Search
72 result(s) for DataSetReader
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub3.1.4 DataSetReaderDataSetReader entity receiving DataSetMessages from a Message Oriented Middleware Note 1 to entry: A DataSetReader is the component that extracts a DataSetMessage from a NetworkMessage received from the Message Oriented
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.2.1 GeneralDataSetMessage has been selected as relevant, it will be forwarded to the corresponding DataSetReader for decoding into a DataSet . See 5.4.2.2 for further information about this DataSet reading process
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.2.2 Message receptionsame as for the Publisher . Each DataSetMessage of interest is passed on to a DataSetReader . Here, the DataSetMetaData is used to decode the DataSetMessage content to a DataSet . The DataSetMetaData
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.5.3 Key acquisition handshakesinitial pull or push fails, the affected PubSub components like WriterGroup or DataSetReader stay in the PreOperational state. If the updates fail and the PubSub components do not have
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.6.2.2 Broker-less model with OPC UA UDPmaps data fields from UADP DataSetMessages to internal Variables can be configured through the DataSetReader Object and dispatcher in the Subscriber . The configuration of a DataSetReader defines how to decode
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.6.4 QoS configurationshown in Figure 18 and Figure 19 the PriorityLabel from a WriterGroup , DataSetReader or PubSubConnection TransportSettings will be translated into actual values to be used on the wire. Together with
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.1 Overviewrelated to a particular NetworkMessage . The NetworkMessage related filter settings are on the DataSetReaders . DataSetReader parameters represent settings for filtering of received NetworkMessages and DataSetMessages as well as settings ... SubscribedDataSet parameters define the processing of the decoded DataSet in the Subscriber for one DataSetReader . PublishSubscribe is the overall management of the PubSub groupings. It contains a list of PublishedDataSets
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubinclude setup of network communication and security keys. If the PubSub component is a DataSetReader , the state shall change to Operational after the first key frame or event DataSetMessage
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.7.1 PublisherIdinside a PubSubConnection . The filter setting on the Subscriber side is contained in the DataSetReader parameters. Valid DataTypes are UInteger and String . A zero UInteger and a Null or empty
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.4 DataSetMetaDataPublisher . If the DataSetMetaData changes in the Publisher and the MajorVersion was changed, the DataSetReader needs an update of the DataSetMetaData for further operation. If the update cannot be retrieved ... duration of the MessageReceiveTimeout , the State of the DataSetReader shall change to Error . The related PublishedDataSet is defined in 6.2.3 . The DataSetMetaDataType is defined in 6.2.3.2.3 . The options for retrieving
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.6 MessageReceiveTimeoutmaximum acceptable time between two DataSetMessages . The time starts when the state of the DataSetReader changes to Operational . If there is no new DataSetMessage received within this period, the DataSetReader
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.11 SecurityKeyServicesoverwrite the SecurityKeyServices parameter of the ReaderGroup if the SKS is different for the DataSetReader
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.12 DataSetReaderPropertiesparameter is an array of DataType KeyValuePair that specifies additional properties for the configured DataSetReader . The KeyValuePair DataType is defined in OPC 10000-5 and consists of a QualifiedName
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.13.1 DataSetReaderDataTypeDataSetReaderDataType This Structure DataType is used to represent the DataSetReader parameters. The DataSetReaderDataType is formally defined in Table 59 . Table 59 - DataSetReaderDataType structure Name Type Description Allow Subtypes DataSetReaderDataType Structure ... Name String The name of the DataSetReader. The name shall be unique across a ReaderGroup . It is recommended to use a human readable name. Enabled Boolean The enabled state
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.13.2 DataSetReaderTransportDataTypeDataSetReaderTransportDataType This Structure DataType is an abstract base type for transport-specific DataSetReader parameters. The DataSetReaderTransportDataType is formally defined in Table 61 . Table 61 - DataSetReaderTransportDataType structure Name Type Description DataSetReaderTransportDataType
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.13.3 DataSetReaderMessageDataTypeDataSetReaderMessageDataType This Structure DataType is an abstract base type for message mapping specific DataSetReader parameters. The DataSetReaderMessageDataType is formally defined in Table 63 . Table 63 - DataSetReaderMessageDataType structure Name Type Description
