The structure PhysicalAddressDataType defines parameters for the physical address of the manufacturer in Table 115.

Table 115 – PhysicalAddressDataType Structure

Name

Type

Description

PhysicalAddressDataType

structure

Subtype of 0:Structure defined in OPC 10000-5.

Street

0:LocalizedText

Street name where the manufacturer is located.

Number

0:LocalizedText

Street number where the manufacturer is located.

City

0:LocalizedText

City where the manufacturer is located.

PostalCode

0:LocalizedText

Postal code where the manufacturer is located.

State

0:LocalizedText

State where the manufacturer is located.

Country

0:LocalizedText

Country where the manufacturer is located.

The DeclarationOfConformityOptionSet defines flags for directives on the basis of which conformity was determined in Table 116.

Table 116 – DeclarationOfConformityOptionSet Values

Value

Bit No.

Description

2006_42_EC

0

Directives of the EU Declaration of Conformity - 2006/ 42/ EG, concerning machinery and amending Directive 95/16/EG

2009_125_EC

1

Directives of the EU Declaration of Conformity - 2009/ 125/ EC, establishing a framework for the setting of ecodesign requirements for energy-related products

2011_65_EU

2

Directives of the EU Declaration of Conformity - 2011/ 65/ EU, restriction of the use of certain hazardous substances in electrical and electronic equipment

2014_35_EU

3

Directives of the EU Declaration of Conformity - 2014/ 35/ EU, harmonization of the laws of the Member States on the provision of electrical equipment for use within certain voltage limits on the market

2014_34_EU

4

Directives of the SEU Declaration of Conformity - 2014/ 34/ EU, harmonization of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres

2014_30_EU

5

Directives of the EU Declaration of Conformity - 2014/ 30/ EU, harmonization of the laws of the Member States on electromagnetic compatibility

2014_68_EU

6

Directives of the EU Declaration of Conformity - 2014/ 68/ EU, harmonization of Member States' legislation on the provision of pressure equipment on the market

2014_29_EU

7

Directives of the EU Declaration of Conformity - 2014/ 29/ EU, harmonization of the laws of the Member States relating to the making available on the market of simple pressure vessels

The DeclarationOfConformityOptionSet representation in the AddressSpace is formally defined in Table 117.

Table 117 – DeclarationOfConformityOptionSet Definition

Attribute

Value

BrowseName

DeclarationOfConformityOptionSet

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the OptionSet DataType defined in OPC 10000-5

0:HasProperty

Variable

OptionSetValues

0:LocalizedText[]

0:PropertyType

M, RO

The ExplosionProtectionOptionSet defines flags for the category of explosion protection for devices according to EU Directive 2014/34/EU (ATEX) in Table 118.

Table 118 – ExplosionProtectionOptionSet Values

Value

Bit No.

Description

M1

0

This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)

M2

1

This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)

1G

2

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)

2G

3

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)

3G

4

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU)

1D

5

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)

2D

6

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)

3D

7

Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU)

The ExplosionProtectionOptionSet representation in the AddressSpace is formally defined in Table 119.

Table 119 – ExplosionProtectionOptionSet Definition

Attribute

Value

BrowseName

ExplosionProtectionOptionSet

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the OptionSet DataType defined in OPC 10000-5

0:HasProperty

Variable

OptionSetValues

0:LocalizedText[]

0:PropertyType

M, RO

The ExplosionZoneOptionSet defines flags for the category of explosion zones for Pumps according to definitions from the hazardous substances ordinance (GefStoffV) in Table 120.

Table 120 – ExplosionZoneOptionSet Values

Value

Bit No.

Description

Zone 0

0

A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is present continuously or for long periods or frequently.

Zone 1

1

A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally.

Zone 2

2

A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Zone 20

3

A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, for long periods or frequently.

Zone 21

4

A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally.

Zone 22

5

A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

The ExplosionZoneOptionSet representation in the AddressSpace is formally defined in Table 121.

Table 121 – ExplosionZoneOptionSet Definition

Attribute

Value

BrowseName

ExplosionZoneOptionSet

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the OptionSet DataType defined in OPC 10000-5

0:HasProperty

Variable

OptionSetValues

0:LocalizedText[]

0:PropertyType

M, RO

The OfferedControlModesOptionSet defines flags for offered control modes supported by the manufacturer of a Pump in Table 122. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 122 – OfferedControlModesOptionSet Values

Value

Bit No.

