7.11 STCompCoolerType ObjectType DefinitionThe STCompCoolerType provides relevant variables and parameters for controlling and monitoring a cooler component of a cleaning and pretreatment machine and is formally defined in Table 35 .
Table 35 - STCompCoolerType Definition
Attribute
Value
BrowseName STCompCoolerType IsAbstract False
References
Node Class
BrowseName
DataType
TypeDefinition
Other
Subtype of the 9:STCompType defined in OPC 40700 0:HasComponent Object 3:Monitoring 3:MonitoringType O
Conformance Units
STCleaningPretreatment STCompCoolerType Basic STCleaningPretreatment STCompCoolerType Identification STCleaningPretreatment STCompCoolerType Advanced
Monitoring represents a collection of variables that are not assigned to a component but to the overall system.
The components of the STCompCoolerType have additional subcomponents which are defined in Table 36 .
Table 36 - STCompCoolerType Additional Subcomponents
Source Path
Reference
NodeClass
BrowseName
DataType
TypeDefinition
Others
0:HasComponent Object <CoolingPower> 7:ProcessValueType OP
0:HasComponent Object <Temperature> 7:ProcessValueType OP
CoolingPower represents the measured or calculated actual electric real power consumption of a component used for a cooling task. Suggested unit: kW.
Temperature represents the measured or calculated actual temperature. Suggested unit: °C.