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.10.2.3 FieldTargetDataTyperelation between a field in a DataSetMessage and a target Variable in a DataSetReader . The FieldTargetDataType is formally defined in Table 69 . Table 69 - FieldTargetDataType structure Name Type Description FieldTargetDataType ... used to define the override value handling behaviour if the State of the DataSetReader is not Operational or if the corresponding field in the DataSet contains a Bad StatusCode
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.11.1 Published data itemsallow writing of the StatusCode and the OverrideValueHandling is set to Disabled , the DataSetReader shall indicate the configuration error by setting the DataSetReader state to Error . In all other configurations
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.3.1.1.1 Relationship of Timing parametersUADP WriterGroup . The ReceiveOffset and the ProcessingOffset are defined as parameters of the UADP DataSetReader in 6.3.1.4 . Figure 29 - Timing offsets in a PublishingInterval
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.3.1.4.10 UadpDataSetReaderMessageDataTypeUadpDataSetReaderMessageDataType This Structure DataType is used to represent UADP message mapping specific DataSetReader parameters. It is a subtype of the DataSetReaderMessageDataType defined in 6.2.9.13.3 . The UadpDataSetReaderMessageDataType is formally defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubJsonDataSetReaderMessageDataType structure This Structure DataType is used to represent JSON DataSetMessage mapping specific DataSetReader parameters. It is a subtype of the DataSetReaderMessageDataType defined in 6.2.9.13.3 . The JsonDataSetReaderMessageDataType is formally defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.6.1 AddressAddress parameter contains the network address information for the communication middleware related to the DataSetReader . The different Structure DataTypes used to represent the Address are defined in 6.2.7.5.3 . The parameter
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.6.2 QosCategoryQosCategory Selects the general categorty of QoS the DataSetReader requires. Further details are defined in 6.4.1.1.1 . The parameter shall be null or empty if no QoS related parameters
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.6.3 DatagramQosDatagramQos The DatagramQos parameter contains the QoS related parameters for the DataSetReader as array of ReceiveQosDataType Structures . The abstract ReceiveQosDataType is defined in 6.4.1.1.5 . The concrete subtypes are used
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.6.4 Topicdata stream from the Publisher that contains the DataSetMessages of interest for the DataSetReader . The Topic is defined by the Publisher
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.2.6.1 QueueNameQueueName parameter with DataType String specifies the queue in the Broker where the DataSetReader can receive NetworkMessages with the DataSet of interest sent by the Publisher . This could
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.2.6.4 RequestedDeliveryGuaranteeRequestedDeliveryGuarantee The RequestedDeliveryGuarantee parameter with DataType BrokerTransportQualityOfService specifies the delivery guarantees the DataSetReader negotiates with the broker for all messages received. The DataType BrokerTransportQualityOfService is defined in 6.4.2.1 . The value ... NotSpecified is not allowed on the DataSetReader . If the selected delivery guarantee cannot be applied, the DataSetReader shall set the state to Error
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.1 Generalsuch fields are not present, the Subscriber must know the missing information from the DataSetReader configuration. One scenario is that a Publisher is sending NetworkMessages with a fixed layout ... case the DataSetWriterId , the offset and size of the DataSetMessages is known from the DataSetReader configuration. The identification is done in this case by the group header with the WriterGroupId
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.4.2 NetworkMessage layoutDataSetMessages , the Subscriber must know the number and size of DataSetMessages from the DataSetReader configuration. The group header is the default option to provide a reference to this information ... this case the number and size of the DataSetMessages is known from the DataSetReader configuration for the combination of WriterGroupId and NetworkMessageNumber . Timestamp DateTime The time the NetworkMessage was created
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.3 Authenticationshall be performed according to the configured AuthenticationProfileUri of the PubSubConnection , DataSetWriterGroup , DataSetWriter or DataSetReader entities. If no authentication information is provided in the form of ResourceUri and AuthenticationProfileUri , SASL
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.1 Generalcreating DataSetMessages for delivery through a Message Oriented Middleware . On the Subscriber side, a DataSetReader represents the transport settings for receiving DataSetMessages from a Message Oriented Middleware and the SubscribedDataSet ... example defines two PublishedDataSets published through one connection and one group and one DataSetReader used to subscribe one DataSet . Figure 44 depicts the information flow and the related ObjectTypes from
