7.13 STCompHeaterType ObjectType Definition

The STCompHeaterType provides relevant variables and parameters for controlling and monitoring a heater component of a cleaning and pretreatment machine and is formally defined in Table 39.

Table 39 - STCompHeaterType Definition
Attribute Value
BrowseNameSTCompHeaterType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 9:STCompType defined in OPC 40700
0:HasComponentObject3:Monitoring3:MonitoringTypeO
Conformance Units
STCleaningPretreatment STCompHeaterType Basic
STCleaningPretreatment STCompHeaterType Identification
STCleaningPretreatment STCompHeaterType Advanced

Monitoring represents a collection of variables that are not assigned to a component but to the overall system.

The components of the STCompHeaterType have additional subcomponents which are defined in Table 40.

Table 40 - STCompHeaterType Additional Subcomponents
Source Path Reference NodeClass BrowseName DataType TypeDefinition Others
3:Monitoring
3:Process

0:HasComponentObject<HeatingPower> 7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<Temperature> 7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<EmissionControl> 7:ProcessValueTypeOP

HeatingPower represents the measured or calculated actual electric real power consumption of a component used for a heating task. Suggested unit: kW.

Temperature represents the measured or calculated actual temperature. Suggested unit: °C.

EmissionControl refers to the concentration of pollutants released into a volume of air from industrial, automotive, or other sources. It plays a crucial role in minimizing environmental impact and ensuring compliance with regulatory standards for air quality. Suggested unit: ppm.