OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeldescribed in the OPC 10000-26 Log Event EventType clause. Diagnostics is a FunctionalGroup ( Folder ) that contains Variables that report diagnostic statistics and counters (see OPC 10000-100 Recommended FunctionalGroup
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.2 FxAssetType definitionReference can. For a formal definition of the AssetConnectorType, see 6.3.4 . Diagnostics is a FunctionalGroup ( Folder ) that contains Variables that report diagnostic statistics and counters (see OPC 10000-100 Recommended ... FunctionalGroup BrowseNames). The UpTime Variable provides the module's uptime since the last power-on. The CurrentCPUUtilization Variable provides the current CPU utilisation in percent (the calculation is vendor-specific
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelcontain two FunctionalGroups ( Configuration or Tuning ) to further organise configuration information. The optional Configuration FunctionalGroup contains Variables representing the configuration items of the FunctionalEntity (see OPC 10000-100 Recommended FunctionalGroup ... BrowseNames ). The optional Tuning FunctionalGroup contains Variables that can be used to optimise the behaviour of the FunctionalEntity (see OPC 10000-100 Recommended FunctionalGroup BrowseNames ). The optional Capabilities
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionManage that failed. This applies to local and remote calls. The Diagnostics FunctionalGroup contains Variables and Methods for diagnostics (see OPC 10000-100 Recommended FunctionalGroup BrowseNames ). For UAFX, this includes
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponentinformation that is consistent with the information defined in AuditConnectionCleanupEventType. Server UAFX AutomationComponent Diagnostics FunctionalGroup Supports the Diagnostics FunctionalGroup of the AutomationComponentType . Server UAFX AutomationComponent Diagnostics EstablishCalls Supports the EstablishCallCount ... Variable of the AutomationComponent Diagnostics FunctionalGroup . Server UAFX AutomationComponent Diagnostics EstablishCallFailed Supports the EstablishCallFailedCount Variable of the AutomationComponent Diagnostics FunctionalGroup . Server UAFX AutomationComponent Diagnostics CloseCall Supports the CloseCalCount Variable
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.4 UAFX FxAssetinstance of AssetConnectorType or subtype of it in the Folder . Server UAFX IAssetExtensions Diagnostics FunctionalGroup Supports the Diagnostics FunctionalGroup of the IAssetExtensions Interface. Server UAFX IAssetExtensions Diagnostics PowerOnUpTime Supports ... PowerOnUpTime Variable of the IAssetExtensions Interface Diagnostics FunctionalGroup . Server UAFX IAssetExtensions Diagnostics CurrentCPUUtilization Supports the CurrentCPUUtilization Variable of the IAssetExtensions Interface Diagnostics FunctionalGroup . Server UAFX IAssetExtensions Diagnostics MaxCPUUtilization Supports
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.5 UAFX FunctionalEntityServer UAFX IFunctionalEntity ConfigurationData Configuration Supports ConfigurationData of the IFunctionalEntity Interface, including the Configuration FunctionalGroup of the IFunctionalEntity Interface ConfigurationData Component. Server UAFX IFunctionalEntity ConfigurationData Tuning Supports ConfigurationData ... IFunctionalEntity Interface, including the Tuning FunctionalGroup of the IFunctionalEntity Interface ConfigurationData Component. Server UAFX IFunctionalEntity ConnectionEndpoints Supports ConnectionEndpoints of the IFunctionalEntity Interface . Server UAFX ConnectionEndpointsFolder CommHealth Supports CommHealth
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerUAFX ConnectionManager AggregatedCurrentState Supports the AggregatedCurrentState Variable of the ConnectionManagerType . Server UAFX ConnectionManager Diagnostics FunctionalGroup Supports the Diagnostics FunctionalGroup of the ConnectionManagerType . Server UAFX ConnectionManager Diagnostics EstablishCall Supports the EstablishCallCount ... Variable of the ConnectionManagerType Diagnostics FunctionalGroup . Server UAFX ConnectionManager Diagnostics CloseCall Supports the CloseCallCount Variable of the ConnectionManagerType Diagnostics FunctionalGroup . Server UAFX ConnectionManager Diagnostics EstablishCallFailed Supports the EstablishCallFailedCount Variable
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicesconfiguration, diagnostics, asset management, condition monitoring and others. FunctionalGroups are specified in 4.4 . A FunctionalGroup called Identification can be used to organize identification information of this TopologyElement (see 4.4.2 ). Identification
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.4.1 Modelused when the elements are components in other parts of the TopologyElement that the FunctionalGroup belongs to. This includes Properties , Variables , and Methods of the TopologyElement or in Objects that ... useful in different application scenarios and therefore referenced from more than one FunctionalGroup . FunctionalGroups can be nested. FunctionalGroups can directly be instantiated. In this case, the BrowseName of a FunctionalGroup
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesWell-Known FunctionalGroup BrowseNames Table 15 includes a list of FunctionalGroups with name and purpose. If Servers expose a FunctionalGroup that corresponds to the described purpose, they should ... domain specific. Some common ones are defined in the OperationCounter Interface (see 4.5.5 ). This FunctionalGroup can be organized into other FunctionalGroups , so Clients shall expect that several browse hops
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.4.3 UIElement TypeUIElement Type Servers can expose UIElements providing user interfaces in the context of their FunctionalGroup container. Clients can load such a user interface and display it on the Client side ... elements. The UIElementType is abstract and is mainly used as filter when browsing a FunctionalGroup . Only subtypes can be used for instances. No concrete UIElements are defined in this specification
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices5.4 ConnectionPointConnectionPoints have Properties and other components that they inherit from the TopologyElementType . The NetworkAddress FunctionalGroup includes all Parameters to specify the protocol-specific address information of the connected Device . These ... Parameters can be components of the NetworkAddress FunctionalGroup , of the ParameterSet , or another Object . <ProfileIdentifier> identifies the Communication Profile that this ConnectionPoint supports. ProtocolType and Communication Profile
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.3.1 Generalsince this is the identifier passed by the Client in read/write requests. The Identification FunctionalGroup organizes Parameters that help identify a topology element. Clients can compare the values of these
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesParameters or even Methods are required, all required elements shall be organized in a FunctionalGroup called Identification . Figure B.3 illustrates the Identification FunctionalGroup with an example. Note that companion standards ... define the Identification contents for their model. Figure B.3 - Example of an Identification FunctionalGroup
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.3 Operation Countersthose counters. In order to provide access to the counters, the concept of a FunctionalGroup as defined in OPC 10000-100 is used. This specification just defines ... provide the counters using different access paths, but they should provide the 2:OperationCounters FunctionalGroup as well. This FunctionalGroup might be organized into other FunctionalGroups , so Clients shall expect that
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.1.1 Overviewspecific configurations. A concrete Ctrl Configuration type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet Object is defined ... point of view. Temporary, incomplete configurations are allowed, e.g. during a configuration process. The FunctionalGroup GlobalVars contains the corresponding list of Ctrl Variables declared by the key word VAR_GLOBAL
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.1.3 MethodSet componentsCtrlConfigurationType MethodSet Attribute Value BrowseName MethodSet References Node Class BrowseName Description Modelling Rule Configuration FunctionalGroup The following components are also referenced from the FunctionalGroup Configuration using Organizes References . HasComponent Method
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.2.1 Overviewspecific resources. A concrete Ctrl Resource type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet Object is defined ... with possible Ctrl Program types that can be instantiated in the Ctrl Resource . The FunctionalGroup GlobalVars contains the corresponding list of GlobalVars that may be accessed in the programmable Controller
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.2.4 MethodSet componentsCtrlResourceType MethodSet Attribute Value BrowseName MethodSet References NodeClass BrowseName Description ModellingRule Configuration FunctionalGroup The following components are also referenced from the FunctionalGroup Configuration using Organizes References . HasComponent Method Start This
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.1 Object RuntimeParametersObject RuntimeParameters This FunctionalGroup is used to organize runtime configuration parameters and Methods . All standard or vendor specific runtime parameters of AutoID Devices shall be exposed below this FunctionalGroup . FunctionalGroups ... Address Space . The FunctionalGroupType is defined in OPC 10000-100 . Predefined parameters for this FunctionalGroup are defined in Table 8 and described below. The parameter CodeTypes allows the user
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.2 Object IODataObject IOData This FunctionalGroup is used to organize IO data from sensors and actuators connected to the AutoID Device . All vendor or configuration specific IO data of AutoID Devices shall ... exposed below this FunctionalGroup . FunctionalGroups can be nested. The IO data may also be exposed in other parts of the AutoID Device OPC UA Server Address Space . An IO data
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.3 Object DiagnosticsObject Diagnostics This FunctionalGroup is used to organize diagnostic data from the AutoID Device . All diagnostics data of AutoID Devices shall be exposed below this FunctionalGroup . FunctionalGroups can be nested ... changes. The FunctionalGroupType is defined in OPC 10000-100 . Predefined parameters for this FunctionalGroup are defined in Table 8 and described below. Presence identifies if there currently is seen
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.2.3.1 Object RuntimeParametersObject RuntimeParameters This FunctionalGroup is inherited from the AutoIdDeviceType and described in 6.1 . Predefined runtime parameters for for this FunctionalGroup are defined in Table 10 and described below. Parameter TemplateName
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.3.3.1 Object RuntimeParametersObject RuntimeParameters This FunctionalGroup is inherited from the AutoIdDeviceType and described in 6.1 . Predefined runtime parameters for the OpticalReaderDeviceType are defined in Table 12 . The parameters TemplateName and MatchCode
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.3.1 Object RuntimeParametersObject RuntimeParameters This FunctionalGroup is inherited from the AutoIdDeviceType and described in 6.1 . Predefined runtime parameters for for this FunctionalGroup are defined in Table 15 and described below. Parameter CodeTypesRWData
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>10.4.2 ApplicationIdEnumerationApplicationIdEnumeration The ApplicationIdEnumeration is an enumeration that defines the use of the FunctionalGroup . Its values are defined in Table 36 . Table 36 - ApplicationIdEnumeration Items Name Value Description AdjustSetValue 0 Functional
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>12.2.2 TopologyElementTypeParameterSet . For both types of information (Commands and Parameters) also references in FunctionalGroup nodes are created, so that an OPC Client may represent a joint user interface (see Figure ... BrowseName and DisplayName of the FunctionalGroup -Nodes are based on the grouping in IFunction.FunctionInfo (FunctionGroup) and IData.DataInfo (DataGroup). Information about IO signals are provided in a folder ProcessDataSet, which contains
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>Identification FunctionalGroup The Identification FunctionalGroup organizes references to parameters, which may be used to identify the device and its device type. The list of parameters that shall be provided ... Identification FunctionalGroup is defined in Table 64 . Table 64 - Identification FunctionalGroup mapping References BrowseName Modelling Rule Organizes ManufacturerId O Organizes DeviceTypeId O Organizes 2:NetworkAddress O Organizes DeviceTag M Organizes
-
OPC-30200 – OPC UA for Commercial Kitchen Equipment5.2.3.6 HACCPValues objectdevice provides HACCP -relevant measured values, these measured values must be referenced via the FunctionalGroup HACCPValues . For HACCP-relevant measured values the corresponding variable must reference an information object
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsresults of the FunctionalUnit . FunctionalUnitState the StateMachine that is used for this FunctionalUnit . Operational Functional Group that organizes Properties and Methods for this FunctionalUnit . SupportedPropertiesSet provides references to variables
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsController configuration. For example, the K factor of a PID control. Operational is a FunctionalGroup that shall organize the CurrentState property of the ControlFunctionState StateMachine and all its remote invocable
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices SystemCraneMotionDeviceSystemType. variables are also referenced by an Organizes from either Configuration or Operational FunctionalGroup. ProtectiveFunctions is a Folder for both hardware and software functions designed to affect motion ... Components allows the listing of all subcomponents of a CraneMotionDeviceSystem . The Operational FunctionalGroup contains variables which represent the current state of the crane (motion device system). This is read-only
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.2.1 PumpClassPump and value of the PumpClass Variable of an instance of the FunctionalGroup Design of a Pump . EXAMPLE 1 The pump P1 is of the PumpClass positive displacement pump. EXAMPLE
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.2.2 FunctionalGroupFunctionalGroup Instance of the 2:FunctionalGroupType or one of its subtypes. Note 1 to entry: In this specification, FunctionalGroup usually refers to an instance of a Pump specific ObjectType like
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps6.2.3 FunctionalGroupsFunctionalGroups Where it made sense, the BrowseName of a FunctionalGroup was taken from the recommendation in OPC 10000-100 . A FunctionalGroup that would have no Variables , Objects , or Methods