Description

Constant pressure control

0

Constant pressure control mode

Constant temperature control

1

Constant temperature control mode

Differential pressure control

2

Differential pressure control mode

Constant differential pressure control

3

Constant differential pressure control mode

Variable differential pressure control

4

Variable differential pressure control mode

Flow_dependent differential pressure control

5

Flow-dependent differential pressure control mode

Return flow temperature control

6

Return flow temperature control mode

Flow temperature control

7

Flow temperature control mode

Flow rate control

8

Flow rate control mode

Automatic

9

Automatic control mode

Uncontrolled

10

None / uncontrolled mode

Speed control

11

Speed control mode

The OfferedControlModesOptionSet representation in the AddressSpace is formally defined in Table 123.

Table 123 – OfferedControlModesOptionSet Definition

Attribute

Value

BrowseName

OfferedControlModesOptionSet

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the OptionSet DataType defined in OPC 10000-5

0:HasProperty

Variable

OptionSetValues

0:LocalizedText[]

0:PropertyType

M, RO

The OfferedFieldbusesOptionSet defines flags for fieldbuses supported by the manufacturer of a Pump in Table 124.

Table 124 – OfferedFieldbusesOptionSet Values

Value

Bit No.

Description

Other

0

Additional fieldbuses listed in the AdditionalFieldbuses variable

ARCNET

1

ARCNET

AS_Interface

2

AS-Interface

BACnet_IP

3

BACnet/IP

BACnet_MSTP

4

BACnet/MSTP

Bluetooth

5

Bluetooth

Bluetooth Low Energy

6

Bluetooth Low Energy

CAN

7

CAN

CANopen

8

CANopen

CC_Link

9

CC-Link

ControlNet

10

ControlNet

DALI

11

DALI

DECT ULE

12

DECT ULE

DeviceNet

13

DeviceNet

DMX

14

DMX

KNX

15

KNX

EnOcean

16

EnOcean

EtherCAT

17

EtherCAT

Ethernet_IP

18

Ethernet/IP

Ethernet TCP_IP

19

Ethernet TCP/IP

IEEE1588

20

IEEE1588

GSM

21

GSM

Interbus

22

Interbus

IO_Link

23

IO-Link

HART

24

HART

LON

25

LON

LoRaWAN

26

LoRaWAN

LIN_Bus

27

LIN-Bus

LTE

28

LTE

LTE_M

29

LTE-M

M_Bus

30

M-Bus

Modbus TCP

31

Modbus TCP

Modbus RTU

32

Modbus RTU

MP_Bus

33

MP-Bus

NB_IOT

34

NB-IOT

NFC

35

NFC

OPC UA

36

OPC UA

OPC DA

37

OPC DA

PROFIBUS DP

38

PROFIBUS DP

PROFINET RT

39

PROFINET RT

Powerlink

40

Powerlink

SERCOS

41

SERCOS

SMI

42

SMI

Thread

43

Thread

UMTS

44

UMTS

WIFI

45

WIFI

X2X_Link

46

X2X-Link

VARAN

47

VARAN

ZigBee

48

ZigBee

Z_Wave

49

Z-Wave

Other on Bit 0 is used to indicate that the manufacturer has added specific fieldbuses in the AdditionalFieldbuses Variable.

The OfferedFieldbusesOptionSet representation in the AddressSpace is formally defined in Table 125.

Table 125 – OfferedFieldbusesOptionSet Definition

Attribute

Value

BrowseName

OfferedFieldbusesOptionSet

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

Other

Subtype of the OptionSet DataType defined in OPC 10000-5

0:HasProperty

Variable

OptionSetValues

0:LocalizedText[]

0:PropertyType

M, RO

The enumeration ControlModeEnum defines possible Pump control modes in Table 126.

Table 126 – ControlModeEnum Items

Name

Value

Description

ConstantPressureControl

0

Constant pressure control mode

ConstantTemperatureControl

1

Constant temperature control mode

DifferentialPressureControl

2

Differential pressure control mode

ConstantDifferentialPressureControl

3

Constant differential pressure control mode

VariableDifferentialPressureControl

4

Variable differential pressure control mode

FlowDependentDifferentialPressureControl

5

Flow-dependent differential pressure control mode

ReturnFlowTemperatureControl

6

Return flow temperature control mode

FlowTemperatureControl

7

Flow temperature control mode

FlowRateControl

8

Flow rate control mode

SpeedControl

9

Speed control mode

Automatic

10

Automatic control mode

Uncontrolled

11

None / uncontrolled mode

The ControlModeEnum representation in the AddressSpace is formally defined in Table 127.

Table 127 – ControlModeEnum Definition

Attribute

Value

BrowseName

ControlModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration PumpClassEnum defines possible Pump PumpClasss in Table 128.

