The InletConnectionDesignType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 90.
Table 90 – InletConnectionDesignType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionDesignType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
CriticalBackingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
InletAreaOfThePump |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumAllowableInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumTolerableWaterVaporInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MaximumWorkingPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
MinimumAllowableInletPressure |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
NetPositiveInletPressureRequired |
0:Double |
0:BaseAnalogType |
O, RO |
0:HasComponent |
Variable |
WaterVaporCapacity |
0:Double |
0:BaseAnalogType |
O, RO |
The InstanceDeclarations of the InletConnectionDesignType have additional Attributes defined in Table 91. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN 28426-1, ISO 3529-2 and ISO 21360-2.
Table 91 – InletConnectionDesignType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
CriticalBackingPressure |
|
Maximum backing pressure for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
InletAreaOfThePump |
|
Free cross-sectional area of the entry opening in the inlet connection of the pump. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067851 DisplayName: m² Description: square metre |
|
||
MaximumAllowableInletPressure |
|
Highest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumTolerableWaterVaporInletPressure |
|
The highest water vapor inlet pressure at which a gas ballast pump, under normal ambient conditions, can pump and exhaust pure water vapor in continuous Operation. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MaximumWorkingPressure |
|
instantaneous inlet pressure with adequate margin above the minimum liquid vapor pressure expected. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
MinimumAllowableInletPressure |
|
Lowest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
NetPositiveInletPressureRequired |
|
Total inlet pressure required to ensure there is enough margin to maintain the minimum. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|
||
WaterVaporCapacity |
|
Mass of water which can be conveyed by the pump without condensation per time. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4600375 DisplayName: g/h Description: gram per hour |
|