The OutletConnectionDesignType extends its supertype by Pump outlet connection specific Variables and is formally defined in Table 92.

Table 92 – OutletConnectionDesignType Definition

Attribute

Value

BrowseName

OutletConnectionDesignType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

MaximumAllowableOutletPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

MinimumAllowableOutetPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

OutletAreaOfThePump

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ReliefValveAccumulationPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ReliefValveBackPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ReliefValveReseatPressure

0:Double

0:BaseAnalogType

O, RO

0:HasComponent

Variable

ReliefValveSetPressure

0:Double

0:BaseAnalogType

O, RO

The InstanceDeclarations of the OutletConnectionDesignType have additional Attributes defined in Table 93. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.

Table 93 – OutletConnectionDesignType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

MaximumAllowableOutletPressure

Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

MaximumAllowableOutletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MinimumAllowableOutetPressure

Lowest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

MinimumAllowableOutetPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

OutletAreaOfThePump

Free cross-sectional area of the orifice in the outlet connection of the pump.

OutletAreaOfThePump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067851

DisplayName: m²

Description: square metre

ReliefValveAccumulationPressure

Outlet pressure at which the relief valve will pass the total pump flow.

ReliefValveAccumulationPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

ReliefValveBackPressure

Pressure at the outlet of the relief valve when the valve is closed.

ReliefValveBackPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

ReliefValveReseatPressure

Outlet pressure at which the relief valve will close after passing the total pump flow.

ReliefValveReseatPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

ReliefValveSetPressure

Outlet pressure at which the relief valve begins to open.

ReliefValveSetPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal