The DesignType provides static Variables for design properties, describing the limitations and working conditions of a Pump and is formally defined in Table 47.

Table 47 – DesignType Definition

Attribute

Value

BrowseName

DesignType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

AdditionalFieldbuses

0:String [128]

0:DataItemType

O, RO

0:HasComponent

Variable

BalancingRateOfFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

BasePressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ClearanceVolume

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ClockwiseRotation

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Controllable

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Cool_DownTimeForAVaporJetPumpOrADiffusionPump

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

Counter_ClockwiseRotation

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

CriticalSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

DeclarationOfConformity

0:String

0:DataItemType

O, RO

0:HasComponent

Variable

DeclarationOfConformityAvailable

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

DesignAxialLoad

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

DesignRadialLoad

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

DirectivesOfEUDeclarationOfConformity

DeclarationOfConformityOptionSet

0:DataItemType

O, RO

0:HasComponent

Variable

DryCriticalSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ExplosionProtection

ExplosionProtectionOptionSet

0:DataItemType

O, RO

0:HasComponent

Variable

GeometricalFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

GeometricDisplacementVolume

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

HeadAtPeakPoint

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Object

InstallationNpshCurve

0:FileType

O

0:HasComponent

Variable

LeakageRateOfFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableAmbientTemperature

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableCasingWorkingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableContinuousSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableHead

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableRelativeHumidity

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableTemperature

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableThroughput

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAllowableWorkingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumAxialLoad

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumPumpPowerInput

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumRadialLoad

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MaximumStaticSealingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MeanTimebetweenFailures

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableAmbientTemperature

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableContinuousSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableHead

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableRelativeHumidity

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableTemperature

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableThermalFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumContinuousStableFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumContinuousThermalFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

NetPositiveSuctionHeadRequired

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

NetPositiveSuctionHeadRequiredForADropOf3Percent

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

OfferedControlModes

OfferedControlModesOptionSet

0:DataItemType

O, RO

0:HasComponent

Variable

OfferedFieldbuses

OfferedFieldbusesOptionSet

0:DataItemType

O, RO

0:HasComponent

Variable

OptimumHead

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

OptimumPumpPowerInput

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

OptimumRateOfFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

PistonVelocity

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

PossibleFluids

0:String []

0:DataItemType

O, RO

0:HasComponent

Variable

Pre_ChargePressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

PumpClass

PumpClassEnum

0:DataItemType

O, RO

0:HasComponent

Object

PumpCurve

0:FileType

O

0:HasComponent

Object

PumpEfficiencyCurve

0:FileType

O

0:HasComponent

Object

PumpH_Q_Curve

0:FileType

O

0:HasComponent

Object

PumpNpshCurve

0:FileType

O

0:HasComponent

Object

PumpPowerInputCurve

0:FileType

O

0:HasComponent

Variable

Shut_OffHead

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

Shut_OffPumpPowerInput

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SlipFlow

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundEnergy

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundEnergyLevel

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundPower

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundPowerLevel

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SoundPressureLevel

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SpecificSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Object

StablePumpH_Q_Curve

0:FileType

O

0:HasComponent

Variable

StandardGasFlowrate

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

StartingPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

Suction_SpecificSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

SweptVolume

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

TripSpeed

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

TypeNumber

0:Double

0:DataItemType

O, RO

0:HasComponent

Variable

VolumeFlowRate

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

VolumeFlowRateOfBackingPump

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

WarmUpTimeForAVaporJetPumpOrADiffusionPump

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

WaterVaporTolerableLoad

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

WetCriticalSpeed

0:Double

0:BaseAnalogType

O, RO

The optional Variable AdditionalFieldbuses is a one dimensional array with a limit of 128 entries.

The optional Variable PossibleFluids is a one dimensional array without a limit for possible entries.

The InstanceDeclarations of the DesignType have additional Attributes defined in Table 48. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN EN ISO 17769-2, DIN ISO 21360-1, ISO 3529-2, DIN 28400-2, DIN EN ISO 80000-8, ISO/TR 25417 and DIN EN 13306.

Table 48 – DesignType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

AdditionalFieldbuses

Additional fieldbuses supported by the product.

BalancingRateOfFlow

Rate of flow which is extracted to activate a balance device

BalancingRateOfFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

BasePressure

Pressure obtained in the test dome after conditioning the vacuum pump and the test dome

BasePressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

ClearanceVolume

Volume remaining unswept at the end of the discharge stroke.

ClearanceVolume

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

ClockwiseRotation

Direction of rotation in which the shaft is seen to be turning in a clockwise direction when viewing the drive end of the shaft. A "True" status means that the rotation of pump is clockwise and a "False" status means that the rotation of pump is anticlockwise.

Controllable

Indicates whether the product is a controllable pump or a self-controlling pump. A "True" status means that the pump is controllable and a "False" status means that the pump is not controllable.

Cool_DownTimeForAVaporJetPumpOrADiffusionPump

The cool-down time is the time required to cool the propellant from the working temperature to a temperature at which the propellant can be exposed to atmospheric air without risk after the heating has been switched off.