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpscase the additional Variables , Objects , or Methods shall be added to an appropriate FunctionalGroup of the component. It is important, that the Variables , Objects , or Methods which are added match ... description of the FunctionalGroup they are added to. If there is no FunctionalGroup available the Variables , Objects , and Methods fit in, the manufacturer or system integrator shall create
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpsadded to the 3:Machines Object defined in ( OPC 40001-1 ). The optional FunctionalGroup 2:Configuration provides collections of Nodes for manufacturer data about the Pump and user data about ... process environment, such as maximum operating temperature and minimum flow rate. The optional FunctionalGroup Documentation provides Nodes that are used to store Pump documentation, such as an operating manual
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.5 ComponentClassComponent and value of the ComponentClass Variable of an instance of the FunctionalGroup Design of a Component . EXAMPLE 1 The compressor C1 is of the ComponentClass Axial turbo compressor. EXAMPLE
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.7 DeviceClassCASPart and value of the DeviceClass Property of an instance of the FunctionalGroup Identification of a CASPart . Note 1 to entry: Available DeviceClasses for CASPart of this specification are listed
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.8 FunctionalGroupFunctionalGroup Instance of the FunctionalGroupType or one of its subtypes. Note 1 to entry: In this specification, FunctionalGroup usually refers to an instance of a Compressed Air System specific ObjectType
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems6.1.2 FunctionalGroupsFunctionalGroups When applicable, the BrowseName of a FunctionalGroup was taken from the recommendation in OPC 10000-100 . A FunctionalGroup that would have no Variables , Objects , or Methods if instantiated shall
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemscase the additional Variables , Objects , or Methods shall be added to an appropriate FunctionalGroup of the Component . It is important, that the Variables , Objects , or Methods which are added match ... description of the FunctionalGroup they are added to. If there is no FunctionalGroup available the Variables , Objects , and Methods fit in, the manufacturer or system integrator shall create
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAlarms and Conditions Most CASParts have an optional FunctionalGroup with the default BrowseName Events. This FunctionalGroup provides Objects for common alarms and conditions. In total four conditions are defined: EmergencyStop
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAirnets . The optional Object Components organizes all installed Components by their ComponentClasses . The optional FunctionalGroup Identification provides Properties to identify a Compressed Air System . The optional Object
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsCASType instance. Figure 20 shows an example on how to instantiate the FunctionalGroup Components for an Airnet in the AddressSpace of an OPC UA Server . Figure 20 - Airnet Components Example ... optional FunctionalGroup Configuration provides Variables for configuring the behavior of an Airnet . The optional Object ElectricalCircuit provides Quantities for the electrical ports of an Airnet . The mandatory FunctionalGroup Identification provides
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsTopologyElementType 0:HasComponent Object 2:Identification 4:MachineryComponentIdentificationType M The optional FunctionalGroup Analyses provides Objects and Methods for analyses that can be invoked on the Main Control System . The optional ... FunctionalGroup Configuration provides Objects and Methods for configuring the behavior of the Main Control System . The optional Object ElectricalCircuit provides Quantities for the electrical input of the Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsVariables of the FluidQuantitiesType only AbsolutePressure, DewPoint, RelativeHumidity, and Temperature are instantiated. The optional FunctionalGroup Configuration provides a framework for properties aimed at configuring the behavior of a Component ... delta of coolant conditions on a Component in a Compressed Air System . The optional FunctionalGroup Design provides static design properties of a Component in a Compressed Air System and acts
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsHasComponent Object Design SensorDesignType O 0:HasComponent Object 2:Operational OperationalType O The optional FunctionalGroup Calibration provides Variables useful for the documentation of the sensor calibration. The optional FunctionalGroup Maintenance ... provides Variables useful for the documentation of the sensor maintenance. The optional FunctionalGroup Operational is extended with an OptionalPlaceholder <Quantity> for the sensor Quantity . When instantiating a SensorType