OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsMonitoredParameterType The MonitoredParameterType is used for process parameters that are monitored by the client. Figure 17 - MonitoredParameterType Overview Table 126 - MonitoredParameterType Definition Attribute Value BrowseName MonitoredParameterType IsAbstract False References Node
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devicesHasComponent Variable TemperatureReturnLine 0:Double 0:AnalogItemType O, RO 0:HasComponent Object TemperatureDifference 3:MonitoredParameterType O 0:HasComponent Object FlowRate 3:MonitoredParameterType O 0:HasComponent Variable PressureMainLine 0:Double ... HasComponent Variable PressureReturnLine 0:Double 0:AnalogItemType O, RO 0:HasComponent Object PressureDifference 3:MonitoredParameterType O 0:HasComponent Variable ActualProcessPower 0:Double 0:AnalogItemType O, RO 0:HasComponent Variable ActualRegulationRatio
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices10.25 ExternalChannelTypeHasProperty Variable SwitchedOn 0:Boolean 0:PropertyType O, RO 0:HasComponent Object Temperature 3:MonitoredParameterType O 0:HasComponent Variable TemperatureMainLine 0:Double 0:AnalogItemType O, RO 0:HasComponent Variable TemperatureReturnLine ... Double 0:AnalogItemType O, RO 0:HasComponent Object TemperatureDifference 3:MonitoredParameterType O 0:HasComponent Object FlowRate 3:MonitoredParameterType O 0:HasComponent Variable PressureMainLine 0:Double 0:AnalogItemType
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices11 Alarmsgeneral events) or the NodeId of a child element (e.g. a variable of MonitoredParameterType if this is out of tolerance). For the Severity Property (included in BaseEventType ) the following classes
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices13.6 HeatUpSetting for heat up procedure. HeatUp is an alternative to the SetRamp functionality of MonitoredParameterType (see 16 HeatUpType
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices15.12 LoadCurrentLoadCurrent Information about the load current in Ampere. The MonitoredParameterType is defined
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices15.13 LoadPowerLoadPower Information about the load power in Watt. The MonitoredParameterType is defined
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices16 HeatUpTypeHeatUpType HeatUpType is optional and an alternative to the SetRamp functionality of MonitoredParameterType defined in OPC 40083 . With HeatUpType , it can be pre-defined how the control circuit
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems13.1 Conformance UnitsOperationType Server OPC 40083 Tolerances Support of Status, UpperTolerance and LowerTolerance in the MonitoredParameterType and ControlledParameterType and the according alarms. Server OPC 40082-3 DosingFunction Support of StartDosing, StopDosing
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systems12.2 Levelactual hopper level). Values are given as relative values between 0 - 100 %. MinValue of MonitoredParameterType is used to trigger an alarm
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systems12.4 StartFillingStartFilling Method to fill the Component up to the MaxValue of the MonitoredParameterType in the Level Variable. No Arguments. Signature: StartFilling(); Table 32 - StartFilling Method AddressSpace Definition Attribute Value BrowseName
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.2 SetValuemonitored parameter. The value of this variable is writeable by the client. As the MonitoredParameterType is not used to control parameters, this is only for information/Process monitoring
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsValue BrowseName ControlledParameterType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of MonitoredParameterType 0:HasComponent Variable SetRampUp 0:Double 0:AnalogItemType O, RW 0:HasComponent Variable SetRampDown ... ClosedLoopControlType O The variables SetRampUp and SetRamp down, which are only readable in the MonitoredParameterType , are writable in the ControlledParameterType . If SetValue (already writeable in MonitoredParameterType ) is changed
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitionscomponent of the machine (e.g. temperature zone) or a process parameter expressed as MonitoredParameterType (e.g. temperature) Classification 0:UInt16 Classification of the error, if a process parameter expressed as MonitoredParameterType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitionsused, if the cause of the alarm is a process variable expressed as MonitoredParameterType . It adds the Variable Status . As values, the same as defined in Table 127 are used ... AlarmConditionType ) shall be set to the NodeId of the element of the MonitoredParameterType which causes the error (e.g. UpperTolerance2 if this value is exceeded by the ActualValue
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions32.2.6 MonitoredParameterMonitoredParameter Measured value. The MonitoredParameterType , which also gives tolerance values, is defined in Clause
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type Definitionsroll on both sides (in the direction of the material flow). The MonitoredParameterType is defined in OPC 40083. Unit: mm or inch
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type Definitionsbetween the rolls on both sides (in the direction of the material flow). The MonitoredParameterType is defined in OPC 40083. Unit: mm or inch
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type Definitions9.4.5 ContactForceContactForce Contact force between the rolls (mainly measured indirectly via the fluid pressure). The MonitoredParameterType is defined in OPC 40083. Unit
-
OPC-40084-3 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 3: Extruder7.7.8 Throughputoptional to cover also pure feeders, it is mandatory for dosing units. The MonitoredParameterType is defined
-
OPC-40084-3 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 3: Extruder7.8.6 MaterialTemperatureMaterialTemperature Actual temperature of the material inside the feeder in °C or °F. The MonitoredParameterType is defined
-
OPC-40084-4 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 4: Haul-off6.5 ForceForce This Object controls the pulling force of the haul-off. The MonitoredParameterType is defined
-
OPC-40084-6 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 6: Filter6.5 WasteOutputfiltrated material which is filtered out of the melt [kg/h, pound/h]. The MonitoredParameterType is defined
-
OPC-40084-6 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 6: Filterfiltrated material which is filtered out of the melt regarding to the throughput [%]. The MonitoredParameterType is defined
-
OPC-40084-9 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 9: Cutter6.4 ProductSpeedused for monitoring the speed of the product which shall be cut. The MonitoredParameterType is defined