The InletConnectionSystemRequirementsTypeprovides static Variablesfor Pump inlet connection specific parameters of the process in which the Pumpis to be usedand is formally defined in Table 96.
Table 96– InletConnectionSystemRequirementsType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionSystemRequirementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupTypedefined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
InletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarationsof the InletConnectionSystemRequirementsType have additional Attributesdefined in Table 97. The Variablesand the associated Descriptionsare based on the standard DIN ISO 21360-1.
Table 97– InletConnectionSystemRequirementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
InletPressure |
|
Pressure at the inlet of the pump, measured at a defined location in the test dome. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|