlMode |
|
Specifies which control mode is to be used for the use case. |
||
RequiredTime |
|
Time interval throughout which an item is required to be in an up state |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
SolidContent |
|
Proportion of solids contained in the fluid to be pumped, either as a contaminant or as a deliberate useful burden or suspension |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
Throughput |
|
Amount of fluid flowing through a duct |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4665393 DisplayName: Pa·m³/s Description: pascal cubic metre per second |
|
||
UltimatePressureOfAVacuumPump |
|
The ultimate pressure is the value to which the pressure in a standardized test dome approaches asymptotically during normal operation of the vacuum pump and without gas inlet. A difference can be made between the final pressure caused by gases and the final pressure caused by gases and vapors. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
WorkingTemperature |
|
Temperature determined by the given application and fluid. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
The ImplementationType provides static Variables for preconfiguring a Pump for the process in which the Pump is to be used and is formally defined in Table 51.
Table 51 – ImplementationType Definition
Attribute |
Value |
||||
BrowseName |
ImplementationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
AtmosphericPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
Density |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
DynamicViscosity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfTheInletManometer |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfTheNpshDatumPlane |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HeightOfTheOutletManometer |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
HydraulicEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
InstallationTotalHead |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
KinematicViscosity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumAllowableFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MaximumDynamicSealingPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedMeanVelocityAtInletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedMeanVelocityAtOutletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MechanicalEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumAllowableFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MinimumAllowableStableFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
NetPositiveSuctionHeadAvailable |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
OverallEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
PumpBestEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
PumpEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
PumpMechanicalPowerLosses |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
PumpRatedPowerInput |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
PumpTotalHead |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedDifferentialPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedFlow |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedSpeed |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
TotalHeadAtInletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
TotalHeadAtOutletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
UsefulLife |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ValveSeatVelocity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ValveSpillVelocity |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
VaporPressureOfThePumpedLiquid |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
VolumetricEfficiency |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the ImplementationType have additional Attributes defined in Table 52. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1 and DIN EN 13306.
Table 52 – ImplementationType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
AtmosphericPressure |
|
Mean absolute pressure of the atmosphere measured at the place of installation (2.1.1.3) of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
Density |
|
Volumetric mass at a stated temperature |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4934993 DisplayName: kg/m³ Description: kilogram per cubic metre |
|
||
DynamicViscosity |
|
Ratio of the shear stress to the shear velocity acting in a liquid subjected to a plane shear motion |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4404789 DisplayName: Pa·s Description: pascal second |
|
||
HeightOfTheInletManometer |
|
Height of the zero or center position of the inlet manometer, or other point as defined by the manometer calibration |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
HeightOfTheNpshDatumPlane |
|
Difference between the NPSH datum plane and the reference plane |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
HeightOfTheOutletManometer |
|
Height of the zero or center position of the outlet manometer, or other point as defined by the manometer calibration |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
HydraulicEfficiency |
|
Proportion of pump available power input, Pa, which is delivered as pump power output, Pu, after satisfying the losses resulting from friction due to the relative motion of internal surfaces and internal leakage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
InstallationTotalHead |
|
Difference between the total head at the outlet side of the installation and the total head at the inlet side of the installation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
KinematicViscosity |
|
Ratio of the dynamic viscosity to the density of the pumped liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 21300 DisplayName: m²/s Description: square metre per second |
|
||
MaximumAllowableFlow |
|
Greatest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MaximumDynamicSealingPressure |
|
Highest pressure expected at the shaft seals during any specified operating condition and during startup and shutdown |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
RatedMeanVelocityAtInletAreaOfTheInstallation |
|
Rated flow at the inlet area of the installation divided by the inlet area of the installation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
RatedMeanVelocityAtOutletAreaOfTheInstallation |
|
Rated flow at the outlet area of the installation divided by the inlet area of the installation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
MechanicalEfficiency |
|
Proportion of the pump power input, P, available after satisfying the mechanical power losses, PJ,ab, at given operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
MinimumAllowableFlow |
|
Smallest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
MinimumAllowableStableFlow |
|
Lowest flow at which the pump can operate without exceeding the noise and vibration limits imposed in the order |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
NetPositiveSuctionHeadAvailable |
|
Minimum NPSH available at the inlet area of the pump as determined by the conditions of the installation for a specified rate of flow |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
OverallEfficiency |
|
Proportion of the driver power input, Pmot, delivered as pump power output, Pu |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
PumpBestEfficiency |
|
Greatest value of pump efficiency obtained at given operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
PumpEfficiency |
|
Proportion of the pump power input, P, delivered as pump power output, Pu, at given operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
PumpMechanicalPowerLosses |
|
Power absorbed by friction in bearings and shaft seal at given operating conditions of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
PumpRatedPowerInput |
|
Power required by the pump at the rated conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
PumpTotalHead |
|
Difference between the total head at the outlet side of the pump and the total head at the inlet side of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
RatedDifferentialPressure |
|
Differential pressure for the operating conditions at the guarantee point |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
RatedFlow |
|
Rate of flow at the guarantee point |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
RatedSpeed |
|
Number of revolutions of the pump in a given time required to meet the rated conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
TotalHeadAtInletAreaOfTheInstallation |
|
Head observed at inlet area of the installation, corresponding to the sum of the height, pressure head and velocity head |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
TotalHeadAtOutletAreaOfTheInstallation |
|
Head observed at outlet area of the installation, corresponding to the sum of the height, pressure head and velocity head |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
UsefulLife |
|
Time interval from first use until the instant when a limiting state is reached |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740434 DisplayName: h Description: hour |
|
||
ValveSeatVelocity |
|
Mean velocity of the flow through the valve seat at the specified operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
ValveSpillVelocity |
|
Mean velocity of the flow through the valve spill area |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
VaporPressureOfThePumpedLiquid |
|
Absolute pressure at which the fluid vaporizes corresponding to the temperature of the liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
VolumetricEfficiency |
|
Ratio of the actual delivered volume at maximum pressure to the geometric displacement volume |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
The OperationalGroupType provides FunctionalGroups that collect Nodes for process data that is used during normal Pump operation, such as measurements, signals, and actuation. It is illustrated in Figure 14 and formally defined in Table 53.
Figure 14 – Illustration of OperationalGroupType
Table 53 – OperationalGroupType Definition
Attribute |
Value |
||||
BrowseName |
OperationalGroupType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
BypassActuation |
|
ActuationType |
O |
0:HasComponent |
Object |
Control |
|
ControlType |
O |
0:HasComponent |
Object |
Measurements |
|
MeasurementsType |
O |
0:HasComponent |
Object |
MultiPump |
|
MultiPumpType |
O |
0:HasComponent |
Object |
PumpActuation |
|
PumpActuationType |
O |
0:HasComponent |
Object |
Signals |
|
SignalsType |
O |
0:HasComponent |
Object |
ThrottleValveActuation |
|
ActuationType |
O |
The InstanceDeclarations of the OperationalGroupType have additional Attributes defined in Table 54.
Table 54 – OperationalGroupType Attribute values for child Nodes
BrowsePath |
Description Attribute |
BypassActuation |
Actuation parameters for a bypass valve of a pump. |
Control |
Control parameters for a pump. |
Measurements |
Measurements at a pump. |
MultiPump |
Properties for multi pump usage of a pump. |
PumpActuation |
Actuation parameters for a pump. |
Signals |
Signals of a pump. |
ThrottleValveActuation |
Actuation parameters for a throttle valve of a pump. |
The ControlType provides Variables for precise control of a Pump according to DIN IEC 60050-351 and is formally defined in Table 55.
Table 55 – ControlType Definition
Attribute |
Value |
||||
BrowseName |
ControlType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
CommandVariable |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ControlDifferenceVariable |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ControlledVariable |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ControllerOutputVariable |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DeadTime |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
DerivativeActionCoefficient |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
FeedbackVariable |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
FinalControlledVariable |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
IntegralActionCoefficient |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ManipulatedVariable |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
OperatingMode |
0:String |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
ProportionalActionCoefficient |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
ReferenceVariable |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the ControlType have additional Attributes defined in Table 56. The Variables and the associated Descriptions are based on the standard DIN IEC 60050-351.