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.2 PublishSubscribeTypestatus and the relation to other PubSub Objects like PubSubConnection , PubSubGroup , DataSetWriter and DataSetReader are defined in 6.2.1 . The Diagnostics Object provides the current diagnostic information for the PublishSubscribe Object
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.3 SetSecurityKeysApplicationUri that matches the ApplicationUri in the SecurityKeyServices parameter of the WriterGroup , ReaderGroup or DataSetReader objects using the SecurityGroupId . Signature SetSecurityKeys ( [in] String SecurityGroupId, [in] String SecurityPolicyUri, [in] IntegerId CurrentTokenId
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubObject . A successful removal of the PubSubConnection Object removes all associated groups, DataSetWriter and DataSetReader Objects . Before the Objects are removed, their state is set to Disabled . The Client should
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.2 PubSubConfigurationRefMaskreferenced DataSetWriter . ReferenceReader 5 The element operation is applied to the referenced DataSetReader . ReferenceWriterGroup 6 The element operation is applied to the referenced WriterGroup . ReferenceReaderGroup 7 The element operation
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.2 PubSubConnectionTypestatus and the relation to other PubSub Objects like PublishSubscribe , PubSubGroup , DataSetWriter and DataSetReader are defined in 6.2.1 . The Diagnostics Object provides the current diagnostic information for a PubSubConnectionType Object
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.5 RemoveGroup Method (Deprecated)connection. A successful removal of the PubSubGroup Object removes all associated DataSetWriter or DataSetReader Objects . Before the Objects are removed, their state is set to Disabled . The Client should
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.2 PubSubGroupTypestatus and the relation to other PubSub Objects like PubSubConnection , DataSetWriter and DataSetReader are defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.9 ReaderGroupTypeReaderGroupType This ObjectType is a concrete type for Objects representing DataSetReader groupings for PubSub connections. The ReaderGroupType is formally defined in Table 282 . Table 282 - ReaderGroupType definition Attribute Value BrowseName
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.10 AddDataSetReader Method (Deprecated)parameters and the DataSetReaderDataType are defined in 6.2.9 . DataSetReaderNodeId The NodeId of the new DataSetReader Object. Method Result Codes ResultCode Description Bad_InvalidArgument The Server is not able to apply ... group. Bad_ResourceUnavailable The Server does not have enough resources to add the DataSetReader . Bad_UserAccessDenied The Session user does not have rights to create the DataSetReader . Table 283 specifies
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubRemoveDataSetReader Method (Deprecated) This deprecated Method is used to remove a DataSetReader Object from the group. The state of the DataSetReader is set to Disabled before the Object is removed ... Server . Signature RemoveDataSetReader ( [in] NodeId DataSetReaderNodeId ); Argument Description DataSetReaderNodeId NodeId of the DataSetReader to remove from the group. Method Result Codes ResultCode Description Bad_NodeIdUnknown The DataSetReaderNodeId is unknown
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.8.1 OverviewOverview Figure 50 depicts the ObjectType for the PubSub DataSetReader model and its components and the relations to other parts of the model. Figure 50 - DataSet Reader model overview
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.8.2 DataSetReaderTypeDataSetWriterId is defined in 6.2.9.3 . The DataSetMetaData is defined in 6.2.9.4 . If the DataSetReader receives an updated DataSetMetaData , the DataSetReader shall update the Property DataSetMetaData . The DataSetFieldContentMask is defined ... mapping defines specific parameters. The Status Object provides the current operational state of the DataSetReader . The PubSubStatusType is defined in 9.1.10 . The state machine for the status and the relation
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.8.5 CreateTargetVariables MethodResultCode Description Bad_NothingToDo An empty list of Variables was provided. Bad_InvalidState The DataSetReader is not configured yet or the ConfigurationVersion does not match the version in the Publisher ... AddDataConnections . Bad_TooManyMonitoredItems The Server has reached its maximum number of items for the DataSetReader object. Bad_InvalidState The TargetNodeId is already used by another connection. Bad_TypeMismatch The Server
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.8.6 CreateDataSetMirror MethodNodeId of the created parent Node . Method Result Codes ResultCode Description Bad_InvalidState The DataSetReader is not configured yet or the ConfigurationVersion does not match the version in the Publisher
