Search
35 result(s) for UInteger
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.8.3 DataType NodeClassAttribute shall be mandatory for DataTypes derived from Enumeration, OptionSet and subtypes of UInteger representing an OptionSet . For such DataTypes , the Attribute shall contain a structure of the DataType EnumDefinition ... information. OptionSetValues O LocalizedText[] The OptionSetValues Property shall be applied to OptionSet DataTypes and UInteger DataTypes representing bit masks . An OptionSet DataType or UInteger DataType is used to represent
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.8.5.2 DataTypeRefinement ObjectsDataType of a field being refined is BaseDataType , Structure , Number , Integer or UInteger, the DataType of the field can be restricted by using a subtype or SubtypeRestriction ... DataType of a Variable refining a field is BaseDataType , Structure , Number , Integer or UInteger, then the AccessLevelEx bit NoSubDataTypes of the Variable shall be true. If the DataType
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model7.29 BitFieldTypemore bits. Subtypes of this VariableType shall have a DataType of UInteger or one of its subtypes. Its ValueRank shall be either Scalar (-1) or a single dimensional Array ... Table 99 - BitFieldType definition Attribute Value BrowseName BitFieldType IsAbstract True ValueRank ScalarOrOneDimension DataType UInteger References NodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseDataVariableType defined in 7.4 . HasProperty Variable
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model12.34 EnumDescriptionInt32 , the DataType is an Enumeration . If the builtInType is one of the UInteger DataTypes or ExtensionObject , the DataType is an OptionSet . Its representation in the AddressSpace is defined
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsNumber, Integer and UInteger Number , Integer and UInteger are abstract simple types defined in OPC 10000-3 . When these types are used in Structure fields, the field value is encoded
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.3.2.2 DataTypeSchemaHeadernamespace ( NamespaceIndex 0) that are not built-in types or the abstract types Number , UInteger , Integer or Enumeration shall be included in the DataSetMetaData . A Publisher should keep the namespaces
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.3.2.4 FieldMetaDatadataType field. (5) OptionSet DataTypes are either encoded as one of the concrete UInteger DataTypes or as an instance of an OptionSetType in an ExtensionObject . DataType NodeId The NodeId
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.7.1 PublisherIdsetting on the Subscriber side is contained in the DataSetReader parameters. Valid DataTypes are UInteger and String . A zero UInteger and a Null or empty String are invalid PublisherIds
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.1 PublisherIdshall be ignored and all received NetworkMessages pass the PublisherId filter. Valid DataTypes are UInteger and String
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.4.2 NetworkMessage layoutfalse. The Id of the Publisher that sent the data. Valid DataTypes are UInteger and String . The DataType is indicated by bits 0-2 of the ExtendedFlags1 . A Subscriber
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubsource is the PublisherId on a PubSubConnection (see 6.2.7.1 ). If the PublisherId is a UInteger , the UInteger value is converted to a String without leading zeros. WriterGroupName String The name
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.4.1 Message contentsource is the PublisherId on a PubSubConnection (see 6.2.7.1 ). If the PublisherId is a UInteger , the UInteger value is converted to a String without leading zeros. The value shall
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.4 Connection propertiesconfigured, the PublisherId is used as ClientID. If the PublisherId has a UInteger DataType , the UInteger value is converted to a String for the ClientID. MQTT version 5.0 allows Publishers
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.17 Variable Protocol_VersionVariable Protocol_Version This OPC UA Property , of DataType UInteger , represents the BACnet property Protocol_Version. This property identifies the major version of the BACnet protocol supported by this device
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.18 Variable Protocol_RevisionVariable Protocol_Revision This OPC UA Property , of DataType UInteger , represents the BACnet property Protocol_Revision
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.21 Variable Max_APDU_Length_AcceptedVariable Max_APDU_Length_Accepted This OPC UA Property , of DataType UInteger , represents the BACnet property Max_APDU_Length_Accepted. This property describes the maxium number of octets that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.23 Variable Max_Segments_AcceptedVariable Max_Segments_Accepted This optional OPC UA Property , of DataType UInteger , represents the BACnet property Max_Segments_Accepted. The Max_Segments_Accepted property indicates the maximum number of segments