Cool_DownTimeForAVaporJetPumpOrADiffusionPump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5457219

DisplayName: s

Description: second [unit of time]

Counter_ClockwiseRotation

Direction of rotation in which the shaft is seen to be turning in an anticlockwise direction, when viewing the drive end of the shaft. A "True" status means that the rotation of pump is anticlockwise and a "False" status means that the rotation of pump is clockwise.

CriticalSpeed

Speed of rotation at which the frequency of vibration (or its multiples) corresponds to the rotor resonant (lateral or torsional)

CriticalSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

DeclarationOfConformity

Publicly accessible attestation of conformity, commonly available on websites.

DeclarationOfConformityAvailable

Whether or not a declaration of conformity exists. A "True" status means that the declaration exists and a "False" status means that there is no declaration available.

DesignAxialLoad

Residual axial thrust on the pump rotor on which the thrust-bearing selection is based.

DesignAxialLoad

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

DesignRadialLoad

Radial load of the pump rotor for which the bearing system is selected.

DesignRadialLoad

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

DirectivesOfEUDeclarationOfConformity

Set of directives on the basis of which conformity was determined.

DryCriticalSpeed

Rotor resonant frequency calculated assuming that the rotor is supported only at its bearings and that the bearings are of infinite stiffness

DryCriticalSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

ExplosionProtection

Device category for explosion protection according to 2014/34/EU (ATEX).

GeometricalFlow

Product of geometrical displacement volume and speed of rotation or stroke frequency

GeometricalFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

GeometricDisplacementVolume

Displacement volume for one stroke or one cycle.

GeometricDisplacementVolume

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

HeadAtPeakPoint

Highest total head developed by a pump when this does not occur at a zero rate of flow

HeadAtPeakPoint

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

InstallationNpshCurve

Relationship between the net positive suction head available and the rate of flow at given operating conditions for a given liquid

LeakageRateOfFlow

Rate of flow leaking from shaft seals

LeakageRateOfFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MaximumAllowableAmbientTemperature

Highest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable

MaximumAllowableAmbientTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MaximumAllowableCasingWorkingPressure

Greatest outlet pressure at the specified operating temperature at which the pump casing can be used

MaximumAllowableCasingWorkingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumAllowableContinuousSpeed

Highest rotational speed for continuous operation recommended by the manufacturer

MaximumAllowableContinuousSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

MaximumAllowableHead

Maximum permissible head at which the pump can be continuously operated without suffering damage

MaximumAllowableHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MaximumAllowableRelativeHumidity

Highest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable

MaximumAllowableRelativeHumidity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MaximumAllowableTemperature

Highest allowable continuous fluid temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure

MaximumAllowableTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MaximumAllowableThroughput

Maximum pV flow the pump can withstand without damage

MaximumAllowableThroughput

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4665393

DisplayName: Pa·m³/s

Description: pascal cubic metre per second

MaximumAllowableWorkingPressure

Pressure for a component on the basis of materials used and on the basis of calculation rules at the specified operating temperature

MaximumAllowableWorkingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumAxialLoad

Greatest value of the residual axial thrust on the pump rotor resulting from operating the pump at any condition within its allowable operating range.

MaximumAxialLoad

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

MaximumPumpPowerInput

Highest value of the pump power input at any rate of flow at any allowable operating condition

MaximumPumpPowerInput

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

MaximumRadialLoad

Greatest radial load of the pump rotor resulting from operating the pump at any condition within its allowable operating range.

MaximumRadialLoad

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

MaximumStaticSealingPressure

Highest pressure, excluding hydrostatic testing, to which the seal can be subjected while the pump is shut down

MaximumStaticSealingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MeanTimebetweenFailures

Average of the times between failures.

MeanTimebetweenFailures

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4740434

DisplayName: h

Description: hour

MinimumAllowableAmbientTemperature

Lowest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable

MinimumAllowableAmbientTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MinimumAllowableContinuousSpeed

Lowest speed for continuous operation recommended by the manufacturer

MinimumAllowableContinuousSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

MinimumAllowableHead

Minimum permissible head at which the pump can be operated without suffering damage

MinimumAllowableHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MinimumAllowableRelativeHumidity

Lowest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable

MinimumAllowableRelativeHumidity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MinimumAllowableTemperature

Lowest allowable continuous temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure

MinimumAllowableTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MinimumAllowableThermalFlow

Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid

MinimumAllowableThermalFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumContinuousStableFlow

Lowest flow at which the pump can be operated without it adversely affecting its performance in terms of life expectancy, noise and vibrations

MinimumContinuousStableFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumContinuousThermalFlow

Lowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid

MinimumContinuousThermalFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

NetPositiveSuctionHeadRequired

Minimum NPSH at the pump inlet connection required to give the rated or operating performance at the specified conditions

NetPositiveSuctionHeadRequired

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

NetPositiveSuctionHeadRequiredForADropOf3Percent

NPSH required for a drop of 3 % in the total head of the first stage of the pump as a standard basis for use in performance curves

NetPositiveSuctionHeadRequiredForADropOf3Percent

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OfferedControlModes

Control modes supported by the manufacturer for the product.

