The InletConnectionDesignType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 90.

Table 90 – InletConnectionDesignType Definition

Attribute

Value

BrowseName

InletConnectionDesignType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

CriticalBackingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

InletAreaOfThePump

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableInletPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumTolerableWaterVaporInletPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumWorkingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableInletPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

NetPositiveInletPressureRequired

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

WaterVaporCapacity

0:Double

0:BaseAnalogType

O, RO

The InstanceDeclarations of the InletConnectionDesignType have additional Attributes defined in Table 91. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN 28426-1, ISO 3529-2 and ISO 21360-2.

Table 91 – InletConnectionDesignType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

CriticalBackingPressure

Maximum backing pressure for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump.

CriticalBackingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

InletAreaOfThePump

Free cross-sectional area of the entry opening in the inlet connection of the pump.

InletAreaOfThePump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067851

DisplayName: m²

Description: square metre

MaximumAllowableInletPressure

Highest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

MaximumAllowableInletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumTolerableWaterVaporInletPressure

The highest water vapor inlet pressure at which a gas ballast pump, under normal ambient conditions, can pump and exhaust pure water vapor in continuous Operation.

MaximumTolerableWaterVaporInletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumWorkingPressure

instantaneous inlet pressure with adequate margin above the minimum liquid vapor pressure expected.

MaximumWorkingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MinimumAllowableInletPressure

Lowest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

MinimumAllowableInletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

NetPositiveInletPressureRequired

Total inlet pressure required to ensure there is enough margin to maintain the minimum.

NetPositiveInletPressureRequired

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

WaterVaporCapacity

Mass of water which can be conveyed by the pump without condensation per time.

WaterVaporCapacity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4600375

DisplayName: g/h

Description: gram per hour