The SupervisionAuxiliaryDeviceType provides Variables used for monitoring the Pump auxiliary devices. It is formally defined in Table 41. For the generation of events, the SupervisionAuxiliaryDeviceType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.

Table 41 – SupervisionAuxiliaryDeviceType Definition

Attribute

Value

BrowseName

SupervisionAuxiliaryDeviceType

IsAbstract

false

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

ActuatorElement

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AmbientTemperature

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AuxiliaryDeviceFault

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AuxiliaryMediumAbsence

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AuxiliaryMediumInsufficiency

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AuxiliaryPowerPole

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

AuxiliaryPowerRange

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

CommunicationError

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Corrosion

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Deviation

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

ElectromagneticInterference

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

ElectronicFault

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

EnergySupply

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

EvaluationElectronics

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

ExciterError

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Fouling

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

HumidityElectronics

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Installation

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Interruption

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

LineLength

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

MaterialElectronics

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

MeasuredMaterialElectronics

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

MechanicalDamage

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

OperatingConditions

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Other

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Overloading

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

ParameterSetting

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Peripheral

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

ProcessInfluence

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

SensorElement

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

StartUp

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

TemperatureShock

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

Vibration

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

WearReserveOperation

0:Boolean

0:TwoStateDiscreteType

O, RO

0:HasComponent

Variable

WearReserveWear

0:Boolean

0:TwoStateDiscreteType

O, RO

0:GeneratesEvent

ObjectType

2:CheckFunctionAlarmType

Defined in OPC 10000-100

0:GeneratesEvent

ObjectType

2:FailureAlarmType

Defined in OPC 10000-100

0:GeneratesEvent

ObjectType

2:MaintenanceRequiredAlarmType

Defined in OPC 10000-100

0:GeneratesEvent

ObjectType

2:OffSpecAlarmType

Defined in OPC 10000-100

The InstanceDeclarations of the SupervisionAuxiliaryDeviceType have additional Attributes defined in Table 42. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.

Table 42 – SupervisionAuxiliaryDeviceType Attribute values for child Nodes

BrowsePath

Description Attribute

ActuatorElement

This property indicates a fault in an actuator element.

AmbientTemperature

This property indicates an abnormal ambient temperature.

AuxiliaryDeviceFault

This property indicates a generic failure of an auxiliary device.

AuxiliaryMediumAbsence

This property indicates an absence of or wrong auxiliary medium.

AuxiliaryMediumInsufficiency

This property indicates an insufficiency of auxiliary medium.

AuxiliaryPowerPole

This property indicates an auxiliary power supply wrongly poled.

AuxiliaryPowerRange

This property indicates an off-spec of the auxiliary power range.

CommunicationError

This property indicates a communication error.

Corrosion

This property indicates corrosion/abrasion in parts in contact with medium.

Deviation

This property indicates an inadmissible deviation from measurement.

ElectromagneticInterference

This property indicates an abnormal electromagnetic interference.

ElectronicFault

This property indicates a fault in the device electronics.

EnergySupply

This property indicates an error in internal energy supply.

EvaluationElectronics

This property indicates an error in evaluation electronics.

ExciterError

This property indicates an error in the exciter of the sensor element.

Fouling

This property indicates a fouling on sensor element.

HumidityElectronics

This property indicates an abnormal amount of humidity in electronics area.

Installation

This property indicates an installation fault.

Interruption

This property indicates an interruption of signal path or short circuit.

LineLength

This property indicates that the maximum line length is exceeded.

MaterialElectronics

This property indicates a foreign material in electronics area.

MeasuredMaterialElectronics

This property indicates measured material in electronics area.

MechanicalDamage

This property indicates a mechanical damage.

OperatingConditions

This property indicates a fault due to non-compliance with specified operating conditions.

Other

This property indicates other faults.

Overloading

This property indicates an overloading.

ParameterSetting

This property indicates a parameter setting error.

Peripheral

This property indicates an error in peripherals.

ProcessInfluence

This property indicates a fault due to process influence.

SensorElement

This property indicates a fault in a sensor element.

StartUp

This property indicate an installation fault or fault during start-up.

TemperatureShock

This property indicates an excessive temperature shock.

Vibration

This property indicates an excessive vibration or impact load.

WearReserveOperation

This property indicates that the wear reserve is used up by operation.

WearReserveWear

This property indicates that the wear reserve is used up by wear.