The SupervisionAuxiliaryDeviceType provides Variables used for monitoring the Pump auxiliary devices. It is formally defined in Table 41. For the generation of events, the SupervisionAuxiliaryDeviceType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.
Table 41 – SupervisionAuxiliaryDeviceType Definition
Attribute |
Value |
||||
BrowseName |
SupervisionAuxiliaryDeviceType |
||||
IsAbstract |
false |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. |
|||||
0:HasComponent |
Variable |
ActuatorElement |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AmbientTemperature |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryDeviceFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryMediumAbsence |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryMediumInsufficiency |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryPowerPole |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
AuxiliaryPowerRange |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
CommunicationError |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Corrosion |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Deviation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ElectromagneticInterference |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ElectronicFault |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
EnergySupply |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
EvaluationElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ExciterError |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Fouling |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
HumidityElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Installation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Interruption |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
LineLength |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MaterialElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MeasuredMaterialElectronics |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
MechanicalDamage |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
OperatingConditions |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Other |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Overloading |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ParameterSetting |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Peripheral |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
ProcessInfluence |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
SensorElement |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
StartUp |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
TemperatureShock |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
Vibration |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WearReserveOperation |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:HasComponent |
Variable |
WearReserveWear |
0:Boolean |
0:TwoStateDiscreteType |
O, RO |
0:GeneratesEvent |
ObjectType |
2:CheckFunctionAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:FailureAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:MaintenanceRequiredAlarmType |
Defined in OPC 10000-100 |
||
0:GeneratesEvent |
ObjectType |
2:OffSpecAlarmType |
Defined in OPC 10000-100 |
The InstanceDeclarations of the SupervisionAuxiliaryDeviceType have additional Attributes defined in Table 42. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.
Table 42 – SupervisionAuxiliaryDeviceType Attribute values for child Nodes
BrowsePath |
Description Attribute |
ActuatorElement |
This property indicates a fault in an actuator element. |
AmbientTemperature |
This property indicates an abnormal ambient temperature. |
AuxiliaryDeviceFault |
This property indicates a generic failure of an auxiliary device. |
AuxiliaryMediumAbsence |
This property indicates an absence of or wrong auxiliary medium. |
AuxiliaryMediumInsufficiency |
This property indicates an insufficiency of auxiliary medium. |
AuxiliaryPowerPole |
This property indicates an auxiliary power supply wrongly poled. |
AuxiliaryPowerRange |
This property indicates an off-spec of the auxiliary power range. |
CommunicationError |
This property indicates a communication error. |
Corrosion |
This property indicates corrosion/abrasion in parts in contact with medium. |
Deviation |
This property indicates an inadmissible deviation from measurement. |
ElectromagneticInterference |
This property indicates an abnormal electromagnetic interference. |
ElectronicFault |
This property indicates a fault in the device electronics. |
EnergySupply |
This property indicates an error in internal energy supply. |
EvaluationElectronics |
This property indicates an error in evaluation electronics. |
ExciterError |
This property indicates an error in the exciter of the sensor element. |
Fouling |
This property indicates a fouling on sensor element. |
HumidityElectronics |
This property indicates an abnormal amount of humidity in electronics area. |
Installation |
This property indicates an installation fault. |
Interruption |
This property indicates an interruption of signal path or short circuit. |
LineLength |
This property indicates that the maximum line length is exceeded. |
MaterialElectronics |
This property indicates a foreign material in electronics area. |
MeasuredMaterialElectronics |
This property indicates measured material in electronics area. |
MechanicalDamage |
This property indicates a mechanical damage. |
OperatingConditions |
This property indicates a fault due to non-compliance with specified operating conditions. |
Other |
This property indicates other faults. |
Overloading |
This property indicates an overloading. |
ParameterSetting |
This property indicates a parameter setting error. |
Peripheral |
This property indicates an error in peripherals. |
ProcessInfluence |
This property indicates a fault due to process influence. |
SensorElement |
This property indicates a fault in a sensor element. |
StartUp |
This property indicate an installation fault or fault during start-up. |
TemperatureShock |
This property indicates an excessive temperature shock. |
Vibration |
This property indicates an excessive vibration or impact load. |
WearReserveOperation |
This property indicates that the wear reserve is used up by operation. |
WearReserveWear |
This property indicates that the wear reserve is used up by wear. |