Table 56 – ControlType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
CommandVariable |
|
Variable quantity, which is not influenced by the control but is introduced into the control system from outside with the aim of making the final controlled variable follow it in a given relationship |
||
ControlDifferenceVariable |
|
Difference between the reference variable and the feedback variable |
||
ControlledVariable |
|
Output variable of the controlled system that will be acted upon by one or more manipulated variables |
||
ControllerOutputVariable |
|
Output variable of the controlling element, which is deducted from the control difference variable and is also the input variable of the actuator |
||
DeadTime |
|
In a dead-time element the duration of the time interval by which the output variable is shifted relative to the input variable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5457219 DisplayName: s Description: second [unit of time] |
|
||
DerivativeActionCoefficient |
|
For a derivative element, the quotient of the value of the output variable to the value of the time derivative of the input variable |
||
FeedbackVariable |
|
Variable quantity, which represents the controlled variable and is returned to the comparing element |
||
FinalControlledVariable |
|
Variable quantity which has, or combination of variable quantities which have, to be influenced by the control |
||
IntegralActionCoefficient |
|
For an integral element, the quotient of the time derivative of the output variable to the fixed value of the input variable |
||
ManipulatedVariable |
|
Output variable of the controlling system, which is also an input variable of the controlled system |
||
OperatingMode |
|
Characterization of the way and the extent to which the human operator intervenes in the control equipment |
||
ProportionalActionCoefficient |
|
For a proportional element, the quotient of the variation of the output variable to the corresponding variation of the input variable |
||
ReferenceVariable |
|
Input variable to a comparing element in a controlling system, which sets the desired value of the controlled variable and is deducted from the command variable |
The ActuationType provides general Variables for asset actuation. It is illustrated in Figure 15 and formally defined in Table 57.
Figure 15 – Illustration of ActuationType
Table 57 – ActuationType Definition
Attribute |
Value |
||||
BrowseName |
ActuationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasSubtype |
ObjectType |
PumpActuationType |
Defined in 7.26 |
||
|
|
|
|
|
|
0:HasComponent |
Variable |
FaultAction |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
FaultValue |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
FeedbackVariable |
0:Double |
0:AnalogUnitType |
O, RO |
0:HasComponent |
Variable |
ManipulatedValue |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
OnOff |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
ReferenceVariable |
0:Double |
0:AnalogUnitType |
O, RO |
0:HasComponent |
Variable |
Status |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
The InstanceDeclarations of the ActuationType have additional Attributes defined in Table 58. The Variables and the associated Descriptions are based on the standards VDMA 24223-1 and DIN IEC 60050-351.
Table 58 – ActuationType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
FaultAction |
|
This property determines the action taken on variables in fault state. If the value is TRUE, the value of the property Fault value is used, if it is FALSE, the last valid value is used |
||
FaultValue |
|
This property specifies a user-defined value for use with Fault action property |
||
FeedbackVariable |
|
Variable quantity, which represents the controlled variable and is returned to the comparing element |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
ManipulatedValue |
|
Output variable of the controlling system, which is also an input variable of the controlled system |
||
OnOff |
|
This property enables the operation. |
||
ReferenceVariable |
|
Input variable to a comparing element in a controlling system, which sets the desired value of the controlled variable and is deducted from the command variable |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
Status |
|
This property contains the actual status of the element |
The PumpActuationType extends its supertype by Pump specific Objects and Variables for discrete outputs according to VDMA 24223. It is illustrated in Figure 16 and formally defined in Table 59.
Figure 16 – Illustration of PumpActuationType
Table 59 – PumpActuationType Definition
Attribute |
Value |
||||
BrowseName |
PumpActuationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ActuationType defined in 7.25, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ActualControlMode |
ControlModeEnum |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
ActualOperationMode |
OperationModeEnum |
0:DataItemType |
O, RO |
0:HasComponent |
Object |
CleanValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Variable |
ControlInversion |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
Enable |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
ExternalSignal |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Object |
FlushValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Object |
GasDilValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Object |
InletValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Object |
OutletValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Object |
PumpKick |
|
PumpKickObjectType |
O |
0:HasComponent |
Object |
PumpStandByRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Object |
PurgeValveRequest |
|
DiscreteOutputObjectType |
O |
0:HasComponent |
Variable |
ReverseRotatingDirection |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SetControlMode |
ControlModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
SetOperationMode |
OperationModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Object |
VentValveRequest |
|
DiscreteOutputObjectType |
O |
The InstanceDeclarations of the PumpActuationType have additional Attributes defined in Table 60. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 60 – PumpActuationType Attribute values for child Nodes
BrowsePath |
Description Attribute |
ActualControlMode |
This property describes the actual control mode of the pump. |
ActualOperationMode |
This property describes the actual operation mode of the pump. |
CleanValveRequest |
This element offers a request for the opening of the clean valve. |
ControlInversion |
This property offers the inversion of the selected control mode in operation mode AutoControl. A "True" status means that the control mode inversion is activated and a "False" status means that the control mode inversion is deactivated. |
Enable |
This property activates of the control function. |
ExternalSignal |
This property offers the activation of an external electrical interface serving the setpoint of the control function by selecting the kind of electrical (analogue) signal. |
FlushValveRequest |
This element offers a request for the opening of the flush valve. |
GasDilValveRequest |
This element offers a request for the opening of the gas dilution valve. |
InletValveRequest |
This element offers a request for the opening of the inlet valve. |
OutletValveRequest |
This element offers a request for the opening of the outlet valve. |
PumpKick |
This element describes a periodical operation of a pump, avoiding blockage at non operation time. |
PumpStandByRequest |
This element offers a request for pump standby. |
PurgeValveRequest |
This element offers a request for the opening of the purge valve. |
ReverseRotatingDirection |
This property indicates the inversion of the standard rotating direction. |
SetControlMode |
This property describes the desired control mode of the pump. |
SetOperationMode |
This property describes the desired operation mode of the pump. |
VentValveRequest |
This element offers a request for the opening of the vent valve. |
The abstract DiscreteObjectType provides Variables for discrete inputs and outputs of a Pump. It is illustrated in Figure 17 and formally defined in Table 61.
Figure 17 – Illustration of DiscreteObjectType
Table 61 – DiscreteObjectType Definition
Attribute |
Value |
||||
BrowseName |
DiscreteObjectType |
||||
IsAbstract |
True |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:BaseObjectType defined in OPC 10000-5. |
|||||
0:HasSubtype |
ObjectType |
DiscreteInputObjectType |
Defined in 7.28 |
||
0:HasSubtype |
ObjectType |
DiscreteOutputObjectType |
Defined in 7.29 |
||
|
|
|
|
|
|
0:HasComponent |
Variable |
OnOffCycle |
0:UInt32 |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Status |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
The InstanceDeclarations of the DiscreteObjectType have additional Attributes defined in Table 62. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 62 – DiscreteObjectType Attribute values for child Nodes
BrowsePath |
Description Attribute |
OnOffCycle |
This property contains the total number of transitions of the value from the Off to the On state. |
Status |
This property contains the actual status of the element. |
The DiscreteInputObjectType extends its supertype by input specific Variables and is formally defined in Table 63.
Table 63 – DiscreteInputObjectType Definition
Attribute |
Value |
||||
BrowseName |
DiscreteInputObjectType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the DiscreteObjectType defined in 7.27, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
DiscreteInputValue |
0:Boolean |
0:TwoStateDiscreteType |
M, RO |
The InstanceDeclarations of the DiscreteInputObjectType have additional Attributes defined in Table 64. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 64 – DiscreteInputObjectType Attribute values for child Nodes
BrowsePath |
Description Attribute |
DiscreteInputValue |
This property contains the actual value of the discrete input unit. |
The DiscreteOutputObjectType extends its supertype by output specific Variables and is formally defined in Table 65.
Table 65 – DiscreteOutputObjectType Definition
Attribute |
Value |
||||
BrowseName |
DiscreteOutputObjectType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the DiscreteObjectType defined in 7.270, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasSubtype |
ObjectType |
PumpKickObjectType |
Defined in 7.30 |
||
|
|
|
|
|
|
0:HasComponent |
Variable |
DiscreteOutputValue |
0:Boolean |
0:TwoStateDiscreteType |
M, RW |
0:HasComponent |
Variable |
FaultAction |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
0:HasComponent |
Variable |
FaultValue |
0:Boolean |
0:TwoStateDiscreteType |
O, RW |
The InstanceDeclarations of the DiscreteOutputObjectType have additional Attributes defined in Table 66. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 66 – DiscreteOutputObjectType Attribute values for child Nodes
BrowsePath |
Description Attribute |
DiscreteOutputValue |
This property contains the actual value of the discrete output unit. |
FaultAction |
This property determines the action taken on variables in fault state. |
FaultValue |
This property specifies a user-defined value for use with Fault action property. |
The PumpKickObjectType extends its supertype by pump kick specific Variables and is formally defined in Table 67.
