7.11 STCompCoolerType ObjectType Definition

The STCompCoolerType provides relevant variables and parameters for controlling and monitoring a cooler component of a cleaning and pretreatment machine and is formally defined in Table 35.

Table 35 - STCompCoolerType Definition
Attribute Value
BrowseNameSTCompCoolerType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 9:STCompType defined in OPC 40700
0:HasComponentObject3:Monitoring3:MonitoringTypeO
Conformance Units
STCleaningPretreatment STCompCoolerType Basic
STCleaningPretreatment STCompCoolerType Identification
STCleaningPretreatment STCompCoolerType Advanced

Monitoring represents a collection of variables that are not assigned to a component but to the overall system.

The components of the STCompCoolerType have additional subcomponents which are defined in Table 36.

Table 36 - STCompCoolerType Additional Subcomponents
Source Path Reference NodeClass BrowseName DataType TypeDefinition Others
3:Monitoring
3:Process

0:HasComponentObject<CoolingPower> 7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<Temperature> 7:ProcessValueTypeOP

CoolingPower represents the measured or calculated actual electric real power consumption of a component used for a cooling task. Suggested unit: kW.

Temperature represents the measured or calculated actual temperature. Suggested unit: °C.