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.24 Variable APDU_Segment_TimeoutVariable APDU_Segment_Timeout This optional OPC UA Property , of DataType UInteger , represents the BACnet property APDU_Segment_Timeout. The APDU_Segment_Timeout property indicates the amount of time
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.25 Variable APDU_TimeoutVariable APDU_Timeout This OPC UA Property , of DataType UInteger , represents the BACnet property APDU_Timeout. The APDU_Timeout property indicates the amount of time (in milliseconds) between retransmissions
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.26 Variable Number_Of_APDU_RetriesVariable Number_Of_APDU_Retries This OPC UA Property , of DataType UInteger , represents the BACnet property Number_Of_APDU_Retries. The Number_Of_APDU_Retries property indicates the maximum number
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.28 Variable Database_RevisionVariable Database_Revision This OPC UA Property , of DataType UInteger , represents the BACnet property Database_Revision. The Database_Revision property describes a logical revision number for the device database
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.15.3.4 Variable Relinquish_DefaultVariable Relinquish_Default This OPC UA Property , of DataType UInteger , represents the BACnet property Relinquish_Default. It is the default value to be used for the Present_Value when
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.15.3.5 Variable Fault_ValuesVariable Fault_Values This OPC UA Property , of DataType UInteger [], represents the BACnet property Fault_Values. The Fault_Values provide the values used by the fault state algorithm to determine
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.21.3.2 Variable Log_IntervalVariable Log_Interval This OPC UA Property , of DataType UInteger , represents the BACnet property Log_Interval. The Log_Interval value specifies a periodic value, in hundredths of a second, that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.21.3.4 Variable Interval_OffsetVariable Interval_Offset This OPC UA Property , of DataType UInteger , represents the BACnet property Interval_Offset. The Interval_Offset value indicates an offset in hundredths of seconds from the beginning
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.22.3.1 Variable COV_Resubscription_IntervalVariable COV_Resubscription_Interval This OPC UA Property , of DataType UInteger , represents the BACnet property COV_Resubscription_Interval. The COV_Resubscription_Interval specifies the time in seconds between COV resubscriptions
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelVariable Time_Synchronization_Interval This OPC UA Property , of DataType UInteger , represents the BACnet property Time_Synchronization_Interval. The Time_Synchronization_Interval specifies the periodic interval in minutes at which
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.2.2.5 Variable Interval_OffsetVariable Interval_Offset This OPC UA Property , of DataType UInteger , represents the BACnet property Interval_Offset. The Interval_Offset value indicates an offset in minutes from the period specified
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.4.2.2 Variable Max_Info_FramesVariable Max_Info_Frames This OPC UA Property , of DataType UInteger , represents the BACnet property Max_Info_Frames. The Max_Info_Frames value represents the maximum number of information frames
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.17.2.1 Variable LowLimitVariable LowLimit This OPC UA Property, of DataType UInteger , is the LowLimit parameter for the object's event algorithm. The LowLimit value represents the lower limit of the range considered
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.17.2.2 Variable HighLimitVariable HighLimit This OPC UA Property, of DataType UInteger , is the HighLimit parameter for the object's event algorithm. The HighLimit variable value represents the upper limit of the range
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.21.2.1 Variable HighLimitVariable HighLimit This OPC UA Property, of DataType UInteger , is the HighLimit parameter for the object's event algorithm. The HighLimit value represents the upper limit of the range that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.21.2.2 Variable LowLimitVariable LowLimit This OPC UA Property, of DataType UInteger , is the LowLimit parameter for the object's event algorithm. The LowLimit value represents the lower limit of the range that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.21.2.3 Variable DeadbandVariable Deadband This OPC UA Property, of DataType UInteger , is the Deadband parameter for the object's event algorithm. The Deadband value represents the deadband that is applied
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™8.17.1 OverviewOverview The DiscreteSignalVariableType is used for process variables of any data type, Integer , UInteger , Boolean , Structure etc. E.g. the data type Structure can be for aggregation of multiple values into