The SystemRequirementsType provides static Variables for parameters of the process in which the Pump is to be used and is formally defined in Table 49.

Table 49 – SystemRequirementsType Definition

Attribute

Value

BrowseName

SystemRequirementsType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

CompressionRatio

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

ExplosionZone

ExplosionZoneOptionSet

0:DataItemType

O, RW

0:HasComponent

Variable

Fieldbus

FieldbusEnum

0:DataItemType

O, RW

0:HasComponent

Variable

Fluid

0:String

0:DataItemType

O, RW

0:HasComponent

Variable

GasContent

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

HeightOfTheInletSideOfTheInstallation

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

HeightOfTheOutletSideOfTheInstallation

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

HeightOfThePump

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumAmbientTemperature

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumFlow

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumHead

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumInletPressure

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumOutletPressure

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumRelativeHumidity

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MaximumTemperature

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MeanTimeBetweenFailures

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumAmbientTemperature

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumFlow

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumHead

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumInletPressure

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumOutletPressure

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumRelativeHumidity

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MinimumTemperature

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

Multi_Phase

0:Boolean

0:TwoStateDiscreteType

O, RW

0:HasComponent

Variable

NetPositiveInletPressureAvailable

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

NormalFlow

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

NpshDatumPlane

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

OperatingMode

OperatingModeEnum

0:DataItemType

O, RW

0:HasComponent

Variable

RatedInletPressureOfTheInstallation

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

RatedPumpUnitTotalHead

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

ReferencePlane

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

RequiredControlMode

ControlModeEnum

0:DataItemType

O, RW

0:HasComponent

Variable

RequiredTime

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

SolidContent

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

Throughput

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

UltimatePressureOfAVacuumPump

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

WorkingTemperature

0:Double

0:BaseAnalogType

O, RW

The InstanceDeclarations of the SystemRequirementsType have additional Attributes defined in Table 50. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN ISO 21360-1, ISO 3529-2, DIN 28400-2, DIN EN 13306 and VDI 3805-4.

Table 50 – SystemRequirementsType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

CompressionRatio

Ratio of the backing pressure, p3, to the inlet pressure, p1, of the vacuum pump without throughput

ExplosionZone

Categories of explosion zones for devices according to 2014/34/EU (ATEX).

Fieldbus

Selected fieldbus for the product

Fluid

Fluid that is handled by the pump at specified operating conditions

GasContent

Proportion of gaseous substance in the liquid to be pumped, either as a contaminant or as vapor from the main body of liquid

GasContent

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

HeightOfTheInletSideOfTheInstallation

Height of the fluid level on the inlet side of the installation, or in the center of the inlet manifold

HeightOfTheInletSideOfTheInstallation

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

HeightOfTheOutletSideOfTheInstallation

Height of the fluid level on the outlet side of the installation or in the center of the outlet manifold

HeightOfTheOutletSideOfTheInstallation

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

HeightOfThePump

Height of the center of the pump

HeightOfThePump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MaximumAmbientTemperature

Highest ambient temperature to be expected under normal circumstances

MaximumAmbientTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MaximumFlow

Greatest rate of flow which is expected at operating conditions

MaximumFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MaximumHead

Highest total head developed by a pump at any rate of flow

MaximumHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MaximumInletPressure

Highest inlet pressure to which the pump is subjected during operation

MaximumInletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumOutletPressure

Maximum possible pressure at outlet, due either to internal energy increase (rotodynamic pumps) or external downstream restrictions (volumetric pumps)

MaximumOutletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumRelativeHumidity

Highest relative humidity that can be expected under normal circumstances.

MaximumRelativeHumidity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MaximumTemperature

Highest fluid temperature to be expected under operating conditions

MaximumTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MeanTimeBetweenFailures

Average of the times between failures

MeanTimeBetweenFailures

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4740434

DisplayName: h

Description: hour

MinimumAmbientTemperature

Lowest ambient temperature to be expected under normal circumstances

MinimumAmbientTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MinimumFlow

Smallest rate of flow which is expected at operating conditions

MinimumFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumHead

Smallest total head developed by a pump at any rate of flow

MinimumHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MinimumInletPressure

Lowest inlet pressure that can occur during operation for the pump

MinimumInletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MinimumOutletPressure

Lowest outlet pressure that can occur during operation for the pump

MinimumOutletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MinimumRelativeHumidity

Lowest relative humidity to be expected under normal circumstances.

MinimumRelativeHumidity

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MinimumTemperature

Lowest fluid temperature to be expected under operating conditions

MinimumTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

Multi_Phase

Comprising a fluid together with substances in solid or gaseous states, whether due to deliberate addition or a change of state caused by a change in conditions. A "True" status means that there is a possibility of multi-phase-fluid and a "False" status means that there is no possibility of multi-phase-fluid.

NetPositiveInletPressureAvailable

Total pressure (including velocity pressure) at the pump inlet connection less the liquid vapor pressure at the present temperature of the liquid

NetPositiveInletPressureAvailable

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

NormalFlow

Rate of flow at which usual operation is expected

NormalFlow

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

NpshDatumPlane

Horizontal plane through the center of the circle described by the external points of the entrance edges of the impeller blades, in the first stage in the case of multi-stage pumps

NpshDatumPlane

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OperatingMode

Specifies whether the pump is to be operated in single, parallel or series connection.

RatedInletPressureOfTheInstallation

Inlet pressure of the installation for the working conditions

RatedInletPressureOfTheInstallation

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

RatedPumpUnitTotalHead

Difference of the total head, at the outlet side of the pump unit from the total head at the inlet side of the pump unit, at which usual operation is expected

RatedPumpUnitTotalHead

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

ReferencePlane

Any horizontal plane for use as the datum for height measurement

ReferencePlane

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

RequiredControlMode

Specifies which control mode is to be used for the use case.

RequiredTime

Time interval throughout which an item is required to be in an up state

RequiredTime

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4740434

DisplayName: h

Description: hour

SolidContent

Proportion of solids contained in the fluid to be pumped, either as a contaminant or as a deliberate useful burden or suspension

SolidContent

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

Throughput

Amount of fluid flowing through a duct

Throughput

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4665393

DisplayName: Pa·m³/s

Description: pascal cubic metre per second

UltimatePressureOfAVacuumPump

The ultimate pressure is the value to which the pressure in a standardized test dome approaches asymptotically during normal operation of the vacuum pump and without gas inlet. A difference can be made between the final pressure caused by gases and the final pressure caused by gases and vapors.

UltimatePressureOfAVacuumPump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

WorkingTemperature

Temperature determined by the given application and fluid.

WorkingTemperature

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin