The InletConnectionSystemRequirementsType provides static Variables for Pump inlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 96.
Table 96 – InletConnectionSystemRequirementsType Definition
Attribute |
Value |
||||
BrowseName |
InletConnectionSystemRequirementsType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
InletPressure |
0:Double |
0:BaseAnalogType |
O, RW |
The InstanceDeclarations of the InletConnectionSystemRequirementsType have additional Attributes defined in Table 97. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.
Table 97 – InletConnectionSystemRequirementsType Attribute values for child Nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
InletPressure |
|
Pressure at the inlet of the pump, measured at a defined location in the test dome. |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |
|