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.2.2 AddTargetVariables MethodResultCode Description Bad_NothingToDo An empty list of Variables was provided. Bad_InvalidState The DataSetReader is not configured yet or the ConfigurationVersion does not match the version in the Publisher ... AddDataConnections . Bad_TooManyMonitoredItems The Server has reached its maximum number of items for the DataSetReader object. Bad_InvalidState The TargetNodeId is already used by another target Variable . Bad_TypeMismatch
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.2.3 RemoveTargetVariables MethodResultCode Description Bad_NothingToDo An empty list of Variables was provided. Bad_InvalidState The DataSetReader is not configured yet or the ConfigurationVersion does not match the version in the DataSetMetaData
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.4.3 RemoveSubscribedDataSet Methodremove a standalone subscribed DataSet Object from a subscribed DataSet Folder . If a DataSetReader is connected, the DataSetReader is removed too. The Client shall be authorized to modify the configuration
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.4.5 RemoveDataSetFolder Methodsuccessful removal of the SubscribedDataSetFolderType Object removes all associated StandaloneSubscribedDataSetType Objects and their associated DataSetReader Objects . Before the Objects are removed, their state is changed to Disabled . The Client shall
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.5 StandaloneSubscribedDataSetTypeObjectType represents a Subscriber defined standalone DataSet . A standalone subscribed DataSet can exist without DataSetReader and is used to define a DataSet from the Subscriber side. A DataSetReader ... Property with DataType Boolean indicates if the standalone subscribed DataSet is connected to a DataSetReader . A standalone subscribed DataSet can only be connected to one DataSetReader . If a DataSetReader
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.10.1 PubSubStatusTypeindicate and change the status of a PubSub Object like PubSubConnection, DataSetWriter or DataSetReader . The PubSubStatusType is formally defined in Table 307 . Table 307 - PubSubStatusType definition Attribute Value BrowseName PubSubStatusType
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.2.1.3 UadpDataSetReaderMessageTypeUadpDataSetReaderMessageType This ObjectType represents UADP message mapping specific parameters for a DataSetReader . The UadpDataSetWriterMessageType is formally defined in Table 338 . Table 338 - UadpDataSetReaderMessageType definition Attribute Value BrowseName UadpDataSetReaderMessageType IsAbstract False
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.2.2.3 JsonDataSetReaderMessageTypeJsonDataSetReaderMessageType This ObjectType represents UADP message mapping specific parameters for a DataSetReader . The JsonDataSetReaderMessageType is formally defined in Table 341 . Table 341 - JsonDataSetReaderMessageType definition Attribute Value BrowseName JsonDataSetReaderMessageType IsAbstract False
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubDatagramDataSetReaderTransportType This ObjectType represents datagram transport protocol mapping specific parameters for a DataSetReader . The DatagramDataSetReaderTransportType is formally defined in Table 344 . Table 344 - DatagramDataSetReaderTransportType definition Attribute Value BrowseName DatagramDataSetReaderTransportType IsAbstract
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.3.2.4 BrokerDataSetReaderTransportTypeBrokerDataSetReaderTransportType This ObjectType represents broker transport protocol mapping specific parameters for a DataSetReader . The BrokerDataSetReaderTransportType is formally defined in Table 349 . Table 349 - BrokerDataSetReaderTransportType definition Attribute Value BrowseName BrokerDataSetReaderTransportType IsAbstract
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubB.2.4 AuthenticationAuthentication is performed according to the configured AuthenticationProfileUri of the PubSubConnection , DataSetWriterGroup , DataSetWriter or DataSetReader entities. If no authentication information is provided in the form of ResourceUri and AuthenticationProfileUri , SASL
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubB.3.3 AuthenticationAuthentication is performed according to the configured AuthenticationProfileUri of the PubSubConnection , DataSetWriterGroup , DataSetWriter or DataSetReader entities. If no authentication information is provided in the form of ResourceUri and AuthenticationProfileUri , SASL
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network Modelstructure with a PriorityLabel . For the subscriber side these values are specified on the DataSetReader level. AddPriorityMappingEntry allows to add an entry to this instance of PriorityMappingTableType . DeletePriorityMappingEntry allows
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelEach FunctionalEntity contains a PubSubConnectionEndpoint (Con_A1 and Con_B1), which references a DataSetReader and a DataSetWriter . The PubSub instances are configured to exchange data between AutomationComponents
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.2 EstablishConnections signaturematch the ConnectionEndpoint . Bad_ConfigurationError The version of the DataSet related to the DataSetReader and/or DataSetWriter referenced by the CommunicationLinks does not match the expected version. Bad_NothingToDo Establishing communication