Table 67 – PumpKickObjectType Definition
Attribute |
Value |
||||
BrowseName |
PumpKickObjectType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the DiscreteOutputObjectType defined in 7.29, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
PumpKickMode |
PumpKickModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
PumpKickTime |
0:Double |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
PumpKickTimeDifference |
0:Double |
0:AnalogUnitType |
O, RW |
The InstanceDeclarations of the PumpKickObjectType have additional Attributes defined in Table 68. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 68 – PumpKickObjectType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description |
||
PumpKickMode |
|
This property describes the pump kick mode of the pump. |
||
PumpKickTime |
|
This property determines the absolute time of a pump kick, if Pump Kick Mode is operator specific. The time for the next pump kick results of the sum of Pump Kick Time and Pump Kick Time Difference |
||
PumpKickTimeDifference |
|
This property determines the interval time of a pump kick, if Pump Kick Mode is operator specific. The time for the next pump kick results of the sum of Pump Kick Time and Pump Kick Time Difference |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5457219 DisplayName: s Description: second [unit of time] |
|
The SignalsType provides Objects to provide feedback on the current Pump state and is formally defined in Table 69.
Table 69 – SignalsType Definition
Attribute |
Value |
||||
BrowseName |
SignalsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Acceleration |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
CleanValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
Deceleration |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
FlushValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
GasDilValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
InletValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
NoRotation |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
OutletValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
ProcessIsActive |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpActivation |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpDirection |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpOperation |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpPowerMax |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpSpeedMax |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PumpSpeedMin |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
PurgeValveOpen |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
RatedSpeed |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
StandBy |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
StandBySpeed |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
TargetSpeed |
|
DiscreteInputObjectType |
O |
0:HasComponent |
Object |
VentValveOpen |
|
DiscreteInputObjectType |
O |
The InstanceDeclarations of the SignalsType have additional Attributes defined in Table 70. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 70 – SignalsType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Acceleration |
This element serves a feedback that the pump rotation accelerates. |
CleanValveOpen |
This element serves a feedback about the open state of the cleaning valve. |
Deceleration |
This element serves a feedback that the pump rotation decelerates. |
FlushValveOpen |
This element serves a feedback about the open state of the flush valve. |
GasDilValveOpen |
This element serves a feedback about the open state of the gas dilution valve. |
InletValveOpen |
This element serves a feedback about the open state of the inlet valve. |
NoRotation |
This element serves a feedback that the pump stands still. |
OutletValveOpen |
This element serves a feedback about the open state of the outlet valve. |
ProcessIsActive |
This element serves a feedback that the process is active. |
PumpActivation |
This element serves a feedback about the activation state of the pump. The activation state takes into account that control mechanisms are active. Never the less the pump is not necessarily running |
PumpDirection |
This element serves a feedback of the pumps direction of rotation. |
PumpOperation |
This element serves a feedback about the operation state of the pump. In the operation state the pump rotor is rotating. |
PumpPowerMax |
This element serves a feedback of pump operating at maximum power. |
PumpSpeedMax |
This element serves a feedback of pump operating at maximum speed. |
PumpSpeedMin |
This element serves a feedback that the pump operates at minimum speed. |
PurgeValveOpen |
This element serves a feedback about the open state of the purge valve. |
RatedSpeed |
This element serves a feedback that the pump rotation is at rated speed. |
StandBy |
This element serves a feedback about the process standby of the pump. In the stand by state the pump is ready for operation. |
StandBySpeed |
This element serves a feedback that the pump rotation is at standby speed. |
TargetSpeed |
This element serves a feedback that the pump is at target speed. |
VentValveOpen |
This element serves a feedback about the open state of the vent valve. |
The MeasurementsType provides Objects and Variables used for measurements performed at a Pump. It is illustrated in Figure 18 and formally defined in Table 73. For the generation of events, the MeasurementsType has a reference to the 0:LimitAlarmType. The InputNode Property of the Alarm shall contain the NodeId of the Component. Measurements defined in this ObjectType have an additional Subcomponent with the TypeDefinition 0:PropertyType and the BrowseName KindOfQuantity defined in Table 72. In this Variables the measurements can be matched to a physical quantity. To comply with this Companion Specification, the default values for the Property 0:EngineeringUnits and the Property KindOfQuantity provided in Table 73 should be used. The values should be sensible to the use of the application.
Figure 18 – Illustration of MeasurementsType
Table 71 – MeasurementsType Definition
Attribute |
Value |
||||
BrowseName |
MeasurementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
<Vibration> |
|
VibrationMeasurementType |
OP |
0:HasComponent |
Variable |
AmbientHumidity |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
AmbientTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
AxialLoadOfPumpRotor |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
AxialRotorPosition |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BackPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BearingTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ClearanceFlow |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
CoolantTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Density |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DifferentialPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DynamicViscosity |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ElectronicTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
FluidTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
HousingTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
HydraulicEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
InletPressureOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
InstallationTotalHead |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
KinematicViscosity |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
LeakageRateOfFlow |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Level |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
LubricatingOilConsumption |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
LubricatingOilPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MassFlow |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MeanVelocityAtThroat |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MechanicalEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NetPositiveInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NetPositiveSuctionHead |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NumberOfStarts |
0:UInt32 |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OutletPressureOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PowerLossDueToInternalLeakage |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ProcessPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpHumidity |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpPowerInput |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpPowerOutput |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PumpTotalHead |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
RadialLoadOfPumpRotor |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundEnergy |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundEnergyLevel |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundPower |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundPowerLevel |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SoundPressureLevel |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Speed |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Throughput |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
TotalHeadAtInletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
TotalHeadAtOutletAreaOfTheInstallation |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VolumetricEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:GeneratesEvent |
ObjectType |
0:LimitAlarmType |
Defined in OPC 10000-9 |
The OptionalPlaceholder Object Vibration is used for multiple vibration measurements at a Pump.
Table 72 – MeasurementsType Additional Subcomponents
Source Path |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
AmbientHumidity |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
AmbientTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
AxialLoadOfPumpRotor |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
AxialRotorPosition |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
BackPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
BearingTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
ClearanceFlow |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
CoolantTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Density |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
DifferentialPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
DynamicViscosity |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
ElectronicTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
FluidTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
HousingTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
HydraulicEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
InletPressureOfTheInstallation |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
InstallationTotalHead |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
KinematicViscosity |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
LeakageRateOfFlow |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Level |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
LubricatingOilConsumption |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
LubricatingOilPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MassFlow |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MeanVelocityAtThroat |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MechanicalEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
NetPositiveInletPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
NetPositiveSuctionHead |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
NumberOfStarts |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
OutletPressureOfTheInstallation |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
OverallEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PowerLossDueToInternalLeakage |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
ProcessPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpHumidity |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpPowerInput |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpPowerOutput |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PumpTotalHead |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
RadialLoadOfPumpRotor |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundEnergy |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundEnergyLevel |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundPower |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundPowerLevel |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundPressure |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
SoundPressureLevel |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Speed |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Throughput |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
TotalHeadAtInletAreaOfTheInstallation |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
TotalHeadAtOutletAreaOfTheInstallation |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
VolumetricEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
The InstanceDeclarations of the MeasurementsType have additional Attributes defined in Table 73. The Variables and the associated Descriptions are based on the standards VDMA 24223, DIN EN 13306, DIN EN ISO 17769-1, DIN ISO 21360-1, ISO 2041, DIN EN ISO 80000-8, ISO/ TR 25417, ISO 7967-6, ISO 2710-1 and IEC61987.