Table 128 – PumpClassEnum Items

Name

Value

Description

RotodynamicPump

0

Rotodynamic pump

PositiveDisplacementPump

1

Positive displacement pump

ProcessVacuumPump

2

Process vacuum pump

TurboVacuumPump

3

Turbo vacuum pump

VacuumPump

4

Vacuum pump

LiquidPump

5

Liquid pump

Pump

6

Pump

The PumpClassEnum representation in the AddressSpace is formally defined in Table 129.

Table 129 – PumpClassEnum Definition

Attribute

Value

BrowseName

PumpClassEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration DistributionTypeEnum defines possible Pump distributions in Table 130. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 130 – DistributionTypeEnum Items

Name

Value

Description

ManufacturerSpecific

0

Manufacturer specific distribution of operation time

OperatorSpecific

1

Operator specific distribution of operation time

ConcerningTimeDistribution

2

Equivalent distribution of operation time, concerning time distribution

ConcerningLoadDistribution

3

Equivalent distribution of operation time, concerning load distribution

The DistributionTypeEnum representation in the AddressSpace is formally defined in Table 131.

Table 131 – DistributionTypeEnum Definition

Attribute

Value

BrowseName

DistributionTypeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration ExchangeModeEnum defines possible Pump exchange modes in Table 132. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 132 – ExchangeModeEnum Items

Name

Value

Description

ManufacturerSpecific

0

Manufacturer specific pump exchange mode

ExchangeDisabled

1

Pump exchange disabled

OperatorSpecific

2

Operator specific pump exchange mode

The ExchangeModeEnum representation in the AddressSpace is formally defined in Table 133.

Table 133 – ExchangeModeEnum Definition

Attribute

Value

BrowseName

ExchangeModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 0:Enumeration type defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration FieldbusEnum defines possible Pump fieldbuses in Table 134.

Table 134 – FieldbusEnum Items

Name

Value

Description

Other

0

Fieldbus is not specified in this enumeration

ARCNET

1

ARCNET

AS-Interface

2

AS-Interface

BACnet/IP

3

BACnet/IP

BACnet/MSTP

4

BACnet/MSTP

Bluetooth

5

Bluetooth

BluetoothLowEnergy

6

Bluetooth Low Energy

CAN

7

CAN

CANopen

8

CANopen

CC-Link

9

CC-Link

ControlNet

10

ControlNet

DALI

11

DALI

DECTULE

12

DECT ULE

DeviceNet

13

DeviceNet

DMX

14

DMX

KNX

15

KNX

EnOcean

16

EnOcean

EtherCAT

17

EtherCAT

Ethernet/IP

18

Ethernet/IP

EthernetTCP/IP

19

Ethernet TCP/IP

IEEE1588

20

IEEE1588

GSM

21

GSM

Interbus

22

Interbus

IO-Link

23

IO-Link

HART

24

HART

LON

25

LON

LoRaWAN

26

LoRaWAN

LIN-Bus

27

LIN-Bus

LTE

28

LTE

LTE-M

29

LTE-M

M-Bus

30

M-Bus

ModbusTCP

31

Modbus TCP

ModbusRTU

32

Modbus RTU

MP-Bus

33

MP-Bus

NB-IOT

34

NB-IOT

NFC

35

NFC

OPCUA

36

OPC UA

OPCDA

37

OPC DA

PROFIBUSDP

38

PROFIBUS DP

PROFINETRT

39

PROFINET RT

Powerlink

40

Powerlink

SERCOS

41

SERCOS

SMI

42

SMI

Thread

43

Thread

UMTS

44

UMTS

WIFI

45

WIFI

X2X-Link

46

X2X-Link

VARAN

47

VARAN

ZigBee

48

ZigBee

Z-Wave

49

Z-Wave

Manufacturer specific on Value 0 is used to indicate that a manufacturer specific fieldbus is needed.

The FieldbusEnum representation in the AddressSpace is formally defined in Table 135.

Table 135 – FieldbusEnum Definition

Attribute

Value

BrowseName

FieldbusEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration MaintenanceLevelEnum defines possible Pump maintenance levels in Table 136. The Values and the associated Descriptions are based on the standard DIN EN 13306.

Table 136 – MaintenanceLevelEnum Items

Name

Value

Description

Level1

0

Level 1 is characterized by simple actions carried out with minimal training

Level2

1

Level 2 is characterized by basic actions which have to be carried out by qualified personnel using detailed procedures

Level3

2

Level 3 is characterized by complex actions carried out by qualified technical personnel using detailed procedures

Level4

3

Level 4 is characterized by actions which imply the know-how of a technique or a technology and carried out by specialized technical personnel

Level5

4

Level 5 is characterized by actions which imply a knowledge held by the manufacturer or a specialized company with industrial logistic support equipment

The MaintenanceLevelEnum representation in the AddressSpace is formally defined in Table 137.