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.9.2 PubSubdescribed in 6.2.4.3.11 . The EstablishConnections implementation shall verify the SubscribedDataSet associated with the referenced DataSetReader for each element in ConnectionEndpointConfigurations having a ToDataSetReader Reference . If ExpectedSubscribedDataSetVersion MajorVersion ... implementation shall verify that ConnectionEndpoints with their IsPersistent Property set to TRUE reference a DataSetReader and/or DataSetWriter which are persisted, including all parent Objects , i.e., WriterGroup , ReaderGroup , PubSubConnection and PublishSubscribe
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.10.2 PubSubPubSub The EstablishConnections implementation shall enable the DataSetReader and DataSetWriter referenced by ToDataSetReader and/or ToDataSetWriter References for each element in ConnectionEndpointConfigurations . It shall also ensure that the parent Objects ( WriterGroup
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.5.2 CloseConnections behaviourcommunication model for a ConnectionEndpoint , the Method implementation shall only disable the DataSetReader and DataSetWriter referenced by ToDataSetReader and/or ToDataSetWriter References if no further References from other ConnectionEndpoints exist. Their
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelServer 0:PublishSubscribe 0:<PubSubConnection> 0:<ReaderGroup> 0:<DataSetReader> 3:ToDataSetWriter True 0:Objects 0:Server 0:PublishSubscribe 0:<PubSubConnection ... Reference (see 6.2.4.3.9.2 ). If present, the ToDataSetReader Reference (see 11.21 ) shall point to the DataSetReader with which this ConnectionEndpoint is associated. It shall be present if the PubSubConnectionEndpoint references InputVariables
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.1 ActionEstablishConnectionsEnabled / ActionEstablishConnectionsDisabled / ActionEstablishConnectionscommand sequence. A disabled communication model has Enabled flags set to FALSE for all DataSetReader and DataSetWriter configuration elements and to TRUE for all other elements ( WriterGroup , ReaderGroup , PubSubConnection ... command sequence. A disabled communication model has Enabled flags set to FALSE for all DataSetReader and DataSetWriter configuration elements and to TRUE for all other elements ( WriterGroup , ReaderGroup , PubSubConnection
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelPubSubConfiguration , the entity generating the ConnectionConfigurationSet may set their names (i.e., PubSubConnection , ReaderGroup , WriterGroup , DataSetReader , DataSetWriter ) to a specific value or to null. If set to null, a unique name
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelEstablishConnections Method and provides the configuration of references between a ConnectionEndpoint and a DataSetReader and/or a DataSetWriter . NOTE The PubSub configuration elements, including the DataSetReader and/or DataSetWriter to be used ... Description PubSubCommunicationLinkConfigurationDataType Structure Subtype of CommunicationLinkConfigurationDataType DataSetReaderRef 0:PubSubConfigurationRefDataType If not null, specifies the DataSetReader as supplied with the PubSubCommunicationConfigurationDataType . The ConfigurationMask shall contain a ReferenceReader bit only. ExpectedSubscribedDataSetVersion
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.1 Overviewconfiguration information in Flow1 and Sub1 to update the communication model. CommunicationLinks indicate which DataSetReader and DataSetWriter contained in the communication model are relevant for this ConnectionEndpoint . This information
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.7 PubSub DataSetsDataSets within the PubSubConfiguration , e.g. PublishedDataSets in publishedDataSets and SubscribedDataSets as part of the DataSetReader . Preconfigured DataSets are used by setting the dataSetName in the DataSetWriter or DataSetReader
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.6.1 Overviewwith dashed-dotted lines): ConnectionEndpointParameter Variables CommunicationLinks, PreconfiguredPublishedDataSet, and PreconfiguredSubscribedDataSet are related to DataSetReader and DataSetWriter in the PubSubConfiguration; PubSubCommunicationFlowConfiguration Object including its SubscriberConfiguration child Objects and SecurityKeyServerAddress Object, contain
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconfigured on the ReaderGroup and do not need to be repeated in each DataSetReader . For the example illustrated in Figure E.5 , a ReaderGroup in AC_A is generated based
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.6.5 ConnectionConfigurationSet and DataSetReader As illustrated in Figure E.29 , the configuration of the DataSetReader can be derived from the ConnectionEndpointParameter , the SubscriberConfiguration and its parent Object . Figure E.29 - ConnectionConfigurationSet ... DataSetReader It is recommended to update PublisherId, WriterGroupId and DataSetWriterId after issuing the ReserveCommunicationIdsCmd ; see E.2 for details. The values are set to correspond to the Publisher of the DataSetMessage