Table 73 – MeasurementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
<Vibration> |
|
Properties characterizing dynamic data which are the result of an oscillation measurement at machines with rotating movements |
||
AmbientHumidity |
|
Measured ambient humidity |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“relative humidity” |
Quotient of partial pressure of water vapor and partial pressure at its saturation |
||
AmbientTemperature |
|
Measured ambient temperature |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
AxialLoadOfPumpRotor |
|
Measured residual thrust acting through the shaft derived from hydraulic or mechanical forces |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
|
“force” |
Vector quantity describing interaction between bodies or particles |
||
AxialRotorPosition |
|
Measured position of the axial rotor in bearing. |
||
|
“rational number” |
Element of a set of mathematical entities that includes all integers and other entities, each defined as the quotient of two integers, such that the division is defined for any two entities, except zero as a divisor |
||
BackPressure |
|
Measured back pressure of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
BearingTemperature |
|
Measured temperature of the bearing |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
ClearanceFlow |
|
Measured clearance flow between the housing and the impeller |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
|
“volume flow rate” |
Scalar quantity characterizing the total flow through the two-dimensional domain A with the normal vector of a flowing fluid with velocity as an integral |
||
CoolantTemperature |
|
Measured temperature of the coolant. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
Density |
|
Measured density of the fluid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4934993 DisplayName: kg/m³ Description: kilogram per cubic metre |
|
||
|
“density” |
Quantity representing the spatial distribution of mass of a continuous material |
||
DifferentialPressure |
|
Determined (actual) gain in total pressure between the pump inlet and pump outlet |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
DynamicViscosity |
|
Measured kinematic viscosity of the fluid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4665393 DisplayName: Pa·m³/s Description: pascal cubic metre per second |
|
||
|
“dynamic viscosity” |
For laminar flows, proportionality constant between shear stress in a fluid moving with a velocity and gradient perpendicular to the plane of shear |
||
ElectronicTemperature |
|
Measured temperature of the electronic |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
FluidTemperature |
|
Measured internal temperature of pump fluid. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
HousingTemperature |
|
Measured temperature of the housing |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
HydraulicEfficiency |
|
Determined proportion of pump available power input, Pa, which is delivered as pump power output, Pu, after satisfying the losses resulting from friction due to the relative motion of internal surfaces and internal leakage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind |
||
InletPressureOfTheInstallation |
|
Measured pressure at the inlet area of the installation. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
InstallationTotalHead |
|
Determined difference between the total head at the outlet side of the installation and the total head at the inlet side of the installation |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre
|
|
||
|
“length” |
Linear extent in space between any two points |
||
KinematicViscosity |
|
Measured dynamic viscosity of the fluid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 21300 DisplayName: m²/s Description: square metre per second |
|
||
|
“kinematic viscosity” |
Quotient of dynamic viscosity and mass density of a fluid |
||
LeakageRateOfFlow |
|
Measured rate of flow leaking from shaft seals |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067091 DisplayName: m³/s Description: cubic metre per second |
|
||
|
“volume flow rate” |
Scalar quantity characterizing the total flow through the two-dimensional domain A with the normal vector of a flowing fluid with velocity as an integral |
||
Level |
|
Measured level |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
|
“length” |
Linear extent in space between any two points |
||
LubricatingOilConsumption |
|
Measured oil consumption of the lubricating system |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067857 DisplayName: m³ Description: cubic metre |
|
||
|
“volume” |
Extent of a three dimensional geometrical shape |
||
LubricatingOilPressure |
|
Measured oil pressure of the lubrication system |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
MassFlow |
|
Measure mass flow from the outlet area of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4933459 DisplayName: kg/s Description: kilogram per second |
|
||
|
“mass flow” |
Vector quantity characterizing a flowing fluid by the product of its local mass density and local velocity |
||
MeanVelocityAtThroat |
|
Measured rate of flow passing through the exit from the volute divided by the throat area |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
|
“velocity” |
Vector quantity giving the rate of change of a position vector |
||
MechanicalEfficiency |
|
Determined proportion of the pump power input, P, available after satisfying the mechanical power losses, PJ, ab, at given operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind |
||
NetPositiveInletPressure |
|
Total pressure (including velocity pressure) at the pump inlet connection less the liquid vapor pressure at the present temperature of the liquid |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
NetPositiveSuctionHead |
|
Amount of the absolute value of the total head above the head, equivalent to the vapor pressure of the liquid at the particular temperature, with reference to the NPSH datum plane |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
|
“length” |
Linear extent in space between any two points |
||
NumberOfStarts |
|
Total number of starts |
||
|
“rational number” |
Element of a set of mathematical entities that includes all integers and other entities, each defined as the quotient of two integers, such that the division is defined for any two entities, except zero as a divisor |
||
OutletPressureOfTheInstallation |
|
Measured pressure at the outlet area of the installation. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
OverallEfficiency |
|
Determined proportion of the driver power input, Pmot, delivered as pump power output, Pu |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind |
||
PowerLossDueToInternalLeakage |
|
Determined power loss due clearance flows |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
|
“power” |
Derivative with respect to time t of energy E being transferred or transformed |
||
ProcessPressure |
|
Measured process pressure of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
PumpEfficiency |
|
Determined proportion of the pump power input, P, delivered as pump power output, Pu, at given operating conditions |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind |
||
PumpHumidity |
|
Measured humidity inside the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“relative humidity” |
Quotient of partial pressure of water vapor and partial pressure at its saturation |
||
PumpPowerInput |
|
Measured power transmitted to the pump by its driver |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
|
“mechanical power” |
Scalar product of force acting to a body and its velocity |
||
PumpPowerOutput |
|
Measured useful mechanical power transferred to the fluid during its passage through the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
|
“mechanical power” |
Scalar product of force acting to a body and its velocity |
||
PumpTemperature |
|
Measured temperature of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
PumpTotalHead |
|
Determined difference between the total head at the outlet side of the pump and the total head at the inlet side of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
|
“length” |
Linear extent in space between any two points |
||
RadialLoadOfPumpRotor |
|
Measured residual force acting at right angles to the line of the shaft and derived from hydraulic forces |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
||
|
“force” |
Vector quantity describing interaction between bodies or particles |
||
SoundEnergy |
|
Determined integral of the sound power, P, over a stated time interval of duration T (starting at t1 and ending at t2) |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4869973 DisplayName: J Description: joule |
|
||
|
“energy“ |
Ability of a system to do work |
||
SoundEnergyLevel |
|
Determined ten times the logarithm to the base 10 of the ratio of the sound energy, J, to a reference value, J0, expressed in decibels |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
|
“sound level” |
Logarithm of the ratio of a given sound pressure to the reference sound pressure of 20 μPa, the sound pressure being obtained with a standard frequency weighting and with a standard exponential time weighting. Sound level in decibels is twenty times the logarithm to the base ten of that ratio |
||
SoundPower |
|
Determined through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
|
“power” |
Derivative with respect to time t of energy E being transferred or transformed |
||
SoundPowerLevel |
|
Determined ten times the logarithm to the base 10 of the ratio of the sound power of a source, P, to a reference value, P0, expressed in decibels |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
|
“sound level” |
Logarithm of the ratio of a given sound pressure to the reference sound pressure of 20 μPa, the sound pressure being obtained with a standard frequency weighting and with a standard exponential time weighting. Sound level in decibels is twenty times the logarithm to the base ten of that ratio |
||
SoundPressure |
|
Measured difference between instantaneous pressure and static pressure |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
|
“pressure” |
Quotient of the component of a force normal to a surface and its area |
||
SoundPressureLevel |
|
Determined ten times logarithm to the base 10 of the ratio of the square of the sound pressure, p, to the square of a reference value, p0, expressed in decibels |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 12878 DisplayName: dB Description: decibel |
|
||
|
“sound level” |
Logarithm of the ratio of a given sound pressure to the reference sound pressure of 20 μPa, the sound pressure being obtained with a standard frequency weighting and with a standard exponential time weighting. Sound level in decibels is twenty times the logarithm to the base ten of that ratio |
||
Speed |
|
Measured number of rotations or movements made by the shaft, coupling or impeller in a given time |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
|
“frequency” |
Inverse of one cycle of a periodic event |
||
Throughput |
|
Measured throughput of the vacuum pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4665393 DisplayName: Pa·m³/s Description: pascal cubic metre per second |
|
||
|
“volume flow rate” |
Scalar quantity characterizing the total flow through the two-dimensional domain A with the normal vector of a flowing fluid with velocity as an integral |
||
TotalHeadAtInletAreaOfTheInstallation |
|
Determined total head at the inlet area of the installation, which corresponds to the sum of geodetic head, pressure head and velocity head |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre
|
|
||
|
“length” |
Linear extent in space between any two points |
||
TotalHeadAtOutletAreaOfTheInstallation |
|
Determined total head at the outlet area of the installation, which corresponds to the sum of geodetic head, pressure head and velocity head |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
|
“length” |
Linear extent in space between any two points |
||
VolumetricEfficiency |
|
Determined ratio of the actual delivered volume at maximum pressure to the geometric displacement volume |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind. |
The VibrationMeasurementType provides Variables for Pump vibration measurements according to IEC61987 and is formally defined in Table 74.
