Search
40 result(s) for OutputArguments
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClassspecify the arguments that shall be used by a client when calling the Method. OutputArguments O Argument[] The OutputArguments Property specifies the result returned from the Method call. The Method ... Properties may be defined for Methods using HasProperty References . The Properties InputArguments and OutputArguments specify the input arguments and output arguments of the Method . Both contain an array
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.4 OptionalPlaceholderOptionalPlaceholder only defines the BrowseName. An instance or subtype defines the InputArguments and OutputArguments . A subtype shall also change the ModellingRule to Optional or Mandatory . The Method is optional
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.5 MandatoryPlaceholderMandatoryPlaceholder only defines the BrowseName. An instance or subtype defines the InputArguments and OutputArguments . A subtype shall also change the ModellingRule to Mandatory . The Method is mandatory for instances
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.2 ParametersServer , e.g. based on an exception. If the Method execution fails but the outputArguments provide additional information like an application specific error code, the Method should return a StatusCode with ... request header or if no diagnostic information was encountered in processing of the request. outputArguments [] BaseDataType List of output argument values. An empty list indicates that there are no output
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.4 StatusCodessupported for the Object instance. Uncertain The Method execution fails but the outputArguments provide additional information like an application specific error code. Table 62 - Call Input Argument Result Codes Symbolic
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.27 AuditUpdateMethodEventTypeHasProperty Variable StatusCodeId StatusCode PropertyType Optional HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory HasProperty Variable OutputArguments BaseDataType[] PropertyType Optional Conformance Units Auditing Method Auditing Method Output This EventType inherits all Properties ... Method . This parameter can be null if no input arguments were provided. OutputArguments provide the values of the output arguments returned by the Method . This parameter can be null
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelHasProperty Variable StatusCodeId StatusCode PropertyType Mandatory HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory HasProperty Variable OutputArguments BaseDataType[] PropertyType Mandatory ConformanceUnits Base Info Client Events This EventType inherits all Properties ... method. This parameter can be null if no input arguments were provided. OutputArguments identifies the output arguments of the method. This parameter can be null if no output arguments were
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.1 Overviewassociated state transition. The Method instances referenced by the ProgramStateMachineType identify the InputArguments and OutputArguments required for the Method calls to Program Invocations of that ProgramStateMachineType . Table 8 specifies ... References Target BrowseName Value Target TypeDefinition NOTES Causes Start HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Suspend HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Resume HasProperty InputArguments PropertyType
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.3 Standard propertiesthat ProgramStateMachineType shall pass the specified arguments. Methods can reference a set of OutputArguments . For each ProgramStateMachineType , a set of OutputArguments is defined for the supported Program Control Methods
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelHasProperty Variable 0:StatusCodeId 0:StatusCode 0:PropertyType M 0:HasProperty Variable 0:OutputArguments 0:BaseDataType[] 0:PropertyType M ConformanceUnits UAFX AutomationComponent Auditing Connection Management This EventType inherits all Properties ... AuditUpdateMethodEventType . Their semantics are defined in OPC 10000-5 . The StatusCodeId and OutputArguments are as defined in AuditUpdateMethodEventType as Optional . They are included here only to indicate that they
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation6.2.1.2 ResetStatistics Methodsignature of this Method is specified below. The Method does not have Input - or OutputArguments . Signature ResetStatistics ( ); Method Result Codes (defined in Call Service) Result Code Description Bad_UserAccessDenied
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition6.3.9 WoT Actions MappingObject that implements IWoTAssetType (see 6.3.8 ). The Method and its InputArguments and OutputArguments Properties are mapped to a TD as shown in Table 15 . Table 15 - WoT OPC UA Method
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices9.2 IdentifyDeviceactivation of a LED. Signature: IdentifyDevice (); The method has no Input - or OutputArguments . Table 3 - IdentifyDevice Method AddressSpace Definition Attribute Value BrowseName IdentifyDevice References Node Class BrowseName DataType TypeDefinition Modelling
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices9.5 ResetAllErrorsreset all errors of the device. Signature : ResetAllErrors(); The method has no Input - or OutputArguments . Table 5 - ResetAllErrors Method AddressSpace Definition Attribute Value BrowseName ResetAllErrors References Node Class BrowseName DataType
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems9.2 IdentifyDeviceactivation of a LED. Signature: IdentifyDevice (); The method has no Input - or OutputArguments . Table 4 - IdentifyDevice Method AddressSpace Definition Attribute Value BrowseName IdentifyDevice References Node Class BrowseName DataType TypeDefinition Modelling
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems9.5 ResetAllErrorsreset all errors on the device. Signature : ResetAllErrors(); The method has no Input - or OutputArguments . Table 5 - ResetAllErrors Method AddressSpace Definition Attribute Value BrowseName ResetAllErrors References Node Class BrowseName DataType
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systemscall the method StopDosing. Signatures : StartDosing(); StopDosing(); The methods have no Input - or OutputArguments . Table 16 - StartDosing Method AddressSpace Definition Attribute Value BrowseName StartDosing References Node Class BrowseName DataType TypeDefinition
-
