OPC 30141: OPC UA for PROFIenergy

Release 1.00
2021-03-15

Copyright (c) 2021 OPC Foundation
Generated on 3/19/2021 8:41:15 PM.

This document is subject to the license terms described here.

This document is a copy of the original which can be found here.

Table of Contents

1 Scope

2 Normative references

3 Terms, abbreviated terms and conventions
    3.1 Overview
    3.2 OPC UA for PROFIenergy terms
        3.2.1 PE Energy Management
        3.2.2 Standby Management
        3.2.3 Standby Management Entity
        3.2.4 Energy Saving Mode
        3.2.5 Energy Measurement
        3.2.6 Metering Point
        3.2.7 Sleep Mode WOL
    3.3 Abbreviated terms
    3.4 Conventions used in this document
        3.4.1 Conventions for Node descriptions
        3.4.2 NodeIds and BrowseNames
        3.4.3 Common Attributes

4 General information to PE Energy Management and OPC UA
    4.1 Introduction to PE Energy Management
        4.1.1 General
        4.1.2 Standby Management
        4.1.3 Energy Measurement
        4.1.4 Sleep Mode WOL
    4.2 Introduction to OPC Unified Architecture
        4.2.1 What is OPC UA?
        4.2.2 Basics of OPC UA
        4.2.3 Information modelling in OPC UA

5 Use cases

6 PE Energy Management Information Model

7 PROFIenergy Service Access Point Information Model

8 OPC UA ObjectTypes
    8.1 Standby Management
        8.1.1 EnergyStandbyManagementType
        8.1.2 EnergySavingModesContainerType
        8.1.3 EnergySavingModeStatusType
        8.1.4 EnergySavingModeType
    8.2 Energy Measurement
        8.2.1 Overview
        8.2.2 EnergyMeasurementType
        8.2.3 Interfaces for EnergyProfiles
    8.3 Sleep Mode WOL Functionality
        8.3.1 EnergyDevicePowerOffType
    8.4 PeServiceAccessPointType

9 OPC UA VariableTypes
    9.1 MeasurementValueType

10 OPC UA DataTypes
    10.1 Structures
        10.1.1 StandbyModeTransitionDataType
        10.1.2 EnergyStateInformationDataType
        10.1.3 PeVersionDataType
        10.1.4 AcPeDataType
        10.1.5 AcPpDataType
    10.2 Enumerations
        10.2.1 PeClassEnumeration
        10.2.2 PeSubclassEnumeration
        10.2.3 AccuracyDomainEnumeration
        10.2.4 AccuracyClassEnumeration

11 OPC UA ReferenceTypes
    11.1 Represents Reference Type
    11.2 HasEnergyStandbyManagement Reference Type
    11.3 HasEnergyMeasurement Reference Type
    11.4 HasEnergyPowerOff Reference Type

12 Profiles and Conformance Units
    12.1 Conformance Units
    12.2 Profiles
        12.2.1 Profile list
        12.2.2 Server Facets
        12.2.3 Client Facets

13 Namespaces
    13.1 Namespace Metadata
    13.2 Handling of OPC UA Namespaces

Annex A (normative) OPC UA for PROFIenergy Namespace and mappings
    A.1 Namespace and identifiers for OPC UA for PROFIenergy Information Model

Annex B (Informative) Relationship to PROFIenergy Concepts
    B.1 PE Entity

Annex C (Informative) PROFIenergy Common Application Profile
    C.1 What is PROFIenergy?
    C.2 Services of PROFIenergy
    C.3 PE Object Model
    C.4 PE State Model
    C.5 Mapping of Measurement values
        C.5.1 Energy Measurements