Table 74 – VibrationMeasurementType Definition
Attribute |
Value |
||||
BrowseName |
VibrationMeasurementType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
1XPhase |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
1XRelativeShaftVibrationP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
2XPhase |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
2XRelativeShaftVibrationP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BearingIndex |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BearingIndexPerG |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BroadbandCavitationAccelerationPerG_RMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
BroadbandCavitationAccelerationRMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
GapVoltage |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Not1XRelativeShaftVibrationP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAcceleration0_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAccelerationP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAccelerationPerG0_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAccelerationPerG_RMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAccelerationPerGP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationAccelerationRMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationDisplacementP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationDisplacementRMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationVelocity0_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationVelocityP_P |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OverallVibrationVelocityRMS |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ReferenceStandardForVibrationMeasurement |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
RotationalPhase1X |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
RotationalPhase2X |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
SpeedOfRotation |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ThrustPosition |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheBearingDefectFrequencies |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheBearingDefectFrequenciesPerG |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheBladePassFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheFirstHarmonicOfTheRotationFrequency2X |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheGearMeshingFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheGearMeshingFrequencyPerG |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheHarmonicsOfTheRotationFrequencyNx |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheRotationFrequency1X |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheSidebandsOfTheGearMeshingFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
VibrationAmplitudeAtTheSidebandsOfTheGearMeshingFrequencyPerG |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the VibrationMeasurementType have additional Attributes defined in Table 75. The Variables and the associated Descriptions are based on the standard IEC61987.
Table 75 – VibrationMeasurementType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
1XPhase |
|
Phase of the 1X relative shaft vibration related to a reference point of time. The reference point of time for the phase is defined by a so called phase reference sensor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 17476 DisplayName: ° Description: degree [unit of angle] |
|
||
1XRelativeShaftVibrationP_P |
|
Oscillation range at the rotation frequency of the shaft under consideration, expressed as displacement. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 13384 DisplayName: µm Description: micrometre (micron) |
|
||
2XPhase |
|
Phase of the 2X relative shaft vibration related to a reference point of time. The reference point of time for the phase is defined by a so called phase reference sensor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 17476 DisplayName: ° Description: degree [unit of angle] |
|
||
2XRelativeShaftVibrationP_P |
|
Oscillation range at the double rotation frequency of the shaft under consideration, expressed as displacement. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 13384 DisplayName: µm Description: micrometre (micron) |
|
||
BearingIndex |
|
Amplitude of the oscillation envelope after high pass filtering, expressed as acceleration. The parameter for the high pass filtering and oscillation envelope are regularly defined by the user. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
BearingIndexPerG |
|
Amplitude of the oscillation envelope after high pass filtering, expressed as acceleration in units of the acceleration of gravity g. The parameter for the high pass filtering and oscillation envelope are regularly defined by the user. |
||
BroadbandCavitationAccelerationPerG_RMS |
|
Root mean square of the oscillation signal due to cavitation within a defined frequency range, expressed as acceleration in units of the acceleration of gravity g. The frequency range is regularly defined by the user. |
||
BroadbandCavitationAccelerationRMS |
|
Root mean square of the oscillation signal due to cavitation within a defined frequency range, expressed as acceleration. The frequency range is regularly defined by the user. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
GapVoltage |
|
Sum value of the oscillation ranges of the vibration at all frequencies except the rotation frequency of the shaft under consideration, expressed as displacement. Regularly, only the frequency range below the rotational frequency is considered. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5655636 DisplayName: V Description: volt |
|
||
Not1XRelativeShaftVibrationP_P |
|
Phase of the 2X relative shaft vibration related to a reference point of time. The reference point of time for the phase is defined by a so called phase reference sensor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 13384 DisplayName: µm Description: micrometre (micron) |
|
||
OverallVibrationAcceleration0_P |
|
Maximum oscillation amplitude, expressed as acceleration. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
OverallVibrationAccelerationP_P |
|
Oscillation range, expressed as acceleration. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
OverallVibrationAccelerationPerG0_P |
|
Maximum oscillation amplitude, expressed as acceleration in units of the acceleration of gravity g. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
OverallVibrationAccelerationPerG_RMS |
|
Root mean square of the oscillation displacement, expressed as acceleration in units of the acceleration of gravity g |
||
OverallVibrationAccelerationPerGP_P |
|
Oscillation range, expressed as acceleration in units of the acceleration of gravity g. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
OverallVibrationAccelerationRMS |
|
Root mean square of the oscillation displacement, expressed as acceleration |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
OverallVibrationDisplacementP_P |
|
Oscillation range, expressed as local displacement. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 13384 DisplayName: µm Description: micrometre (micron) |
|
||
OverallVibrationDisplacementRMS |
|
Root mean square of oscillation range, expressed as local displacement. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 13384 DisplayName: µm Description: micrometre (micron) |
|
||
OverallVibrationVelocity0_P |
|
Maximum oscillation amplitude, expressed as velocity. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
OverallVibrationVelocityP_P |
|
Oscillation range, expressed as velocity. The oscillation range is the difference between the minimum and maximum value within the time range under consideration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
OverallVibrationVelocityRMS |
|
Root mean square of the oscillation displacement expressed as velocity |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
ReferenceStandardForVibrationMeasurement |
|
Standard to which statements on vibration measurement refer. |
||
RotationalPhase1X |
|
Phase of the vibration amplitude at the rotation frequency (1X) of the object under consideration related to a reference point of time. The reference point of time for the phase is defined by a so called phase reference sensor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 17476 DisplayName: ° Description: degree [unit of angle] |
|
||
RotationalPhase2X |
|
Phase of the vibration amplitude at the first harmonic of the rotation frequency (2X) of the object under consideration related to a reference point of time. The reference point of time for the phase is defined by a so called phase reference sensor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 17476 DisplayName: ° Description: degree [unit of angle] |
|
||
SpeedOfRotation |
|
Number of revolutions per time. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
ThrustPosition |
|
Measure for the distance between the sensor and the shaft, expressed as device output voltage |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5066068 DisplayName: mm Description: millimetre |
|
||
VibrationAmplitudeAtTheBearingDefectFrequencies |
|
Amplitude of the oscillation envelope at the roller bearing defect frequencies after high pass filtering, expressed as acceleration. The parameter for the high pass filtering and oscillation envelope are regularly defined by the user. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
VibrationAmplitudeAtTheBearingDefectFrequenciesPerG |
|
Amplitude of the oscillation envelope at the roller bearing defect frequencies after high pass filtering, expressed as acceleration in units of the acceleration of gravity g. The parameter for the high pass filtering and oscillation envelope are regularly defined by the user. |
||
VibrationAmplitudeAtTheBladePassFrequency |
|
Performance indicator of vibration calculated from the oscillation amplitude at the rotation frequency of the shaft multiplied with the number of blades mounted at the shaft, expressed as velocity. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
VibrationAmplitudeAtTheFirstHarmonicOfTheRotationFrequency2X |
|
Oscillation amplitude at the double rotation frequency of the object under consideration, expressed as velocity. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
VibrationAmplitudeAtTheGearMeshingFrequency |
|
Performance indicator of vibration calculated from the oscillation amplitude at the rotation frequency of the shaft, multiplied with the number of teeth of the gear mounted at the shaft, expressed as acceleration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
VibrationAmplitudeAtTheGearMeshingFrequencyPerG |
|
Performance indicator of vibration calculated from the oscillation amplitude at the rotation frequency of the shaft, multiplied with the number of teeth of the gear mounted at the shaft, expressed as acceleration in units of the acceleration of gravity g. |
||
VibrationAmplitudeAtTheHarmonicsOfTheRotationFrequencyNx |
|
Performance indicator of vibration calculated from the oscillation amplitude at the harmonics of the rotation frequency of the object under consideration, expressed as velocity. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
VibrationAmplitudeAtTheRotationFrequency1X |
|
Oscillation amplitude at the rotation frequency of the object under consideration, expressed as velocity. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4403510 DisplayName: mm/s Description: millimetre per second |
|
||
VibrationAmplitudeAtTheSidebandsOfTheGearMeshingFrequency |
|
Root mean square of the oscillation signal within defined frequency ranges, which include the side bands of the mesh frequency above and below the mesh frequency, expressed as acceleration. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067595 DisplayName: m/s² Description: metre per second squared |
|
||
VibrationAmplitudeAtTheSidebandsOfTheGearMeshingFrequencyPerG |
|
Root mean square of the oscillation signal within defined frequency ranges, which include the side bands of the mesh frequency above and below the mesh frequency, expressed as acceleration in units of the acceleration of gravity g. |
The MultiPumpType provides Variables for Pump operation in a system with several Pumps and is formally defined in Table 76.