OPC-40082-6 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 6: Granulate Drying Devices17.4 LogoutMachineUserActualUser then becomes false again. Signature LogoutMachineUser(); The Method has no Input - or OutputArguments . Table 43 - LogoutMachineUser Method AddressSpace Definiton Attribute Value BrowseName LogoutMachineUser References Node Class BrowseName DataType TypeDefinition
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsSLEEP_5. Signatures ActivateSleepMode (); DeactivateSleepMode (); The methods have no Input - or OutputArguments . Table 39 - ActivateSleepMode Method AddressSpace Definition Attribute Value BrowseName ActivateSleepMode References Node Class BrowseName DataType TypeDefinition Modelling Rule
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions14.6 ClearMESMessageempty string and Severity to 0. Signature ClearMESMessage (); The method has no Input - or OutputArguments . Table 48 - ClearMESMessage Method AddressSpace Definition Attribute Value BrowseName ClearMESMessage References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitionsmachine has stopped. Signatures EnableAutomaticRun (); DisableAutomaticRun (); The methods have no Input- or OutputArguments . Table 51 - EnableAutomaticRun Method AddressSpace Definition Attribute Value BrowseName EnableAutomaticRun References Node Class BrowseName DataType TypeDefinition Modelling
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsVariable InputArguments Argument[] 0:PropertyType Mandatory Signature ResetWatchDog (); The method has no Input - or OutputArguments . Table 55 - ResetWatchDog Method AddressSpace Definition Attribute Value BrowseName ResetWatchDog References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions14.7.6 RequestTestSamplesample depends on the product/machine configuration. Signature RequestTestSample (); The method has no Input - or OutputArguments . Table 56 - RequestTestSample Method AddressSpace Definition Attribute Value BrowseName RequestTestSample References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.2 StartJobmethod does not change the MachineMode. Signature StartJob (); The method has no Input - or OutputArguments . Table 87 - StartJob Method AddressSpace Definition Attribute Value BrowseName StartJob References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.3 InterruptJobmachine stops or continuous running. Signature InterruptJob (); The method has no Input - or OutputArguments . Table 88 - InterruptJob Method AddressSpace Definition Attribute Value BrowseName InterruptJob References Node Class BrowseName DataType TypeDefinition
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.4 FinishJobshall be shown on the machine. Signature FinishJob (); The method has no Input - or OutputArguments . Table 89 - FinishJob Method AddressSpace Definition Attribute Value BrowseName FinishJob References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.7.9 StopAtCycleEndcurrent cycle. Signature StopAtCycleEnd (); The method has no Input - or OutputArguments . Table 91 - StopAtCycleEndMethod AddressSpace Definition Attribute Value BrowseName StopAtCycleEnd References Node Class BrowseName DataType TypeDefinition Modelling Rule
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.7.10 ResetJobCounterscounters for the job to 0. Signature ResetJobCounters (); The method has no Input - or OutputArguments . Table 92 - ResetJobCounters Method AddressSpace Definition Attribute Value BrowseName ResetJobCounters References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.7.11 ResetBoxCounterscurrent box to 0. Signature ResetBoxCounters (); The method has no Input - or OutputArguments . Table 93 - ResetBoxCounters Method AddressSpace Definition Attribute Value BrowseName ResetBoxCounters References Node Class BrowseName DataType TypeDefinition Modelling
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.7.12 ResetAverageCycleTimeaverage cycle time for the job. Signature ResetAverageCycleTime (); The method has no Input - or OutputArguments . Table 94 - ResetAverageCycleTime Method AddressSpace Definition Attribute Value BrowseName ResetAverageCycleTime References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.10 ResetMonitoringSetValue to adapt the monitoring. Signature ResetMonitoring (); The method has no Input - or OutputArguments . Table 130 - ResetMonitoring Method AddressSpace Definition Attribute Value BrowseName ResetMonitoring References Node Class BrowseName DataType TypeDefinition
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions24.4 AutoTuningOnself-optimisation of the controller. Signature AutoTuningOn (); The method has no Input - or OutputArguments . Table 134 - AutoTuningOn Method AddressSpace Definition Attribute Value BrowseName AutoTuningOn References Node Class BrowseName DataType TypeDefinition
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions24.5 AutoTuningOffprocess (no control parameters are changed) Signature AutoTuningOff (); The method has no Input - or OutputArguments . Table 135 - AutoTuningOff Method AddressSpace Definition Attribute Value BrowseName AutoTuningOff References Node Class BrowseName DataType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions25.6 ResetStatus to NOT_DUE_0. Signature Reset (); The method has no Input - or OutputArguments . Table 138 - Reset Method AddressSpace Definition Attribute Value BrowseName Reset References Node Class BrowseName DataType TypeDefinition
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions35.2 RunDiagnosticsdiagnosis functions already running. Signature RunDiagnostics (); The method has no Input - or OutputArguments . Table 161 - RunDiagnostics Method AddressSpace Definition Attribute Value BrowseName RunDiagnostics References Node Class BrowseName DataType TypeDefinition Modelling
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions35.3 StopDiagnosticschanges immediately to "Off". Signature StopDiagnostics (); The method has no Input - or OutputArguments . Table 162 - StopDiagnostics Method AddressSpace Definition Attribute Value BrowseName StopDiagnostics References Node Class BrowseName DataType
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.25.1 TriggerSystem . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 55 . Signature Trigger ( ); Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.1 LoadConfigurationFileSystem . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 66 . Signature LoadConfigurationFile ( ); Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.2 SaveConfigurationFileConfigurationFile. The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 67 . Signature SaveConfigurationFile ( ); Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.49.1 DrainTestSystem . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 105 . Signature DrainTest ( ); Table