7.1 STSysAuxiliaryType ObjectType Definition
The STSysAuxiliaryType provides relevant variables and parameters for controlling and monitoring auxiliary systems or zones of a cleaning and pretreatment machine and is formally defined in Table 15.
| Attribute | Value | ||||
| BrowseName | STSysAuxiliaryType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of the 9:STSysType defined in OPC 40700 | |||||
| 0:HasComponent | Object | 3:Monitoring | 3:MonitoringType | O | |
| 0:HasAddIn | Object | 3:Components | 3:MachineComponentsType | O | |
| Conformance Units | |||||
|---|---|---|---|---|---|
| STCleaningPretreatment STSysAuxiliaryType Basic | |||||
| STCleaningPretreatment STSysAuxiliaryType Identification | |||||
| STCleaningPretreatment STSysAuxiliaryType Advanced |
Monitoring represents a collection of variables that are not assigned to a component but to the overall system.
Components is an add-in used to assign components (e.g. of STCompType) to the system.
The components of the STSysAuxiliaryType have additional subcomponents which are defined in Table 16.
| Source Path | Reference | NodeClass | BrowseName | DataType | TypeDefinition | Others | ||
| 0:HasComponent | Object | <ParticleCountClassXLiquid> | 7:ProcessValueType | OP | |||
| 3:Components | 0:HasComponent | Object | <Condenser> | STCompCondenserType | OP | |||
| 3:Components | 0:HasComponent | Object | <Cooler> | STCompCoolerType | OP | |||
| 3:Components | 0:HasComponent | Object | <Heater> | STCompHeaterType | OP | |||
| 3:Components | 0:HasComponent | Object | <PressurizedAir> | STCompPressurizedAirType | OP | |||
| 3:Components | 0:HasComponent | Object | <Pump> | STCompPumpType | OP | |||
| 3:Components | 0:HasComponent | Object | <Valve> | STCompValveType | OP | |||
| 3:Components | 0:HasComponent | Object | <Vessel> | STCompVesselType | OP |
ParticleCountClassXLiquid is a placeholder to represent the measured or calculated number of particles of a specified size class (Size Class X) in liquid of the rinsing or cleaning stage in relation to a reference volume as specified by VDA 19/ISO 16232. This parameter can be re-used for each Size Class required for evaluation. Suggested unit: -.