Table 76 – MultiPumpType Definition
Attribute |
Value |
||||
BrowseName |
MultiPumpType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
DistributionPriority |
0:String [] |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
DistributionType |
DistributionTypeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
ExchangeMode |
ExchangeModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
ExchangeTime |
0:DateTime |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
ExchangeTimeDifference |
0:Double |
0:AnalogUnitType |
O, RW |
0:HasComponent |
Variable |
MaximumNumberOfPumpsInOperation |
0:UInt32 |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
MultiPumpOperationMode |
MultiPumpOperationModeEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
NumberOfPumps |
0:UInt32 |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
PumpCollectiveIDs |
0:String [] |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
PumpRole |
PumpRoleEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
RedundantPumpIDs |
0:String [] |
0:DataItemType |
O, RW |
The optional Variables PumpCollectiveIDs, RedundantPumpIDs, and DistributionPriority are one dimensional arrays without a limit for possible entries.
The InstanceDeclarations of the MultiPumpType have additional Attributes defined in Table 77. The Variables and the associated Descriptions are based on the standard VDMA 24223.
Table 77 – MultiPumpType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
DistributionPriority |
|
This property describes in ascending order the priority of pumps in addition operation mode. |
||
DistributionType |
|
This property describes the share of operation time of different pumps of the pump system in addition operation mode. |
||
ExchangeMode |
|
This property specifies the exchange mode of the pump |
||
ExchangeTime |
|
This property specifies the determination of the absolute time for the next exchange of the pump, if operator specific Pump Exchange Mode is activated. |
||
ExchangeTimeDifference |
|
This property specifies the determination of the time for the next exchange of the pump relative to ExchangeTime, if operator specific Pump Exchange Mode is activated. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5457219 DisplayName: s Description: second [unit of time] |
|
||
MaximumNumberOfPumpsInOperation |
|
This property specifies the maximum number of pumps in operation. The difference between NumberOfPumps and MaximumNumberOfPumpsInOperation identifies the redundant pumps. |
||
MultiPumpOperationMode |
|
This property specifies the actual multi pump operation mode. In redundant operation mode a pump fulfils the process function of another pump. Addition operation mode characterizes the supplementary fulfilling of the process function. The mixed mode characterizes both operation tasks. |
||
NumberOfPumps |
|
This property identifies the number of pumps in multi pump management |
||
PumpCollectiveIDs |
|
This element identifies the pumps within the pump system |
||
PumpRole |
|
This property identifies the role rsp. task of the pump within the multi pump management. |
||
RedundantPumpIDs |
|
This property identifies the actual redundant pumps within the pump system |
The PortsGroupType provides Objects for the representation of Pump Ports, such as the inlet, outlet, and drive port. It is formally defined in Table 78.
Table 78 – PortsGroupType Definition
Attribute |
Value |
||||
BrowseName |
PortsGroupType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
<Drive> |
|
DrivePortType |
OP |
0:HasComponent |
Object |
<InletConnection> |
|
InletConnectionPortType |
OP |
0:HasComponent |
Object |
<OutletConnection> |
|
OutletConnectionPortType |
OP |
The InstanceDeclarations of the PortsGroupType have additional Attributes defined in Table 79.
Table 79 – PortsGroupType Attribute values for child Nodes
BrowsePath |
Description Attribute |
<Drive> |
Port for the connection of the drive. |
<InletConnection> |
Port for the inlet connection. |
<OutletConnection> |
Port for the outlet connection. |
The abstract PortType provides Variables for identification and specification of a Pump Port. It is illustrated in Figure 19 and formally defined in Table 80.
Figure 19 – Illustration of PortType
Table 80 – PortType Definition
Attribute |
Value |
||||
BrowseName |
PortType |
||||
IsAbstract |
True |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:BaseObjectType defined in OPC 10000-5. |
|||||
0:HasSubtype |
ObjectType |
DrivePortType |
Defined in 0 |
||
0:HasSubtype |
ObjectType |
InletConnectionPortType |
Defined in 7.38 |
||
0:HasSubtype |
ObjectType |
OutletConnectionPortType |
Defined in 0 |
||
|
|
|
|
|
|
0:HasComponent |
Variable |
Category |
0:String |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
Direction |
PortDirectionEnum |
0:DataItemType |
O, RW |
0:HasComponent |
Variable |
IdCarrier |
0:String |
0:DataItemType |
O, RW |
The InstanceDeclarations of the PortType have additional Attributes defined in Table 81. The Variables and the associated Descriptions are based on the AutomationML semantic.
Table 81 – PortType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Category |
The category property describes the Port type. The value of this attribute is user-defined. Only ports with the same category value are allowed to be connected. |
Direction |
Ports with the direction “In” can only be connected to ports with the direction “Out” or “InOut” and ports with the direction “Out” can only be connected with ports with the direction “In” or “InOut”. Ports with the direction “InOut” can be connected to Ports of arbitrary direction. |
IdCarrier |
This property contains the ID of the asset to which the port is assigned. |
The DrivePortType extends its supertype by FunctionalGroups for Pump drive specific Objects and Variables and is formally defined in Table 82.
Table 82 – DrivePortType Definition
Attribute |
Value |
||||
BrowseName |
DrivePortType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PortType defined in 7.36, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Design |
|
DriveDesignType |
O |
0:HasComponent |
Object |
Measurements |
|
DriveMeasurementsType |
O |
The InstanceDeclarations of the DrivePortType have additional Attributes defined in Table 83.
Table 83 – DrivePortType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Design |
Manufacturer's properties that describe the rudimentary data of the drive. |
Measurements |
All operation measurements that describe the drive. |
The InletConnectionPortType extends its supertype by FunctionalGroups for Pump inlet specific Objects and Variables and is formally defined in Table 84.
Table 84 – InletConnectionPortType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionPortType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PortType defined in 7.36, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Design |
|
InletConnectionDesignType |
O |
0:HasComponent |
Object |
Implementation |
|
InletConnectionImplementationType |
O |
0:HasComponent |
Object |
Measurements |
|
InletConnectionMeasurementsType |
O |
0:HasComponent |
Object |
SystemRequirements |
|
InletConnectionSystemRequirementsType |
O |
The InstanceDeclarations of the InletConnectionPortType have additional Attributes defined in Table 85.
Table 85 – InletConnectionPortType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Design |
Manufacturer's properties that describe the rudimentary data of the inlet connection. |
Implementation |
Properties that describe the specific installation and operational situation of the inlet connection. |
Measurements |
All measurements of the operation which describe the inlet connection. |
SystemRequirements |
Buyer's properties that describe the installation situation of the inlet port. |
The OutletConnectionPortType extends its supertype by FunctionalGroups for Pump outlet specific Objects and Variables and is formally defined in Table 86.
Table 86 – OutletConnectionPortType Definition
Attribute |
Value |
||||
BrowseName |
OutletConnectionPortType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PortType defined in 7.36, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Object |
Design |
|
OutletConnectionDesignType |
O |
0:HasComponent |
Object |
Implementation |
|
OutletConnectionImplementationType |
O |
0:HasComponent |
Object |
Measurements |
|
OutletConnectionMeasurementsType |
O |
0:HasComponent |
Object |
SystemRequirements |
|
OutletConnectionSystemRequirementsType |
O |
The InstanceDeclarations of the OutletConnectionPortType have additional Attributes defined in Table 87.
Table 87 – OutletConnectionPortType Attribute values for child Nodes
BrowsePath |
Description Attribute |
Design |
Manufacturer's properties that describe the rudimentary data of the outlet connection. |
Implementation |
Properties that describe the specific installation and operational situation of the outlet connection. |
Measurements |
All measurements of the operation which describe the outlet connection. |
SystemRequirements |
Buyer's properties that describe the installation situation of the outlet port. |
The abstract ConnectionDesignType provides static Variables for Pump inlet and outlet connection design properties. It is illustrated in Figure 20 and formally defined in Table 88.
Figure 20 – Illustration of ConnectionDesignType
Table 88 – ConnectionDesignType Definition
Attribute |
Value |
||||
BrowseName |
ConnectionDesignType |
||||
IsAbstract |
True |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasSubtype |
ObjectType |
InletConnectionDesignType |
Defined in 7.41 |
||
0:HasSubtype |
ObjectType |
OutletConnectionDesignType |
Defined in 7.42 |
||
|
|
|
|
|
|
0:HasComponent |
Variable |
NominalPressure |
0:String |
0:DataItemType |
O, RO |
The InstanceDeclarations of the ConnectionDesignType have additional Attributes defined in Table 89. The Variables and the associated Descriptions are based on the standard DIN EN 1333.
Table 89 – ConnectionDesignType Attribute values for child Nodes
BrowsePath |
Description Attribute |
NominalPressure |
Alphanumeric parameter for reference purposes, referring to a combination of mechanical and dimensional properties of a component of a piping system. It comprises the letters PN followed by a dimensionless number. |
The InletConnectionDesignType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 90.
Table 90 – InletConnectionDesignType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionDesignType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
CriticalBackingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
InletAreaOfThePump |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumAllowableInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumTolerableWaterVaporInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumWorkingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MinimumAllowableInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NetPositiveInletPressureRequired |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
WaterVaporCapacity |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the InletConnectionDesignType have additional Attributes defined in Table 91. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN 28426-1, ISO 3529-2 and ISO 21360-2.
Table 91 – InletConnectionDesignType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
CriticalBackingPressure |
|
Maximum backing pressure for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
InletAreaOfThePump |
|
Free cross-sectional area of the entry opening in the inlet connection of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067851 DisplayName: m² Description: square metre |
|
||
MaximumAllowableInletPressure |
|
Highest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumTolerableWaterVaporInletPressure |
|
The highest water vapor inlet pressure at which a gas ballast pump, under normal ambient conditions, can pump and exhaust pure water vapor in continuous Operation. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumWorkingPressure |
|
instantaneous inlet pressure with adequate margin above the minimum liquid vapor pressure expected. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MinimumAllowableInletPressure |
|
Lowest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
NetPositiveInletPressureRequired |
|
Total inlet pressure required to ensure there is enough margin to maintain the minimum. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
WaterVaporCapacity |
|
Mass of water which can be conveyed by the pump without condensation per time. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4600375 DisplayName: g/h Description: gram per hour |
|
The OutletConnectionDesignType extends its supertype by Pump outlet connection specific Variables and is formally defined in Table 92.
Table 92 – OutletConnectionDesignType Definition
Attribute |
Value |
||||
BrowseName |
OutletConnectionDesignType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
MaximumAllowableOutletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MinimumAllowableOutetPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OutletAreaOfThePump |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ReliefValveAccumulationPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ReliefValveBackPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ReliefValveReseatPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ReliefValveSetPressure |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the OutletConnectionDesignType have additional Attributes defined in Table 93. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
Table 93 – OutletConnectionDesignType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
MaximumAllowableOutletPressure |
|
Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MinimumAllowableOutetPressure |
|
Lowest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
OutletAreaOfThePump |
|
Free cross-sectional area of the orifice in the outlet connection of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067851 DisplayName: m² Description: square metre |
|
||
ReliefValveAccumulationPressure |
|
Outlet pressure at which the relief valve will pass the total pump flow. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
ReliefValveBackPressure |
|
Pressure at the outlet of the relief valve when the valve is closed. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
ReliefValveReseatPressure |
|
Outlet pressure at which the relief valve will close after passing the total pump flow. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
ReliefValveSetPressure |
|
Outlet pressure at which the relief valve begins to open. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
The DriveDesignType provides static Variables for Pump drive design properties and is formally defined in Table 94.
Table 94 – DriveDesignType Definition
Attribute |
Value |
||||
BrowseName |
DriveDesignType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
EnergyEfficiencyClassOfMotor |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
MaxNominalFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MinNominalFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MotorEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NominalFrequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NominalPowerConsumption |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NominalVoltage |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PowerFactor |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
ProtectionClass |
0:String |
0:DataItemType |
O, RO |
0:HasComponent |
Variable |
RatedCurrent |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
RatedSpeed |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
TorqueAtNominalSpeedOfDrive |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the DriveDesignType have additional Attributes defined in
Table 95. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1 and ECLASS entries.
Table 95 – DriveDesignType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
EnergyEfficiencyClassOfMotor |
|
Characterization of the energy efficiency of electric motors according to international standards. |
||
MaxNominalFrequency |
|
A suitable, maximum (usually rounded) value of a frequency to describe, designate or identify a component, device, resource, facility or equipment. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740186 DisplayName: Hz Description: hertz |
|
||
MinNominalFrequency |
|
A suitable minimum (usually rounded) value of a frequency to describe, designate or identify a component, device, resource, facility or equipment. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740186 DisplayName: Hz Description: hertz |
|
||
MotorEfficiency |
|
Proportion of the motor power input P_mot delivered as pump power input P_mot, u. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
NominalFrequency |
|
Design of the object at a certain frequency, which is repeated regularly. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740186 DisplayName: Hz Description: hertz |
|
||
NominalPowerConsumption |
|
Indication of the rated power consumption in watts. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
NominalVoltage |
|
Rated voltage is the value of the electrical voltage in normal operation specified by the manufacturer or supplier. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5655636 DisplayName: V Description: volt |
|
||
PowerFactor |
|
Ratio of the amount of active power to apparent power. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
ProtectionClass |
|
Protection class of an enclosure, expressed as NEMA or IP rating. |
||
RatedCurrent |
|
Appropriate (usually rounded) value of a current to describe, designate or identify a component, device, resource, facility or equipment. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4279632 DisplayName: A Description: ampere |
|
||
RatedSpeed |
|
Speed corresponding to the rated data of the motor used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4405559 DisplayName: s⁻¹ Description: reciprocal second |
|
||
TorqueAtNominalSpeedOfDrive |
|
The torque transmittable by the equipment. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5129559 DisplayName: N Description: newton |
|
The InletConnectionSystemRequirementsType provides static Variables for Pump inlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 96.
Table 96 – InletConnectionSystemRequirementsType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionSystemRequirementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
InletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the InletConnectionSystemRequirementsType have additional Attributes defined in Table 97. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.
Table 97 – InletConnectionSystemRequirementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
InletPressure |
|
Pressure at the inlet of the pump, measured at a defined location in the test dome. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
The OutletConnectionSystemRequirementsType provides static Variables for Pump outlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 98.
Table 98 – OutletConnectionSystemRequirementsType Definition
Attribute |
Value |
||||
BrowseName |
OutletConnectionSystemRequirementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
BackingPressure |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the OutletConnectionSystemRequirementsType have additional Attributes defined in Table 99. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.
Table 99 – OutletConnectionSystemRequirementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
BackingPressure |
|
Pressure at the outlet of a vacuum pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
The abstract ConnectionImplementationType provides static Variables for preconfiguring a Pump connection for the process in which the Pump is to be used. It is illustrated in Figure 21 and formally defined in Table 100.
Figure 21 – Illustration of ConnectionImplementationType
Table 100 – ConnectionImplementationType Definition
Attribute |
Value |
||||
BrowseName |
ConnectionImplementationType |
||||
IsAbstract |
True |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasSubtype |
ObjectType |
InletConnectionImplementationType |
Defined in 7.47 |
||
0:HasSubtype |
ObjectType |
OutletConnectionImplementationType |
Defined in 7.48 |
||
|
|
|
|
||
0:HasComponent |
Variable |
NominalSize |
0:String |
0:DataItemType |
O, RW |
The InstanceDeclarations of the ConnectionImplementationType have additional Attributes defined in Table 101. The Variables and the associated Descriptions are based on the standard ISO 6708.
Table 101 – ConnectionImplementationType Attribute values for child Nodes
BrowsePath |
Description Attribute |
NominalSize |
An alphanumeric designation of size for components of a pipework system, which is used for reference purposes. It comprises the letters DN followed by a dimensionless whole number which is indirectly related to the physical size, in millimeters, of the bore or outside diameter of the end connections. |
The InletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 102.
Table 102 – InletConnectionImplementationType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionImplementationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ConnectionImplementationType defined in 7.46, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
HeightOfTheInletConnection |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MeanRatedVelocityAtInlet |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedInletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
TotalHeadAtInletAreaOfThePump |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the InletConnectionImplementationType have additional Attributes defined in Table 103. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
Table 103 – InletConnectionImplementationType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
HeightOfTheInletConnection |
|
Height of the center of the inlet connection of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MeanRatedVelocityAtInlet |
|
Rated flow at pump inlet connection divided by the inlet area of the pump |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
RatedInletPressure |
|
Inlet pressure of the operating conditions at the guarantee point |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
TotalHeadAtInletAreaOfThePump |
|
Head observed at inlet area of the pump, corresponding to the sum of the height, pressure head and velocity head |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
The OutletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 104.