OfferedFieldbuses

Fieldbuses supported by the manufacturer for the product.

OptimumHead

Total head developed by the pump at a rate of flow corresponding to the best efficiency

OptimumHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OptimumPumpPowerInput

Pump power input at the rate of flow corresponding to the best efficiency

OptimumPumpPowerInput

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

OptimumRateOfFlow

Rate of flow at the point of best efficiency

OptimumRateOfFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

PistonVelocity

Average speed given by the stroke length multiplied with the number of complete pumping cycles of the piston, plunger or piston attached to the diaphragm per minute (stroke per minute or pump crank speed)

PistonVelocity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

PossibleFluids

Fluids that can be pumped by the pump.

Pre_ChargePressure

Pressure to which the pulsation dampener is charged with dry gas prior to start of operation

Pre_ChargePressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

PumpClass

Pump type according to functional principle and pumped fluid

PumpCurve

Representation of the pump head plotted against the flow rate

PumpEfficiencyCurve

Relationship between the pump efficiency and the rate of flow at given operating conditions of speed and liquid

PumpH_Q_Curve

Relationship between the total head of the pump and the rate of flow at given operating conditions /rated conditions of speed and liquid

PumpNpshCurve

Relationship between the net positive suction head required and the rate of flow at given operating conditions of speed and liquid

PumpPowerInputCurve

Relationship between the pump power input and the rate of flow given operating conditions of speed and liquid

Shut_OffHead

Total head developed by the pump in a zero rate of flow

Shut_OffHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

Shut_OffPumpPowerInput

Pump power input at zero rate of flow

Shut_OffPumpPowerInput

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

SlipFlow

Flow lost internally through clearances

SlipFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

SoundEnergy

Integral of the sound power, P, over a stated time interval of duration T (starting at t1 and ending at t2).

SoundEnergy

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4869973

DisplayName: J

Description: joule

SoundEnergyLevel

Ten times the logarithm to the base 10 of the ratio of the sound energy, J, to a reference value, J0, expressed in decibels.

SoundEnergyLevel

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SoundPower

Through a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface.

SoundPower

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

SoundPowerLevel

Ten times the logarithm to the base 10 of the ratio of the sound power of a source, P, to a reference value, P0, expressed in decibels.

SoundPowerLevel

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SoundPressure

Difference between instantaneous pressure and static pressure.

SoundPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

SoundPressureLevel

Ten times the logarithm to the base 10 of the ratio of the square of the sound pressure, p, to the square of a reference value, p0, expressed in decibels.

SoundPressureLevel

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SpecificSpeed

Speed that characterizes a pump in terms of its speed, flow rate per impeller eye, i.e. total flow for single-flow impeller, half flow for double-flow impeller, at the best efficiency point and head per stage at maximum impeller diameter

SpecificSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

StablePumpH_Q_Curve

Pump H(Q) curve where the maximum head and shut-off head are coincidental, and the total head declines continuously as the rate of flow increases

StandardGasFlowrate

Volume flow rate at standard reference conditions, i.e. 0 °C and 101 325 Pa

StandardGasFlowrate

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

StartingPressure

The starting pressure is the pressure at which a vacuum pump can be switched on and a pumping effect is achieved without damage occurring.

StartingPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

Suction_SpecificSpeed

Speed that characterizes a pump's cavitation performance in terms of its speed, optimum rate of flow per impeller eye at best efficiency point and NPSH3 at best efficiency point for the first stage at maximum impeller diameter

Suction_SpecificSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

SweptVolume

Volume traversed by a single stroke of piston, plunger or diaphragm.

SweptVolume

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

TripSpeed

Speed at which the independent emergency overspeed devices operate to shut down a prime mover

TripSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

TypeNumber

Pure number calculated at the point of best efficiency

VolumeFlowRate

Volume flow rate of the gas removed by the pump from the gas phase within the evacuated chamber.

VolumeFlowRate

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

VolumeFlowRateOfBackingPump

Maximum volume flow rate for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump

VolumeFlowRateOfBackingPump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

WarmUpTimeForAVaporJetPumpOrADiffusionPump

The warm-up time is the time required to heat the blowing agent in the boiling vessel to its working temperature. The initial temperature can either be equal to the ambient temperature or equal to the temperature at which the blowing agent of the vacuum pump can be exposed to atmospheric air without risk.

WarmUpTimeForAVaporJetPumpOrADiffusionPump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5457219

DisplayName: s

Description: second [unit of time]

WaterVaporTolerableLoad

The mass flow rate for water vapor, in a gas ballast pump, in continuous operation and under normal ambient conditions, if the pumped gas is pure water vapor.

WaterVaporTolerableLoad

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4933459

DisplayName: kg/s

Description: kilogram per second

WetCriticalSpeed

Rotor resonant frequency calculated considering the additional support and damping produced by the action of the pumped fluid within rotor

WetCriticalSpeed

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second