Table 137 – MaintenanceLevelEnum Definition

Attribute

Value

BrowseName

MaintenanceLevelEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration MultiPumpOperationModeEnum defines possible multi Pump operation modes in Table 138. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 138 – MultiPumpOperationModeEnum Items

Name

Value

Description

Standalone

0

Standalone mode

RedundancyOperation

1

pump fulfils the process function of another pump

AdditionOperation

2

supplementary fulfilling of the process function

MixedRedundancy

3

Redundancy and addition operation mixed

The MultiPumpOperationModeEnum representation in the AddressSpace is formally defined in Table 139.

Table 139 – MultiPumpOperationModeEnum Definition

Attribute

Value

BrowseName

MultiPumpOperationModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration OperatingModeEnum Pump operating modes in Table 140.

Table 140 – OperatingModeEnum Items

Name

Value

Description

SingleOperation

0

Single operating mode

SeriesOperation

1

Series operating mode

ParallelOperation

2

Parallel operating mode

The OperatingModeEnum representation in the AddressSpace is formally defined in Table 141.

Table 141 – OperatingModeEnum Definition

Attribute

Value

BrowseName

OperatingModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration OperationModeEnum defines possible Pump operation modes in Table 142. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 142 – OperationModeEnum Items

Name

Value

Description

AutoControl

0

standard control algorithm, not configurable

ClosedLoopStandardPID

1

pid algorithm, control parameters configurable in functional element ControlPID

Advanced

2

manufacturer specific control algorithm, control parameters configurable

StandBy

3

ready for operation

OpenLoopMin

4

open loop operation at minimum characteristic

OpenLoopValue

5

open loop operation at set point value

OpenLoopMax

6

open loop operation at maximum characteristic

ClosedLoopMin

7

closed loop operation at minimum characteristic

ClosedLoopMax

8

closed loop operation at maximum characteristic

Test

9

Test operation

Calibration

10

Calibration mode

The OperationModeEnum representation in the AddressSpace is formally defined in Table 143.

Table 143 – OperationModeEnum Definition

Attribute

Value

BrowseName

OperationModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration PortDirectionEnum defines possible Port directions in Table 144. The Values and the associated Descriptions are based on the AutomationML semantic.

Table 144 – PortDirectionEnum Items

Name

Value

Description

In

0

Ports with the direction “In” can only be connected to ports with the direction “Out” or “InOut”.

Out

1

Ports with the direction “Out” can only be connected to ports with the direction “In” or “InOut”.

InOut

2

Ports with the direction “InOut” can be connected to ports with arbitrary directions.

The PortDirectionEnum representation in the AddressSpace is formally defined in Table 145.

Table 145 – PortDirectionEnum Definition

Attribute

Value

BrowseName

PortDirectionEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration PumpKickModeEnum defines possible Pump kick modes in Table 146. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 146 – PumpKickModeEnum Items

Name

Value

Description

ManufacturerSpecific

0

Manufacturer specific pump kick mode

Disabled

1

Pump kick mode disabled

OperatorSpecific

2

Operator specific pump kick mode

The PumpKickModeEnum representation in the AddressSpace is formally defined in Table 147.

Table 147 – PumpKickModeEnum Definition

Attribute

Value

BrowseName

PumpKickModeEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration PumpRoleEnum defines possible Pump roles in Table 148. The Values and the associated Descriptions are based on the standard VDMA 24223.

Table 148 – PumpRoleEnum Items

Name

Value

Description

Slave

0

Slave

Master

1

Master

SlaveAndAuxiliaryMaster

2

Slave and auxiliary master

The PumpRoleEnum representation in the AddressSpace is formally defined in Table 149.

Table 149 – PumpRoleEnum Definition

Attribute

Value

BrowseName

PumpRoleEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType

The enumeration StateOfTheItemEnum defines possible Pump states in Table 150. The Values and the associated Descriptions are based on the standard DIN EN 13306.

Table 150 – StateOfTheItemEnum Items

Name

Value

Description

IdleState

0

Item is in up state and non-operating outside required time

StandByState

1

Item is in up state and non-operating during required time

OperatingState

2

Item is in up state and operating as required

ExternalDisabledState

3

Item is in up state, but lacks required external resources or is disabled due to planned actions other than maintenance

DownState

4

Item is unable to perform a required function due to preventive maintenance or a fault

The StateOfTheItemEnum representation in the AddressSpace is formally defined in Table 151.

Table 151 – StateOfTheItemEnum Definition

Attribute

Value

BrowseName

StateOfTheItemEnum

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:Enumeration defined in OPC 10000-5.

0:HasProperty

Variable

0:EnumValues

0:EnumValueType[]

0:PropertyType