7.4 STSysDryingType ObjectType Definition

The STSysDryingType provides relevant variables and parameters for controlling and monitoring a drying station or zone of a cleaning and pretreatment machine and is formally defined in Table 21.

Table 21 - STSysDryingType Definition
Attribute Value
BrowseNameSTSysDryingType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 9:STSysType defined in OPC 40700
0:HasComponentObject3:Monitoring3:MonitoringTypeO
0:HasAddInObject3:Components3:MachineComponentsTypeO
Conformance Units
STCleaningPretreatment STSysDryingType Basic
STCleaningPretreatment STSysDryingType Identification
STCleaningPretreatment STSysDryingType Advanced

Monitoring represents a collection of variables that are not assigned to a component but to the overall system.

Components is an add-in used to assign components (e.g. of STCompType) to the system.

The components of the STSysDryingType have additional subcomponents which are defined in Table 22.

Table 22 - STSysDryingType Additional Subcomponents
Source Path Reference NodeClass BrowseName DataType TypeDefinition Others
3:Monitoring
3:Process

0:HasComponentObject<EmissionControl>7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<Humidity>7:ProcessValueTypeOP
3:Components0:HasComponentObject<Cooler>STCompCoolerTypeOP
3:Components0:HasComponentObject<Dryer>STCompDryerTypeOP
3:Components0:HasComponentObject<Heater>STCompHeaterTypeOP
3:Components0:HasComponentObject<PressurizedAir>STCompPressurizedAirTypeOP
3:Components0:HasComponentObject<Pump>STCompPumpTypeOP
3:Components0:HasComponentObject<Valve>STCompValveTypeOP
3:Components0:HasComponentObject<Vessel>STCompVesselTypeOP

EmissionControl refers to the concentration of pollutants released into a volume of air from industrial, automotive, or other sources. It plays a crucial role in minimizing environmental impact and ensuring compliance with regulatory standards for air quality. Suggested unit: ppm.

Humidity represents the measured or calculated actual relative humidity in the process chamber as well as the surrounding atmosphere. Suggested unit: %.