The OutletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 104.

Table 104 – OutletConnectionImplementationType Definition

Attribute

Value

BrowseName

OutletConnectionImplementationType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the ConnectionImplementationType defined in 7.46, i.e. inheriting the InstanceDeclarations of that Node.

0:HasComponent

Variable

HeightOfTheOutletConnection

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

MeanRatedVelocityAtOutlet

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

RatedOutletPressure

0:Double

0:BaseAnalogType

O, RW

0:HasComponent

Variable

TotalHeadAtOutletAreaOfThePump

0:Double

0:BaseAnalogType

O, RW

The InstanceDeclarations of the OutletConnectionImplementationType have additional Attributes defined in Table 105. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.

Table 105 – OutletConnectionImplementationType Attribute values for child Nodes

BrowsePath

Value Attribute

Description Attribute

HeightOfTheOutletConnection

Height of the center of the outlet connection of the pump.

HeightOfTheOutletConnection

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MeanRatedVelocityAtOutlet

Rated flow at pump outlet connection divided by the inlet area of the pump.

MeanRatedVelocityAtOutlet

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

RatedOutletPressure

Outlet pressure of the pump at the guarantee point with rated flow and rated speed, as well as rated inlet pressure, for rotodynamic pumps only.

RatedOutletPressure

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

TotalHeadAtOutletAreaOfThePump

Head observed at outlet area of the pump, corresponding to the sum of the height, pressure head and velocity head.

TotalHeadAtOutletAreaOfThePump

0:EngineeringUnits

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre