7.14 STCompPressurizedAirType ObjectType Definition

The STCompPressurizedAirType provides relevant variables and parameters for controlling and monitoring a pressurized air component of a cleaning and pretreatment machine and is formally defined in Table 41.

Table 41 - STCompPressurizedAirType Definition
Attribute Value
BrowseNameSTCompPressurizedAirType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 9:STCompType defined in OPC 40700
0:HasComponentObject3:Monitoring3:MonitoringTypeO
Conformance Units
STCleaningPretreatment STCompPressurizedAirType Basic
STCleaningPretreatment STCompPressurizedAirType Identification
STCleaningPretreatment STCompPressurizedAirType Advanced

Monitoring represents a collection of variables that are not assigned to a component but to the overall system.

The components of the STCompPressurizedAirType have additional subcomponents which are defined in Table 42.

Table 42 - STCompPressurizedAirType Additional Subcomponents
Source Path Reference NodeClass BrowseName DataType TypeDefinition Others
3:Monitoring
3:Process

0:HasComponentObject<Temperature> 7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<PressurizedAirPressure> 7:ProcessValueTypeOP
3:Monitoring
3:Process

0:HasComponentObject<PressurizedAirVolumeflow> 7:ProcessValueTypeOP

Temperature represents the measured or calculated actual temperature. Suggested unit: °C.

PressurizedAirPressure specifies the pressure of pressurized air used to remove solvent or dirt, typically measured in bar. Exact measurement is essential to ensure proper operation of the drying or cleaning process. Suggested unit: bar.

PressurizedAirVolumeflow refers to volume of pressurized air passing through a system or component within a specific time frame, typically measured in liters per minute or cubic meters per hour. Accurate control of pressurized airflow is essential for ensuring efficient system operation and meeting process requirements. Suggested unit: m3/h.