Table 104 – OutletConnectionImplementationType Definition
Attribute |
Value |
||||
BrowseName |
OutletConnectionImplementationType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ConnectionImplementationType defined in 7.46, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
HeightOfTheOutletConnection |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
MeanRatedVelocityAtOutlet |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
RatedOutletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
0:HasComponent |
Variable |
TotalHeadAtOutletAreaOfThePump |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the OutletConnectionImplementationType have additional Attributes defined in Table 105. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
Table 105 – OutletConnectionImplementationType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
HeightOfTheOutletConnection |
|
Height of the center of the outlet connection of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
||
MeanRatedVelocityAtOutlet |
|
Rated flow at pump outlet connection divided by the inlet area of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
RatedOutletPressure |
|
Outlet pressure of the pump at the guarantee point with rated flow and rated speed, as well as rated inlet pressure, for rotodynamic pumps only. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
TotalHeadAtOutletAreaOfThePump |
|
Head observed at outlet area of the pump, corresponding to the sum of the height, pressure head and velocity head. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre |
|
The DriveMeasurementsType provides Variables used for measurements performed at a Pump drive and is formally defined in Table 106. For the generation of events, the DriveMeasurementsType has a reference to the 0:LimitAlarmType. The InputNode Property of the Alarm shall contain the NodeId of the Component. Measurements defined in this ObjectType have an additional Subcomponent with the TypeDefinition 0:PropertyType and the BrowseName KindOfQuantity defined in Table 107. In this Variables the measurements can be matched to a physical quantity. To comply with this Companion Specification, the default values for the Property 0:EngineeringUnits and the Property KindOfQuantity provided in Table 108 should be used. The values should be sensible to the use of the application.
Table 106 – DriveMeasurementsType Definition
Attribute |
Value |
||||
BrowseName |
DriveMeasurementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
Current |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DCLinkCurrent |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DCLinkVoltage |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
DriverPowerInput |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
EnergyConsumption |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Frequency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MotorCurrent |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MotorEfficiency |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MotorTemperature |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MotorVoltage |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
PowerFactor |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Torque |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
Voltage |
0:Double |
0:BaseAnalogType |
O, RO |
0:GeneratesEvent |
ObjectType |
0:LimitAlarmType |
Defined in OPC 10000-9 |
Table 107 – DriveMeasurementsType Additional Subcomponents
Source Path |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Current |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
DCLinkCurrent |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
DCLinkVoltage |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
DriverPowerInput |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
EnergyConsumption |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Frequency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MotorCurrent |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MotorEfficiency |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MotorTemperature |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MotorVoltage |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
PowerFactor |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Torque |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
Voltage |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
The InstanceDeclarations of the DriveMeasurementsType have additional Attributes defined in Table 108. The Variables and the associated Descriptions are based on the standards VDMA 24223 and DIN EN ISO 17769-1.
Table 108 – DriveMeasurementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
Current |
|
Measured consumed mains current of the whole unit of the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4279632 DisplayName: A Description: ampere |
|
||
|
“electric current” |
Scalar quantity equal to the flux of the electric current density J through a given directed surface S |
||
DCLinkCurrent |
|
Measured actual electrical dc current of the converter. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4279632 DisplayName: A Description: ampere |
|
||
|
“electric current” |
Scalar quantity equal to the flux of the electric current density J through a given directed surface S |
||
DCLinkVoltage |
|
Measured actual electrical dc voltage of the converter. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5655636 DisplayName: V Description: volt |
|
||
|
“voltage” |
Scalar quantity equal to the line integral of the electric field strength E along a specific path linking two points a and b |
||
DriverPowerInput |
|
Measured power absorbed by the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5723220 DisplayName: W Description: watt |
|
||
|
“power” |
Derivative with respect to time t of energy E being transferred or transformed |
||
EnergyConsumption |
|
Measured energy consumption of the unit of the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4869973 DisplayName: J Description: joule |
|
||
|
“energy“ |
Ability of a system to do work |
||
Frequency |
|
Measured output frequency of the frequency converter. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4740186 DisplayName: Hz Description: hertz |
|
||
|
“frequency” |
Inverse of one cycle of a periodic event |
||
MotorCurrent |
|
Measured actual motor current. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4279632 DisplayName: A Description: ampere |
|
||
|
“electric current” |
Scalar quantity equal to the flux of the electric current density J through a given directed surface S |
||
MotorEfficiency |
|
Determined proportion of the motor power input P_mot delivered as pump power input P_mot, u |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description: percent |
|
||
|
“ratio” |
Quotient of two numbers or two quantities of the same kind |
||
MotorTemperature |
|
Measured temperature of the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
MotorVoltage |
|
Measured actual motor voltage. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5655636 DisplayName: V Description: volt |
|
||
|
“voltage” |
Scalar quantity equal to the line integral of the electric field strength E along a specific path linking two points a and b |
||
PowerFactor |
|
Determined power factor of the motor. |
||
|
“rational number” |
Element of a set of mathematical entities that includes all integers and other entities, each defined as the quotient of two integers, such that the division is defined for any two entities, except zero as a divisor |
||
Torque |
|
Measured torque of the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20053 DisplayName: N·m Description: newton metre |
|
||
|
“moment of force” |
Vector quantity described by the vector product M=r * F where r is position vector with respect to the axis of rotation and F is force |
||
Voltage |
|
Measured actual mains voltage of the motor. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5655636 DisplayName: V Description: volt |
|
||
|
“voltage” |
Scalar quantity equal to the line integral of the electric field strength E along a specific path linking two points a and b |
The InletConnectionMeasurementsType provides Variables used for measurements performed at a Pump inlet connection and is formally defined in Table 109. For the generation of events, the InletConnectionMeasurementsType has a reference to the 0:LimitAlarmType. The InputNode Property of the Alarm shall contain the NodeId of the Component. Measurements defined in this ObjectType have an additional Subcomponent with the TypeDefinition 0:PropertyType and the BrowseName KindOfQuantity defined in Table 110. In this Variables the measurements can be matched to a physical quantity. To comply with this Companion Specification, the default values for the Property 0:EngineeringUnits and the Property KindOfQuantity provided in Table 111 should be used. The values should be sensible to the use of the application.
Table 109 – InletConnectionMeasurementsType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionMeasurementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
InletTemperatureOfThePump |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MeanVelocityAtInlet |
0:Double |
0:BaseAnalogType |
O, RO |
0:GeneratesEvent |
ObjectType |
0:LimitAlarmType |
Defined in OPC 10000-9 |
Table 110 – InletConnectionMeasurementsType Additional Subcomponents
Source Path |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
InletTemperatureOfThePump |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
MeanVelocityAtInlet |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
The InstanceDeclarations of the InletConnectionMeasurementsType have additional Attributes defined in Table 111. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
Table 111 – InletConnectionMeasurementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
InletTemperatureOfThePump |
|
Measured temperature acting at the inlet area of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |
||
MeanVelocityAtInlet |
|
Measured rate of flow at pump inlet connection divided by the inlet area of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
|
“velocity” |
Vector quantity giving the rate of change of a position vector |
The OutletConnectionMeasurementsType provides Variables used for measurements performed at a Pump outlet connection and is formally defined in Table 112. For the generation of events, the OutletConnectionMeasurementsType has a reference to the 0:LimitAlarmType. The InputNode Property of the Alarm shall contain the NodeId of the Component. Measurements defined in this ObjectType have an additional Subcomponent with the TypeDefinition 0:PropertyType and the BrowseName KindOfQuantity defined in Table 113. In this Variables the measurements can be matched to a physical quantity. To comply with this Companion Specification, the default values for the Property 0:EngineeringUnits and the Property KindOfQuantity provided in Table 114 should be used. The values should be sensible to the use of the application.
Table 112 – OutletConnectionMeasurementsType Definition
Attribute |
Value |
||||
BrowseName |
OutletConnectionMeasurementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0: HasComponent |
Variable |
MeanVelocityAtOutlet |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
OutletTemperatureOfThePump |
0:Double |
0:BaseAnalogType |
O, RO |
0:GeneratesEvent |
ObjectType |
0:LimitAlarmType |
Defined in OPC 10000-9 |
Table 113 – OutletConnectionMeasurementsType Additional Subcomponents
Source Path |
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
MeanVelocityAtOutlet |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
OutletTemperatureOfThePump |
0:HasProperty |
Variable |
KindOfQuantity |
0:String |
0:PropertyType |
O, RO |
The InstanceDeclarations of the OutletConnectionMeasurementsType have additional Attributes defined in Table 114. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
Table 114 – OutletConnectionMeasurementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
MeanVelocityAtOutlet |
|
Measured rate of flow at pump outlet connection divided by the outlet area of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067859 DisplayName: m/s Description: metre per second |
|
||
|
“velocity” |
Vector quantity giving the rate of change of a position vector |
||
OutletTemperatureOfThePump |
|
Measured temperature acting at the outlet area of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin |
|
||
|
“temperature” |
Quantity representing a temperature value |